Canza gidanka da sabbin hanyoyin na’urorin lantarki masu yawa, daga hasken wuta mai hankali zuwa inganta ayyukanka da Bently Nevada 3500 Monitoring System, wanda ke ba da sa ido a ainihin lokaci kan girgiza da yanayin na’urorin injina don hana gazawa da ƙara lokacin aiki, da na’urorin da ake sarrafa su da murya duk an ƙera su ne don sauƙaƙa rayuwa, ƙara tsaro, da ƙarfafa haɗin kai.
SKU:8440-2052
Woodward 8440-2052 easYgen 3200 Series Genset Control
Manufacturer: Woodward
Product No.: 8440-2052
Product Type: Control Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 2300g
Shipping port: Xiamen
Warranty: 12 months
Raba
- Isarwa Cikin Gaggawa
- Tallafi na awa 24 a rana, kwana 7 a mako
- Tabbacin Inganci
Bayani
Product Overview
The Woodward 8440-2052 is an easYgen-3200-5/P2 genset controller with built in operator interface and breaker control. It handles load sharing, AMF, and standby operation for up to 32 gensets. Package 2 adds three freely configurable PID controllers.
Key Specifications
| Parameter | Value |
|---|---|
| Power Supply | 12/24 VDC (8 to 40 VDC) |
| Analog Inputs | 3 configurable, non isolated, freely scalable |
| CT Inputs | 5 A |
| Discrete I/Os | Up to 12 configurable |
| External I/Os | 32 discrete, 16 analog in, 4 analog out via CANopen |
| Alarm Outputs | 12 discrete (10 configurable) |
| Measuring Frequency | 50/60 Hz (40 to 85 Hz) |
| Windings | 3p 3w, 3p 4w, 1p 2w, 1p 3w |
| Intrinsic Consumption | Max. 17 W |
| Contact Material | AgCdO |
| Weight | Approx. 2.3 kg |
| Front Panel | 282W x 216H x 96D mm |
| Back Panel | 250W x 227H x 50D mm |
Installation & Advantages
Mounting: Front panel mounting in plastic housing.
Speed Input: Magnetic or switching pickup.
Protection: Configurable setpoints for generator, engine, and mains.
Scalability: Supports single or multiple unit operation up to 32 gensets.
FAQs
Q1: What is the difference between 3200 and 3200-P2?
A1: P2 adds three freely configurable PID controllers for advanced process control.
Q2: How many external I/Os are supported?
A2: 32 discrete, 16 analog inputs, and 4 analog outputs via CANopen.
Q3: What is the power supply range?
A3: 12/24 VDC nominal, operating from 8 to 40 VDC.
Ƙarin ƙayyadaddun bayanai
Sikeli (V/f)
Vector
mai amfani da wutar AC
Jagorar Sayi
- Tabbatar da ainihin samfurin, lambar ɓangare, da ƙayyadaddun bayanai kafin yin oda.
- Tabbatar da jituwa da injin ko tsarin kula da kake amfani da su a yanzu.
- Tuntuɓe mu ta sale@etowonauto.com ko +8617859788089 don taimakon fasaha.
- Duba zaɓuɓɓukan isarwa, lokacin jagora, da buƙatun jigilar kaya.
- Bi umarnin masana’anta da mafi kyawun hanyoyin aiki yayin girkawa.
Isarwa da Mayar da Kaya
Kayayyakin da ke cikin sito yawanci ana tura su a cikin wannan ranar aikin. Ga kayayyakin da ba sa cikin sito a yanzu, lokacin tura su na iya bambanta bisa ga samuwa. Ana ba da jigilar kaya zuwa ƙasashen waje, kuma ana ƙididdige kuɗin jigila bisa wurin da ake aikawa, nauyi, da kamfanin sufuri da aka zaɓa.
Ana karɓar mayar da kaya cikin kwanaki 30 bayan karɓa, muddin kayan ba a yi amfani da su ba kuma suna cikin yanayin da suka fito daga masana’anta. Kuɗin jigilar mayar da kaya nauyi ne a kan abokin ciniki. Da fatan za a tuntube mu kafin ku mayar da duk wani kaya domin samun izinin mayarwa.
Don ƙarin bayani, don Allah ku duba Manufar Jigila & Mayar da Kaya.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Isarwa cikin gaggawa
Sassan kayan otomeshan na masana’antu na ainihi suna nan a shirye don aikawa cikin gaggawa a ko’ina cikin duniya.
-
Mayar da kaya cikin sauƙi
Tallafin mayar da kaya na kwanaki 30 tare da garantin watanni 12 don tabbatacciyar kariya bayan saye.
-
Taimako a kowane lokaci (24/7)
Tallafin ƙwararru mai saurin amsawa don taimakawa kiyaye ayyuka cikin kwanciyar hankali da inganci.
-
Na Gaskiya & Asali
Kashi 100% na asali ne, ana samar da su kai tsaye daga amintattun masana’antun kayan sarrafa masana’antu.
Jagorar Fasaha da Siyarwa
-
Why Does PCS7 OS Server Redundancy Fail Over?
This guide explains how to diagnose and repair Siemens PCS7 OS server redundancy failover anomalies using quantified ...
-
How Do You Recover a Bricked Allen-Bradley PLC?
This article explains how industrial automation teams classify bricked Allen-Bradley Logix controllers, validate firm...
-
How Can You Prevent Historian Data Loss During Experion PKS Migration?
This article presents a measurable playbook for protecting Honeywell Experion historian data during server and H...
-
How Do MTL Barriers and DCS IO Cards Affect Loop Voltage?
Intrinsic safety circuits protect hazardous process areas, yet loop impedance budgeting often receives far less atten...
-
How Can You Tune GE RX3i and RX7i Ethernet for Heavy Industry?
Intermittent Ethernet timeouts on GE RX3i and RX7i controllers are among the hardest faults in heavy process plants, ...
-
Why Does FCS Redundancy Not Protect Your HIS Configuration?
This article examines the operational risks of Yokogawa CENTUM VP HIS lockups and explains why FCS controller re...
