Canza gidanka da sabbin hanyoyin na’urorin lantarki masu yawa, daga hasken wuta mai hankali zuwa inganta ayyukanka da Bently Nevada 3500 Monitoring System, wanda ke ba da sa ido a ainihin lokaci kan girgiza da yanayin na’urorin injina don hana gazawa da ƙara lokacin aiki, da na’urorin da ake sarrafa su da murya duk an ƙera su ne don sauƙaƙa rayuwa, ƙara tsaro, da ƙarfafa haɗin kai.
SKU:ATV71HD30N4
Schneider Electric ATV71HD30N4 Variable Speed Drive 40 hp Brand
Manufacturer: Schneider
Product No.: ATV71HD30N4
Product Type: Variable Speed Drive
Product Origin: FR
Payment:T/T, Western Union
Weight: 37000g
Shipping port: Xiamen
Warranty: 12 months
Raba
- Isarwa Cikin Gaggawa
- Tallafi na awa 24 a rana, kwana 7 a mako
- Tabbacin Inganci
Bayani
Schneider Electric ATV71HD30N4 Altivar 71 Variable Speed Drive
The Schneider Electric ATV71HD30N4, also cataloged as the ATV71HD30N4 Variable Speed Drive, operates as a three-phase drive delivering 30 kW (40 hp) motor power from a 380-480 VAC input with integrated EMC filter and graphic terminal within Altivar 71 platforms.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | ATV71HD30N4 |
| Brand | Schneider Electric |
| Product Type | Variable Speed Drive |
| Product Line | Altivar 71 |
| Weight | 37 kg net (81.6 lb) |
| Dimensions (W x H x D) | 240 mm x 550 mm x 266 mm |
| Phase | 3-phase |
| Input Voltage | 380-480 VAC, -15% to +10%; limits 323-528 V |
| Input Frequency | 50/60 Hz, -5% to +5%; limits 47.5-63 Hz |
| Motor Power | 30 kW / 40 hp |
| Line Current | 56 A at 480 V; 66 A at 380 V |
| Nominal Output Current | 52 A at 460 V; 66 A at 380 V (4 kHz) |
| Maximum Transient Current | 109 A for 2 s; 99 A for 60 s |
| Output Frequency | 0.1 to 599 Hz |
| Nominal Switching Frequency | 4 kHz; adjustable 1-16 kHz |
| Apparent Power | 43.4 kVA at 380 V |
| Prospective Line Isc | 22 kA |
| Operating Temp | -10 deg C to 50 deg C without derating |
| Storage Temp | -25 deg C to 70 deg C |
| Relative Humidity | 5-95% without condensation |
| IP Degree of Protection | IP20 |
| EMC Filter | Integrated |
| Graphic Terminal | Included |
| Max Motor Cable Length | 100 m shielded; 200 m unshielded |
| Communication Protocol | Modbus (2-wire RS 485), CANopen |
| Certifications | CE, UL, CSA, C-tick, GOST, NOM 117 |
| EAN | 3389118069510 |
Frequently Asked Questions
Q: What is the net weight of the ATV71HD30N4?
A: 37 kg (81.6 lb) net. The shipping package weighs approximately 12.0 kg.
Q: What motor cable length is permitted with this drive?
A: 100 m with shielded cable and 200 m with unshielded cable.
Q: What is the STO response time and safety rating of the PWR input?
A: Response time is 100 ms or less. The PWR safety input meets ISO 13849-1 level d.
Field Installation Guidelines
Mount the drive vertically within +/-10 degrees on a panel with the heat sink airflow path unobstructed. Verify three-phase input is within 323-528 V and 47.5-63 Hz before energizing. Confirm prospective short-circuit current at the installation point does not exceed 22 kA. Route motor cables within 100 m shielded or 200 m unshielded limits. Separate power and control wiring; control terminals accept 2.5 mm2 (AWG 14) and power terminals accept 50 mm2 (AWG 1/0). Tighten power terminals to 12 N.m and control terminals to 0.6 N.m. Ground the drive per site standards and verify dielectric isolation before commissioning. Derate output current by 1% per 100 m above 1000 m altitude. Verify the integrated EMC filter configuration matches the installation environment category before connecting the motor.
Ƙarin ƙayyadaddun bayanai
- Launin toka
- mai aiki da wutar DC
- Ƙarami
Sikeli (V/f)
Vector
mai amfani da wutar AC
Jagorar Sayi
- Tabbatar da ainihin samfurin, lambar ɓangare, da ƙayyadaddun bayanai kafin yin oda.
- Tabbatar da jituwa da injin ko tsarin kula da kake amfani da su a yanzu.
- Tuntuɓe mu ta sale@etowonauto.com ko +8617859788089 don taimakon fasaha.
- Duba zaɓuɓɓukan isarwa, lokacin jagora, da buƙatun jigilar kaya.
- Bi umarnin masana’anta da mafi kyawun hanyoyin aiki yayin girkawa.
Isarwa da Mayar da Kaya
Kayayyakin da ke cikin sito yawanci ana tura su a cikin wannan ranar aikin. Ga kayayyakin da ba sa cikin sito a yanzu, lokacin tura su na iya bambanta bisa ga samuwa. Ana ba da jigilar kaya zuwa ƙasashen waje, kuma ana ƙididdige kuɗin jigila bisa wurin da ake aikawa, nauyi, da kamfanin sufuri da aka zaɓa.
Ana karɓar mayar da kaya cikin kwanaki 30 bayan karɓa, muddin kayan ba a yi amfani da su ba kuma suna cikin yanayin da suka fito daga masana’anta. Kuɗin jigilar mayar da kaya nauyi ne a kan abokin ciniki. Da fatan za a tuntube mu kafin ku mayar da duk wani kaya domin samun izinin mayarwa.
Don ƙarin bayani, don Allah ku duba Manufar Jigila & Mayar da Kaya.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Isarwa cikin gaggawa
Sassan kayan otomeshan na masana’antu na ainihi suna nan a shirye don aikawa cikin gaggawa a ko’ina cikin duniya.
-
Mayar da kaya cikin sauƙi
Tallafin mayar da kaya na kwanaki 30 tare da garantin watanni 12 don tabbatacciyar kariya bayan saye.
-
Taimako a kowane lokaci (24/7)
Tallafin ƙwararru mai saurin amsawa don taimakawa kiyaye ayyuka cikin kwanciyar hankali da inganci.
-
Na Gaskiya & Asali
Kashi 100% na asali ne, ana samar da su kai tsaye daga amintattun masana’antun kayan sarrafa masana’antu.
Jagorar Fasaha da Siyarwa
-
Why Does PCS7 OS Server Redundancy Fail Over?
This guide explains how to diagnose and repair Siemens PCS7 OS server redundancy failover anomalies using quantified ...
-
How Do You Recover a Bricked Allen-Bradley PLC?
This article explains how industrial automation teams classify bricked Allen-Bradley Logix controllers, validate firm...
-
How Can You Prevent Historian Data Loss During Experion PKS Migration?
This article presents a measurable playbook for protecting Honeywell Experion historian data during server and H...
-
How Do MTL Barriers and DCS IO Cards Affect Loop Voltage?
Intrinsic safety circuits protect hazardous process areas, yet loop impedance budgeting often receives far less atten...
-
How Can You Tune GE RX3i and RX7i Ethernet for Heavy Industry?
Intermittent Ethernet timeouts on GE RX3i and RX7i controllers are among the hardest faults in heavy process plants, ...
-
Why Does FCS Redundancy Not Protect Your HIS Configuration?
This article examines the operational risks of Yokogawa CENTUM VP HIS lockups and explains why FCS controller re...