Canza gidanka da sabbin hanyoyin na’urorin lantarki masu yawa, daga hasken wuta mai hankali zuwa inganta ayyukanka da Bently Nevada 3500 Monitoring System, wanda ke ba da sa ido a ainihin lokaci kan girgiza da yanayin na’urorin injina don hana gazawa da ƙara lokacin aiki, da na’urorin da ake sarrafa su da murya duk an ƙera su ne don sauƙaƙa rayuwa, ƙara tsaro, da ƙarfafa haɗin kai.
SKU:TSXASZ401
TSXASZ401 Schneider | 4-Channel Analog Output | 0-10V
Manufacturer: Schneider
Product No.: TSXASZ401
Product Type: Analog Output Module
Product Origin: FR
Payment:T/T, Western Union
Weight: 200g
Shipping port: Xiamen
Warranty: 12 months
Raba
- Isarwa Cikin Gaggawa
- Tallafi na awa 24 a rana, kwana 7 a mako
- Tabbacin Inganci
Bayani
Product Overview
The Schneider TSXASZ401 is an analog output module designed for the Modicon TSX Micro automation platform. It provides 4 output channels supporting 0-10V and ±10V signal types with an 11-bit resolution. A fast 400µs response time suits applications requiring prompt signal processing. Weighing 0.2 kg, this compact module integrates easily into existing TSX Micro PLC systems.
Technical Configuration
This module delivers 11-bit analog-to-digital conversion for both 0-10V and ±10V output ranges. Output load requirement is a minimum of 2 Ohms for broad device compatibility. Integrated short-circuit protection safeguards connected equipment. Temperature drift is limited to 0.096% per 10°C change, ensuring stable output across varying conditions.
Technical Specifications
| Parameter | Value |
|---|---|
| Manufacturer | Schneider Electric |
| Product Line | Modicon TSX Micro |
| Part Number | TSXASZ401 |
| EAN | 3389110604535 |
| Number of Channels | 4 |
| Output Type | 0...10 V, +/- 10 V |
| A/D Conversion | 11 bits (0...10 V), 11 bits + sign (+/- 10 V) |
| Response Time | 400 µs |
| Output Load | >= 2 Ohms |
| Protection Type | Short-circuit |
| Temperature Drift | 0.096 %/10 °C |
| Current Consumption | 90 mA |
| Isolation Voltage | 1000 V AC |
| Net Weight | 0.2 kg |
| Compliance | RoHS |
Installation Guide
Install the module into a compatible TSX Micro PLC rack slot. Verify the minimum output load of 2 Ohms before connecting field devices. Maintain proper grounding to preserve the 1000VAC isolation rating. Route analog signal wiring away from high-voltage cables to minimize noise. Confirm short-circuit protection is active by testing output channels during commissioning.
Engineering Advantages
The 400µs response time enables fast closed-loop control in dynamic processes. Dual output ranges (0-10V and ±10V) provide flexibility across different actuator types. The 11-bit resolution delivers precise signal output for accurate positioning and speed control. Integrated short-circuit protection reduces downtime risk. RoHS compliance supports environmentally responsible installations.
Technical FAQs
Q1: What output voltage ranges does the TSXASZ401 support?
A1: This module provides 4 channels supporting both 0-10V and ±10V output types with 11-bit resolution.
Q2: What is the minimum output load requirement?
A2: The TSXASZ401 requires a minimum output load of 2 Ohms for proper operation.
Q3: What isolation voltage does this module provide?
A3: The module offers 1000VAC isolation voltage, supporting use in demanding industrial applications.
Ƙarin ƙayyadaddun bayanai
Sikeli (V/f)
Vector
mai amfani da wutar AC
Jagorar Sayi
- Tabbatar da ainihin samfurin, lambar ɓangare, da ƙayyadaddun bayanai kafin yin oda.
- Tabbatar da jituwa da injin ko tsarin kula da kake amfani da su a yanzu.
- Tuntuɓe mu ta sale@etowonauto.com ko +8617859788089 don taimakon fasaha.
- Duba zaɓuɓɓukan isarwa, lokacin jagora, da buƙatun jigilar kaya.
- Bi umarnin masana’anta da mafi kyawun hanyoyin aiki yayin girkawa.
Isarwa da Mayar da Kaya
Kayayyakin da ke cikin sito yawanci ana tura su a cikin wannan ranar aikin. Ga kayayyakin da ba sa cikin sito a yanzu, lokacin tura su na iya bambanta bisa ga samuwa. Ana ba da jigilar kaya zuwa ƙasashen waje, kuma ana ƙididdige kuɗin jigila bisa wurin da ake aikawa, nauyi, da kamfanin sufuri da aka zaɓa.
Ana karɓar mayar da kaya cikin kwanaki 30 bayan karɓa, muddin kayan ba a yi amfani da su ba kuma suna cikin yanayin da suka fito daga masana’anta. Kuɗin jigilar mayar da kaya nauyi ne a kan abokin ciniki. Da fatan za a tuntube mu kafin ku mayar da duk wani kaya domin samun izinin mayarwa.
Don ƙarin bayani, don Allah ku duba Manufar Jigila & Mayar da Kaya.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Isarwa cikin gaggawa
Sassan kayan otomeshan na masana’antu na ainihi suna nan a shirye don aikawa cikin gaggawa a ko’ina cikin duniya.
-
Mayar da kaya cikin sauƙi
Tallafin mayar da kaya na kwanaki 30 tare da garantin watanni 12 don tabbatacciyar kariya bayan saye.
-
Taimako a kowane lokaci (24/7)
Tallafin ƙwararru mai saurin amsawa don taimakawa kiyaye ayyuka cikin kwanciyar hankali da inganci.
-
Na Gaskiya & Asali
Kashi 100% na asali ne, ana samar da su kai tsaye daga amintattun masana’antun kayan sarrafa masana’antu.
Jagorar Fasaha da Siyarwa
-
What Makes ABB Freelance AC800F Ideal for Mid-Size Plants?
The ABB Freelance AC800F combines PLC sequential logic and DCS regulatory control in a single controller, serving pla...
-
What Makes GE Mark VIe the Top Turbine Control DCS?
GE Mark VIe is a high-performance turbine control DCS built for gas and steam power plants. It combines fast scan cyc...
-
What Makes Emerson DeltaV M-Series Ideal for Oil & Gas DCS Control?
Emerson's DeltaV M-Series controller delivers reliable regulatory control for oil and gas assets through MQ and MX va...
-
What Makes Siemens PCS 7 AS410 Ideal for Chemical DCS?
Siemens PCS 7 with the AS410 automation station delivers high availability for continuous chemical manufacturing. Thi...
-
What Causes Most ABB AC800M Migration Failures?
ABB AC800M controllers have run for 12 to 18 years in many plants, and spare part lead times now reach 16 weeks. This...
-
How to Migrate Honeywell TDC3000 to Experion PKS?
This guide explains how process plants can migrate aging Honeywell TDC3000 DCS systems to Experion PKS C300 through p...
