Transformeer je huis met de nieuwste multi-elektronica oplossingen, van intelligente verlichting tot spraakgestuurde apparaten, allemaal ontworpen om het leven gemakkelijker, veiliger en meer verbonden te maken.
SKU:200350-02-00-01
200350-02-00-01 Bently Nevada Hazardous Area Accelerometer
Manufacturer: Bently Nevada
Product No.: 200350-02-00-01
Product Type: Accelerometer
Product Origin: USA
Payment:T/T, Western Union
Weight: 51g
Shipping port: Xiamen
Warranty: 12 months
Delen
- Snelle levering
- 24/7 Ondersteuning
- Kwaliteitsborging
Beschrijving
Product Overview
The 200350-02-00-01 is a premium seismic accelerometer designed by Bently Nevada for high-fidelity vibration monitoring in classified hazardous locations. Utilizing advanced shear-mode ceramic sensing technology, this transducer provides superior immunity to thermal transients and base strain, ensuring that your vibration data remains accurate even in fluctuating industrial conditions. With a 10 kHz frequency range, it is optimized for detecting early mechanical failures in high-speed turbines and compressors, allowing for proactive maintenance in environments where safety and reliability are non-negotiable.
Technical Configuration
The 200350-02-00-01 is specialized for international safety and mechanical standards. The "02" suffix denotes the inclusion of a 1/4-28 to M8 x 1.25 stainless steel adapter stud, facilitating installation on metric-threaded machinery. The "00" tolerance provides a calibrated 100 mV/g (±20%) output, while the critical "01" agency approval option certifies the unit for use under CSA, ATEX, and IECEx regulations. The sensor is built with a top-exit 2-pin Mil-C-5015 connector and a rugged 304 stainless steel housing, ensuring long-term hermetic integrity in the most challenging field conditions.
Technical Specifications
| Parameter | Specification |
|---|---|
| Sensitivity | 100 mV/g ± 20% (10.2 mV/m/s²) |
| Agency Approvals | CSA, ATEX, IECEx (Intrinsically Safe) |
| Frequency Range | 0.5 Hz to 10,000 Hz (30 – 600,000 cpm) |
| Weight | 0.051 kg (1.8 oz) |
| Operating Temp | -54°C to +121°C (-65°F to +250°F) |
| Enclosure Rating | IP68 / Welded Hermetic |
Installation & Maintenance Guide
To achieve the specified frequency response with the 200350-02-00-01, the mounting surface must be clean and machined flat. The M8 x 1.25 stainless steel stud should be torqued between 2.7 and 6.8 N-m (2 to 5 ft-lb) to ensure a rigid mechanical path. In hazardous area installations, it is mandatory to use the sensor in conjunction with an appropriately rated intrinsic safety barrier. While the IP68 rating allows for operation in 100% condensing humidity, the electrical connector should remain clean and dry during installation to maintain an isolation resistance of >10^8 ohms. A Certificate of Origin (COO) is available upon request for customs compliance.
Engineering Advantages
The 200350-02-00-01 excels in precision diagnostics due to its tight ±1% amplitude linearity and low transverse sensitivity (≤7%). The ceramic shear geometry significantly reduces error caused by machine base strain, a common issue in large industrial pumps and motors. Furthermore, the sensor features a rapid 2.0-second settling time and exceptional shock survivability of 5,000g peak, making it a robust choice for monitoring reciprocating machinery or assets prone to transient impact events.
Technical FAQs
Q1: What does the "01" agency approval option cover?
A1: The "01" option provides certifications for CSA, ATEX, and IECEx, making the 200350-02-00-01 suitable for intrinsically safe installations in Zone 0, 1, or 2, as well as various North American classes and divisions.
Q2: Can this sensor monitor very low-speed machinery?
A2: Yes, with a frequency response starting at 0.5 Hz (30 cpm), it can detect low-frequency vibrations typical of hydroelectric turbines or large industrial fans.
Q3: Why is the housing made of welded stainless steel?
A3: The welded hermetic construction provides an IP68 rating, protecting the internal ceramic elements from chemical ingress and moisture, which is critical for long-term reliability in harsh oil and gas environments.
Aanvullende specificaties
Scalar (V/f)
Vector
Op netstroom
Koopgids
- Bevestig het exacte model, onderdeelnummer en specificaties voordat u bestelt.
- Zorg voor compatibiliteit met uw huidige machines of besturingssystemen.
- Neem contact op via sale@etowonauto.com of +8617859788089 voor technische ondersteuning.
- Bekijk de leveringsopties, doorlooptijden en verzendvereisten.
- Volg de instructies van de fabrikant en de beste praktijken tijdens de installatie.
Verzending en Retourneren
Voorraadartikelen worden doorgaans dezelfde werkdag verzonden. Voor producten die momenteel niet op voorraad zijn, kunnen de verzendtijden variëren afhankelijk van de beschikbaarheid. Internationale verzending is mogelijk, en de verzendkosten worden berekend op basis van bestemming, gewicht en gekozen vervoerder.
Retourzendingen worden geaccepteerd binnen 30 dagen na ontvangst, mits de artikelen ongebruikt en in originele staat zijn. De kosten voor retourzending zijn voor rekening van de klant. Neem alstublieft contact met ons op voordat u een artikel retourneert om een retourautorisatie te ontvangen.
Voor meer details kunt u onze Verzend- en Retourbeleid raadplegen.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Snelle verzending
Originele onderdelen voor industriële automatisering beschikbaar voor snelle verzending wereldwijd.
-
Eenvoudige Retourzendingen
30 dagen retourrecht met 12 maanden garantie voor betrouwbare nazorgbescherming.
-
24/7 ondersteuning
Responsieve professionele ondersteuning om stabiele en efficiënte bedrijfsvoering te behouden.
-
Echt & Origineel
100% authentiek, rechtstreeks afkomstig van vertrouwde fabrikanten van industriële automatisering.
Technische & Koopgids
-
Waarom is een failover van 50 ms cruciaal voor slimme fabrieken in Industrie 4.0?
Dit artikel onderzoekt het ABB DCS full-link redundantieontwerp voor farmaceutische productie onder GMP- en Industry ...
-
Wat zijn de hoofdoorzaken van intermitterende TSI-communicatiefouten?
Dit artikel biedt een kwantitatieve probleemoplossingsmethode voor communicatieproblemen tussen GE Fanuc PLC en Bentl...
-
How to Secure Emerson DeltaV DCS Under Industry 4.0?
This article presents practical Emerson DeltaV DCS hardening strategies aligned with IEC 62443 standards for process ...
-
Is Your Metallurgical Plant Losing Millions to Hidden Energy Waste?
Metallurgical plants waste substantial energy due to fragmented PLC and DCS architectures that cannot share real-time...
-
How to Migrate GE Fanuc to Allen-Bradley Without Production Downtime?
This article provides a data-driven migration guide from GE Fanuc to Allen-Bradley PLCs for discrete manufacturing. I...
-
How Can Bently Nevada Kits Cut Centrifugal Machinery Downtime?
This article shows how Bently Nevada turnkey kits reduce unplanned downtime for centrifugal compressors and fans. It ...