Transformeer je huis met de nieuwste multi-elektronica oplossingen, van intelligente verlichting tot spraakgestuurde apparaten, allemaal ontworpen om het leven gemakkelijker, veiliger en meer verbonden te maken.
SKU:VFD17AMS43EFSAA
Delta VFD17AMS43EFSAA Variable Frequency Drive 7.5kW 17A
Manufacturer: Delta
Product No.: VFD17AMS43EFSAA
Product Type: AC Drive
Product Origin: CN
Payment:T/T, Western Union
Weight: 2500g
Shipping port: Xiamen
Warranty: 12 months
Delen
- Snelle levering
- 24/7 Ondersteuning
- Kwaliteitsborging
Beschrijving
Product Overview
The Delta VFD17AMS43EFSAA is a high-performance member of the MS300 series, Delta's premier line of compact, standard vector control drives. This specific unit is tailored for 480V three-phase industrial grids, delivering a consistent 7.5 kW (10 HP) of power. With a net weight of approximately 2.50 kg (5.51 lbs), the VFD17AMS43EFSAA offers an exceptional power-to-size ratio, providing a rated output current of 17 A to drive demanding industrial motors with precision and ease.
Core Technical Advantages
Operational economy is a major benefit of the VFD17AMS43EFSAA. It features an ultra-low standby power loss of only 8 W, making it one of the more energy-efficient drives in its class. Built for reliability, it maintains a maximum operating temperature of 40 °C. The drive's advanced architecture ensures that power losses are minimized across all load conditions; even at 90% frequency and full 100% current, the relative power loss remains below 2%, ensuring that the unit runs cool and reduces the cooling load on your electrical cabinet.
Technical Specifications
| Parameter | Specification Details |
|---|---|
| Model Name | VFD17AMS43EFSAA |
| Rated Power Output | 7.5 kW (10 HP) |
| Rated Output Current | 17 A |
| Supply Voltage | 380...480V AC (3-Phase) |
| Apparent Power | 13 kVA |
| Frequency Range | 50/60 Hz |
| Standby Loss | 8 Watts |
Efficiency & Load Performance
The VFD17AMS43EFSAA is designed for high-efficiency throughput. Below is the detailed power loss profile based on operational frequency and current load:
- 100% Load Performance: Power loss is 213.4 W at 0% frequency, rising to 251.8 W at 90% frequency.
- Partial Load (50% Current): Efficiency remains high at half-load, with losses between 147.9 W and 163.1 W.
- Low Load (25% Current): At quarter-load, the drive is highly efficient with a relative power loss of only 1.0%.
Installation & Engineering Guide
To ensure optimal performance of the VFD17AMS43EFSAA, mount the drive vertically to take advantage of natural airflow, supplemented by the internal cooling system. It is designed for 380-480V AC inputs and includes an integrated STO (Safe Torque Off) function to enhance machine safety. The MS300 series supports a variety of communication cards, including EtherCAT, Profibus, and DeviceNet, making it easy to integrate into existing industrial networks. For applications involving high-speed switching, use shielded cables to maintain signal integrity and comply with EMC standards.
Engineering Advantages
The Delta MS300 series provides versatile motor control, supporting both Induction Motors (IM) and Permanent Magnet Motors (PM). The VFD17AMS43EFSAA features a built-in PLC for basic logic programming, which can often eliminate the need for an external micro-PLC in simple automation tasks. Its compact dimensions allow for side-by-side installation, maximizing cabinet space. High-speed pulse inputs and a built-in USB port for quick configuration make it a favorite for system integrators in the textile, food packaging, and machine tool industries.
Technical FAQs
Q1: What is the benefit of the 13 kVA apparent power rating?
A1: The 13 kVA rating indicates the total electrical capacity the drive can supply, covering both the active power (kW) and reactive power required by the motor's magnetic field.
Q2: Can this drive operate in high-humidity environments?
A2: Yes, provided the environment is non-condensing. For extreme conditions, ensure the drive is housed in an appropriately rated (IP66/NEMA 4X) enclosure.
Q3: Does the VFD17AMS43EFSAA support high-frequency output?
A3: Yes, the MS300 series can support high-speed models capable of reaching up to 599 Hz or 1500 Hz depending on the firmware version, suitable for high-speed spindle applications.
Aanvullende specificaties
- Zwart
- Grijs
Scalar (V/f)
Vector
Op netstroom
Koopgids
- Bevestig het exacte model, onderdeelnummer en specificaties voordat u bestelt.
- Zorg voor compatibiliteit met uw huidige machines of besturingssystemen.
- Neem contact op via sale@etowonauto.com of +8617859788089 voor technische ondersteuning.
- Bekijk de leveringsopties, doorlooptijden en verzendvereisten.
- Volg de instructies van de fabrikant en de beste praktijken tijdens de installatie.
Verzending en Retourneren
Voorraadartikelen worden doorgaans dezelfde werkdag verzonden. Voor producten die momenteel niet op voorraad zijn, kunnen de verzendtijden variëren afhankelijk van de beschikbaarheid. Internationale verzending is mogelijk, en de verzendkosten worden berekend op basis van bestemming, gewicht en gekozen vervoerder.
Retourzendingen worden geaccepteerd binnen 30 dagen na ontvangst, mits de artikelen ongebruikt en in originele staat zijn. De kosten voor retourzending zijn voor rekening van de klant. Neem alstublieft contact met ons op voordat u een artikel retourneert om een retourautorisatie te ontvangen.
Voor meer details kunt u onze Verzend- en Retourbeleid raadplegen.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Snelle verzending
Originele onderdelen voor industriële automatisering beschikbaar voor snelle verzending wereldwijd.
-
Eenvoudige Retourzendingen
30 dagen retourrecht met 12 maanden garantie voor betrouwbare nazorgbescherming.
-
24/7 ondersteuning
Responsieve professionele ondersteuning om stabiele en efficiënte bedrijfsvoering te behouden.
-
Echt & Origineel
100% authentiek, rechtstreeks afkomstig van vertrouwde fabrikanten van industriële automatisering.
Technische & Koopgids
-
Waarom is een failover van 50 ms cruciaal voor slimme fabrieken in Industrie 4.0?
Dit artikel onderzoekt het ABB DCS full-link redundantieontwerp voor farmaceutische productie onder GMP- en Industry ...
-
Wat zijn de hoofdoorzaken van intermitterende TSI-communicatiefouten?
Dit artikel biedt een kwantitatieve probleemoplossingsmethode voor communicatieproblemen tussen GE Fanuc PLC en Bentl...
-
How to Secure Emerson DeltaV DCS Under Industry 4.0?
This article presents practical Emerson DeltaV DCS hardening strategies aligned with IEC 62443 standards for process ...
-
Is Your Metallurgical Plant Losing Millions to Hidden Energy Waste?
Metallurgical plants waste substantial energy due to fragmented PLC and DCS architectures that cannot share real-time...
-
How to Migrate GE Fanuc to Allen-Bradley Without Production Downtime?
This article provides a data-driven migration guide from GE Fanuc to Allen-Bradley PLCs for discrete manufacturing. I...
-
How Can Bently Nevada Kits Cut Centrifugal Machinery Downtime?
This article shows how Bently Nevada turnkey kits reduce unplanned downtime for centrifugal compressors and fans. It ...