Canza gidanka da sabbin hanyoyin na’urorin lantarki masu yawa, daga hasken wuta mai hankali zuwa inganta ayyukanka da Bently Nevada 3500 Monitoring System, wanda ke ba da sa ido a ainihin lokaci kan girgiza da yanayin na’urorin injina don hana gazawa da ƙara lokacin aiki, da na’urorin da ake sarrafa su da murya duk an ƙera su ne don sauƙaƙa rayuwa, ƙara tsaro, da ƙarfafa haɗin kai.
SKU:6ES7421-7DH00-0AB0
Siemens | 6ES7421-7DH00-0AB0 SM 421 Diagnostics Alarm
Manufacturer: Siemens
Product No.: 6ES7421-7DH00-0AB0
Product Type: Digital Input Module
Product Origin: DE
Payment:T/T, Western Union
Weight: 600g
Shipping port: Xiamen
Warranty: 12 months
Raba
- Isarwa Cikin Gaggawa
- Tallafi na awa 24 a rana, kwana 7 a mako
- Tabbacin Inganci
Bayani
Siemens 6ES7421-7DH00-0AB0 SIMATIC S7-400 SM 421 Digital Input Module
Siemens 6ES7421-7DH00-0AB0 is a SIMATIC S7-400 SM 421 digital input module with 16 isolated UC 24-60V inputs. Features parameterizable input delay, wire-break monitoring, diagnostics, and alarms. Weight approximately 600 g.
Key Specifications
| Parameter | Value |
|---|---|
| Article No. | 6ES7421-7DH00-0AB0 |
| Product Type | Digital Input Module SM 421 |
| Number of Inputs | 16 |
| Input Voltage Type | AC/DC (UC) |
| Rated Value | 24V to 60V UC (47-63 Hz) |
| Backplane Current (5V) | 150 mA max |
| Power Loss | 8W typ (3.5W @ 24V, 6.5W @ 48V, 8.0W @ 60V) |
| Weight | Approximately 600 g |
Input Specifications
| Parameter | Value |
|---|---|
| Signal "0" Voltage | -6 to +6V DC / 0-5V AC |
| Signal "1" Voltage | 15-72V DC / -15 to -72V DC / 15-60V AC |
| Input Current "1" | 4 to 10 mA typical |
| Input Delay | Parameterizable: 0.5 / 3 / 10 / 20 ms |
| Cable Length (Shielded) | 1000 m max |
| Cable Length (Unshielded) | 600 m max (3/10/20 ms), 100 m (0.5 ms) |
Diagnostics & Isolation
| Parameter | Value |
|---|---|
| Diagnostics Function | Yes, parameterizable |
| Wire-Break Monitoring | Yes, I > 0.7 mA |
| Channel Separation | Yes, between each channel |
| Isolation Test Voltage | 1500 VAC |
| 2-Wire Sensor Quiescent Current | 0.5 to 2 mA max |
Dimensions
| Parameter | Value |
|---|---|
| Width | 25 mm |
| Height | 290 mm |
| Depth | 210 mm |
FAQs
Q1: What input voltage range does the 6ES7421-7DH00-0AB0 support?
A1: UC 24V to 60V AC/DC at 47-63 Hz.
Q2: What input delay settings are available?
A2: Parameterizable at 0.5, 3, 10, or 20 ms.
Q3: How are the channels isolated?
A3: Each channel is individually isolated, tested at 1500 VAC.
Ƙarin ƙayyadaddun bayanai
Sikeli (V/f)
Vector
mai amfani da wutar AC
Jagorar Sayi
- Tabbatar da ainihin samfurin, lambar ɓangare, da ƙayyadaddun bayanai kafin yin oda.
- Tabbatar da jituwa da injin ko tsarin kula da kake amfani da su a yanzu.
- Tuntuɓe mu ta sale@etowonauto.com ko +8617859788089 don taimakon fasaha.
- Duba zaɓuɓɓukan isarwa, lokacin jagora, da buƙatun jigilar kaya.
- Bi umarnin masana’anta da mafi kyawun hanyoyin aiki yayin girkawa.
Isarwa da Mayar da Kaya
Kayayyakin da ke cikin sito yawanci ana tura su a cikin wannan ranar aikin. Ga kayayyakin da ba sa cikin sito a yanzu, lokacin tura su na iya bambanta bisa ga samuwa. Ana ba da jigilar kaya zuwa ƙasashen waje, kuma ana ƙididdige kuɗin jigila bisa wurin da ake aikawa, nauyi, da kamfanin sufuri da aka zaɓa.
Ana karɓar mayar da kaya cikin kwanaki 30 bayan karɓa, muddin kayan ba a yi amfani da su ba kuma suna cikin yanayin da suka fito daga masana’anta. Kuɗin jigilar mayar da kaya nauyi ne a kan abokin ciniki. Da fatan za a tuntube mu kafin ku mayar da duk wani kaya domin samun izinin mayarwa.
Don ƙarin bayani, don Allah ku duba Manufar Jigila & Mayar da Kaya.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Isarwa cikin gaggawa
Sassan kayan otomeshan na masana’antu na ainihi suna nan a shirye don aikawa cikin gaggawa a ko’ina cikin duniya.
-
Mayar da kaya cikin sauƙi
Tallafin mayar da kaya na kwanaki 30 tare da garantin watanni 12 don tabbatacciyar kariya bayan saye.
-
Taimako a kowane lokaci (24/7)
Tallafin ƙwararru mai saurin amsawa don taimakawa kiyaye ayyuka cikin kwanciyar hankali da inganci.
-
Na Gaskiya & Asali
Kashi 100% na asali ne, ana samar da su kai tsaye daga amintattun masana’antun kayan sarrafa masana’antu.
Jagorar Fasaha da Siyarwa
-
How Can You Prevent Historian Data Loss During Experion PKS Migration?
This article presents a measurable playbook for protecting Honeywell Experion historian data during server and H...
-
How Do MTL Barriers and DCS IO Cards Affect Loop Voltage?
Intrinsic safety circuits protect hazardous process areas, yet loop impedance budgeting often receives far less atten...
-
How Can You Tune GE RX3i and RX7i Ethernet for Heavy Industry?
Intermittent Ethernet timeouts on GE RX3i and RX7i controllers are among the hardest faults in heavy process plants, ...
-
Why Does FCS Redundancy Not Protect Your HIS Configuration?
This article examines the operational risks of Yokogawa CENTUM VP HIS lockups and explains why FCS controller re...
-
How Does 1756 Analog I/O Calibration Drift Affect PLC Accuracy?
This article examines calibration drift in Allen-Bradley ControlLogix 1756 analog I/O modules, presenting quanti...
-
Why Do 31% of ABB 800xA S800 IO Hot Swaps Fail in DCS Systems?
ABB 800xA S800 hot swap failures rarely stem from defective hardware. Field data from 142 card replacement jobs shows...