Transformeer je huis met de nieuwste multi-elektronica oplossingen, van intelligente verlichting tot spraakgestuurde apparaten, allemaal ontworpen om het leven gemakkelijker, veiliger en meer verbonden te maken.
SKU:V18345-2021421001
Double Acting Positioner 4-20 mA | New ABB V18345
Manufacturer: ABB
Product No.: V18345-2021421001
Product Type: Valve Positioner Module
Product Origin: Sweden
Payment:T/T, Western Union
Weight: 1700g
Shipping port: Xiamen
Warranty: 12 months
Delen
- Snelle levering
- 24/7 Ondersteuning
- Kwaliteitsborging
Beschrijving
ABB V18345-2021421001 TZIDC Electro-Pneumatic Positioner
The V18345-2021421001 (also cataloged as the V18345 Electro-Pneumatic Positioner) is a TZIDC intelligent positioner in a varnished aluminium case rated IP 65 (NEMA 4X). It accepts a 4-20 mA two-wire HART input and provides double-acting fail-safe output, with ATEX Ex II 2 G EEx ib II C T6 explosion protection. Unit weight is 1.7 kg.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | V18345-2021421001 |
| Brand | ABB |
| Product Type | TZIDC Electro-Pneumatic Positioner |
| Housing | Aluminium, IP 65 / NEMA 4X, RAL 9005 matte black |
| Weight | 1.7 kg |
| Input Signal | 4 to 20 mA, two-wire, HART via FSK module |
| Explosion Protection | ATEX Ex II 2 G EEx ib II C T6 |
| Output Function | Double acting, fail safe |
| Supply Pressure | 1.4 to 6 bar (20 to 90 psi) |
| Air Consumption | < 0.03 kg/h / 0.015 scfm |
| Pneumatic Connections | Threads G 1/4 or 1/4-18 NPT |
| Electrical Connections | Cable: Thread 1/2-14 NPT |
| Digital Input | 0-5 V DC logical 0; 11-30 V DC logical 1 |
| Digital Output | 5 to 11 V DC, DIN 19234/NAMUR |
| Position Feedback | Plug-in analog module, 4-20 mA |
Signal and Characteristic Curve Control
The V18345-2021421001 uses two-wire technology with a nominal 4-20 mA signal range, where 4 mA corresponds to 0 % and 20 mA to 100 % position. Split range operation is freely selectable with a minimum range of 20 % (3.2 mA) and a recommended range above 50 % (8.0 mA). The signal action is configurable as direct (4-20 mA = position 0-100 %) or reverse (20-4 mA = position 0-100 %). The travel characteristic is selectable as linear, equal percentage at 1:25 or 1:50, 25:1 or 50:1, or user-configurable with 20 reference points. The digital input activates a selected protective function when the 24 V DC signal drops below 10 V DC; selectable functions include move to 0 %, move to 100 %, hold last position, disable local configuration, disable local configuration and operation, or disable any access. The HART FSK module enables remote configuration through the 4-20 mA loop. The digital output follows the DIN 19234/NAMUR control circuit at 5-11 V DC.
Field Installation Guidelines
Mount the positioner to a linear actuator per DIN/IEC 534 / NAMUR or to a rotary actuator per VDI/VDE 3845 using the mechanical position indicator. Verify the hazardous area classification matches ATEX Ex II 2 G EEx ib II C T6 and confirm the input loop is intrinsically safe before wiring. Confirm the 1.7 kg unit is supported by the actuator mounting bracket. Connect the 4-20 mA HART input through the 1/2-14 NPT cable entry and the air supply through the G 1/4 or 1/4-18 NPT port. Verify supply air is dry and oil-free within 1.4 to 6 bar. For double-acting actuators, connect both pneumatic outputs and verify fail-safe action before pressurizing. Route signal wiring separately from AC power conductors and maintain the case seal for IP 65 / NEMA 4X integrity. Set split range, characteristic curve, and digital input function through the local panel or HART configuration before placing the loop in service.
Frequently Asked Questions
Q: What is the explosion protection rating of the V18345-2021421001?
A: ATEX Ex II 2 G EEx ib II C T6.
Q: What is the output function and supply pressure range?
A: Double acting, fail safe; supply pressure 1.4 to 6 bar (20 to 90 psi).
Q: What is the minimum split range and recommended split range?
A: Minimum range 20 % (3.2 mA); recommended range above 50 % (8.0 mA).
Aanvullende specificaties
- Zilver
Scalar (V/f)
Vector
Op netstroom
Koopgids
- Bevestig het exacte model, onderdeelnummer en specificaties voordat u bestelt.
- Zorg voor compatibiliteit met uw huidige machines of besturingssystemen.
- Neem contact op via sale@etowonauto.com of +8617859788089 voor technische ondersteuning.
- Bekijk de leveringsopties, doorlooptijden en verzendvereisten.
- Volg de instructies van de fabrikant en de beste praktijken tijdens de installatie.
Verzending en Retourneren
Voorraadartikelen worden doorgaans dezelfde werkdag verzonden. Voor producten die momenteel niet op voorraad zijn, kunnen de verzendtijden variëren afhankelijk van de beschikbaarheid. Internationale verzending is mogelijk, en de verzendkosten worden berekend op basis van bestemming, gewicht en gekozen vervoerder.
Retourzendingen worden geaccepteerd binnen 30 dagen na ontvangst, mits de artikelen ongebruikt en in originele staat zijn. De kosten voor retourzending zijn voor rekening van de klant. Neem alstublieft contact met ons op voordat u een artikel retourneert om een retourautorisatie te ontvangen.
Voor meer details kunt u onze Verzend- en Retourbeleid raadplegen.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Snelle verzending
Originele onderdelen voor industriële automatisering beschikbaar voor snelle verzending wereldwijd.
-
Eenvoudige Retourzendingen
30 dagen retourrecht met 12 maanden garantie voor betrouwbare nazorgbescherming.
-
24/7 ondersteuning
Responsieve professionele ondersteuning om stabiele en efficiënte bedrijfsvoering te behouden.
-
Echt & Origineel
100% authentiek, rechtstreeks afkomstig van vertrouwde fabrikanten van industriële automatisering.
Technische & Koopgids
-
What Logic Changes Cut SIS False Trips by 94%?
This article examines practical logic modification and parameter tuning methods for ABB 800xA HI SIL3 safety ins...
-
Why Do FTE Redundancy Failovers Lock Up in DCS?
Honeywell FTE delivers sub-500 ms failover for Experion PKS, yet field records show 38% of outages stem from installa...
-
How Does the Bently Nevada 3500/42M Vibration Module Drift?
This technical guide examines the Bently Nevada 3500/42M vibration module within industrial automation architect...
-
What Causes IC694MDL Fault Codes in GE RX3i PLC Systems?
This guide explains GE RX3i IC694MDL discrete I/O fault codes, key electrical parameters, ESD and torque requirements...
-
What CFC Rules Cut PCS7 Batch Abort Rates Fast?
This article presents enforceable CFC programming governance rules for Siemens PCS7 DCS batch plants, covering b...
-
What Makes the 1769-L3ER Ideal for Compact Skid Automation?
This guide explains how the Allen-Bradley 1769 CompactLogix L3ER bridges the gap between micro PLCs and large DC...
