Canza gidanka da sabbin hanyoyin na’urorin lantarki masu yawa, daga hasken wuta mai hankali zuwa inganta ayyukanka da Bently Nevada 3500 Monitoring System, wanda ke ba da sa ido a ainihin lokaci kan girgiza da yanayin na’urorin injina don hana gazawa da ƙara lokacin aiki, da na’urorin da ake sarrafa su da murya duk an ƙera su ne don sauƙaƙa rayuwa, ƙara tsaro, da ƙarfafa haɗin kai.
SKU:TSXASY410
Schneider Electric TSXASY410 4 Channel Analog Output
Manufacturer: Schneider
Product No.: TSXASY410
Product Type: Analog Output Module
Product Origin: FR
Payment:T/T, Western Union
Weight: 350g
Shipping port: Xiamen
Warranty: 12 months
Raba
- Isarwa Cikin Gaggawa
- Tallafi na awa 24 a rana, kwana 7 a mako
- Tabbacin Inganci
Bayani
Schneider Electric TSXASY410 Modicon Analog Output Module
Schneider Electric TSXASY410 | Analog output module for the Modicon Premium and TSX Micro automation platforms. Provides 4 analog output channels with selectable current (0-20 mA, 4-20 mA) or voltage (±10 V) output. 1500 Vrms channel-to-channel and channel-to-bus isolation. Screw terminal block connection. Weight: 0.35 kg (0.77 lb).
Key Features
4 analog output channels. Selectable current (0-20 mA, 4-20 mA) or voltage (±10 V) output. 11-bit + sign analog/digital conversion. 2.5 ms conversion time. 10.25 µA resolution (current), 5.12 mV resolution (voltage). 1500 Vrms isolation between channels and bus. Overload and short-circuit protection. Screw terminal block connection. CE marked. Made in France.
Technical Specifications
| Manufacturer | Schneider Electric |
| Part Number | TSXASY410 |
| Product Line | TSX Micro PLCs / Modicon Premium |
| Product Type | Analog Output Module |
| Number of Channels | 4 |
| Output Type | Current 0-20 mA, 4-20 mA; Voltage ±10 V |
| Analog/Digital Conversion | 11 bits + sign |
| Conversion Time | 2.5 ms |
| Resolution | 10.25 µA (current); 5.12 mV (voltage) |
| Measurement Error (25°C) | 0.45% FS (±10V); 0.52% FS (0-20mA/4-20mA) |
| Measurement Error (0-60°C) | 0.75% FS (±10V); 0.98% FS (0-20mA/4-20mA) |
| Isolation (Channel to Channel) | 1500 Vrms |
| Isolation (Channel to Bus) | 1500 Vrms |
| Isolation (Channel to Ground) | 500 V |
| Load Impedance (Current) | < 600 Ω (0-20 mA, 4-20 mA) |
| Load Impedance (Voltage) | > 1000 Ω (±10 V) |
| Max Load Inductance | 300 µH |
| Max Load Capacitance | 0.1 µF |
| Output Voltage Limit | ≤ 30 V |
| Current Consumption | 900 mA @ 5V DC |
| Power Supply | 24V DC |
| Power Consumption | 3 W |
| Electrical Connection | Screw terminal block |
| Protection | Overload, short-circuit |
| Dimensions (W x H x D) | 125 x 100 x 40 mm |
| Net Weight | 0.35 kg (0.77 lb) |
| IP Degree of Protection | IP20 |
| Pollution Degree | 2 |
| Operating Temperature | 0°C to +60°C |
| Storage Temperature | -25°C to +70°C |
| Relative Humidity | 10-95% (operation); 5-95% (storage), non-condensing |
| Operating Altitude | 0-2000 m |
| Certifications | CE, UL 508, CSA, IEC 61131-2, GL, ABS, RINA, DNV |
| Country of Origin | France |
Installation Notes
Mount in Modicon Premium or TSX Micro PLC rack. Connect field wiring via screw terminal block. Use shielded cable for analog signals and connect shields to the designated shield terminals. Observe load impedance limits: <600 Ω for current output, >1000 Ω for voltage output. Maintain IP20 enclosure and pollution degree 2 environment. Ensure operating temperature remains between 0°C and 60°C.
Engineering Advantages
Selectable current or voltage output on each channel provides application flexibility. 1500 Vrms channel-to-channel isolation protects against ground loops and noise. High 11-bit + sign resolution ensures precise analog control. Overload and short-circuit protection safeguard the module and connected equipment. Compact 0.35 kg design saves panel space. Marine certifications (GL, ABS, RINA, DNV) enable use in shipboard and offshore applications.
FAQs
Q1: What output types are available?
A1: Current (0-20 mA, 4-20 mA) and voltage (±10 V).
Q2: What is the isolation rating?
A2: 1500 Vrms between channels and bus, 500 V between channels and ground.
Q3: What is the power consumption?
A3: 3 W at 24V DC supply, with 900 mA current consumption at 5V DC.
Ƙarin ƙayyadaddun bayanai
Sikeli (V/f)
Vector
mai amfani da wutar AC
Jagorar Sayi
- Tabbatar da ainihin samfurin, lambar ɓangare, da ƙayyadaddun bayanai kafin yin oda.
- Tabbatar da jituwa da injin ko tsarin kula da kake amfani da su a yanzu.
- Tuntuɓe mu ta sale@etowonauto.com ko +8617859788089 don taimakon fasaha.
- Duba zaɓuɓɓukan isarwa, lokacin jagora, da buƙatun jigilar kaya.
- Bi umarnin masana’anta da mafi kyawun hanyoyin aiki yayin girkawa.
Isarwa da Mayar da Kaya
Kayayyakin da ke cikin sito yawanci ana tura su a cikin wannan ranar aikin. Ga kayayyakin da ba sa cikin sito a yanzu, lokacin tura su na iya bambanta bisa ga samuwa. Ana ba da jigilar kaya zuwa ƙasashen waje, kuma ana ƙididdige kuɗin jigila bisa wurin da ake aikawa, nauyi, da kamfanin sufuri da aka zaɓa.
Ana karɓar mayar da kaya cikin kwanaki 30 bayan karɓa, muddin kayan ba a yi amfani da su ba kuma suna cikin yanayin da suka fito daga masana’anta. Kuɗin jigilar mayar da kaya nauyi ne a kan abokin ciniki. Da fatan za a tuntube mu kafin ku mayar da duk wani kaya domin samun izinin mayarwa.
Don ƙarin bayani, don Allah ku duba Manufar Jigila & Mayar da Kaya.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Isarwa cikin gaggawa
Sassan kayan otomeshan na masana’antu na ainihi suna nan a shirye don aikawa cikin gaggawa a ko’ina cikin duniya.
-
Mayar da kaya cikin sauƙi
Tallafin mayar da kaya na kwanaki 30 tare da garantin watanni 12 don tabbatacciyar kariya bayan saye.
-
Taimako a kowane lokaci (24/7)
Tallafin ƙwararru mai saurin amsawa don taimakawa kiyaye ayyuka cikin kwanciyar hankali da inganci.
-
Na Gaskiya & Asali
Kashi 100% na asali ne, ana samar da su kai tsaye daga amintattun masana’antun kayan sarrafa masana’antu.
Jagorar Fasaha da Siyarwa
-
What Makes Emerson DeltaV M-Series Ideal for Oil & Gas DCS Control?
Emerson's DeltaV M-Series controller delivers reliable regulatory control for oil and gas assets through MQ and MX va...
-
What Makes Siemens PCS 7 AS410 Ideal for Chemical DCS?
Siemens PCS 7 with the AS410 automation station delivers high availability for continuous chemical manufacturing. Thi...
-
What Causes Most ABB AC800M Migration Failures?
ABB AC800M controllers have run for 12 to 18 years in many plants, and spare part lead times now reach 16 weeks. This...
-
How to Migrate Honeywell TDC3000 to Experion PKS?
This guide explains how process plants can migrate aging Honeywell TDC3000 DCS systems to Experion PKS C300 through p...
-
What Makes PLC and DCS Migration Projects Succeed?
Multi-vendor control system migration demands disciplined project management, early interface testing, and structured...
-
How Does GE OPC UA Server Connect Mixed PLC and DCS Systems?
GE OPC UA server helps industrial plants unify fragmented PLC and DCS data through a vendor-neutral standard, coverin...