Canza gidanka da sabbin hanyoyin na’urorin lantarki masu yawa, daga hasken wuta mai hankali zuwa inganta ayyukanka da Bently Nevada 3500 Monitoring System, wanda ke ba da sa ido a ainihin lokaci kan girgiza da yanayin na’urorin injina don hana gazawa da ƙara lokacin aiki, da na’urorin da ake sarrafa su da murya duk an ƙera su ne don sauƙaƙa rayuwa, ƙara tsaro, da ƙarfafa haɗin kai.
SKU:MTL5021
MTL5021 Hazardous Area Driver - MTL Instruments
Manufacturer: MTL
Product No.: MTL5021
Product Type: Control Driver
Product Origin: USA
Payment:T/T, Western Union
Weight: 110g
Shipping port: Xiamen
Warranty: 12 months
Raba
- Isarwa Cikin Gaggawa
- Tallafi na awa 24 a rana, kwana 7 a mako
- Tabbacin Inganci
Bayani
MTL5021 Hazardous Area Control Driver
The MTL5021 from MTL Instruments provides safe control of hazardous area devices from safe area switches. This single-channel interface drives intrinsically safe low-power loads and non-energy-storing apparatus like LEDs. Its flexible input/output isolation allows control switch connection on either side of the 24V DC supply circuit.
Key Technical Specifications
- Brand: MTL Instruments
- Model: MTL5021
- Product Type: Hazardous Area Control Driver
- Channels: One channel
- Output Current: 45mA maximum
- Input Voltage: 20 to 35V DC
- Status Indicator: Yellow LED for operational status
Hazardous Area Certification
- Load Location: Zone 0, IIC, T4-T6 hazardous area
- Division Rating: Division 1, Group A hazardous location
- The MTL5021 maintains intrinsic safety for connected loads
- It enables safe control of devices in explosive atmospheres
Output Performance
- Minimum Output Voltage: 12.85V at 45mA
- Maximum Output Voltage: 24V from 170Ω
- Current Limit: 45mA maximum for safety
- Output Terminals: Terminal 1 (Output –ve), Terminal 2 (Output +ve)
- Suitable for intrinsically safe low-power loads and LED indicators
Power Requirements
- Input Voltage: 20 to 35V DC operating range
- Current Consumption: 90mA at 24V with 45mA output
- Power Dissipation: 1.4W at 24V typical
- Maximum Dissipation: 1.8W at 35V
- Supply Terminals: Terminal 11 (Supply –ve), Terminal 12 (Supply +ve)
Terminal Configuration
- Output: Terminal 1 (Output –ve), Terminal 2 (Output +ve)
- Earth Leakage: Terminal 3 for detection capability
- Power Supply: Terminal 11 (Supply –ve), Terminal 12 (Supply +ve)
- Flexible wiring allows control switch on either supply side
- Clear terminal identification simplifies installation
Safety Parameters
- Safety Voltage: 25V maximum
- Internal Resistance: 170Ω
- Safety Current: 147mA maximum
- Isolation Voltage: Um = 250V rms or DC
- Comprehensive protection for hazardous area operation
Frequently Asked Questions
-
What type of loads can the MTL5021 drive?
It drives intrinsically safe low-power loads and non-energy-storing apparatus like LEDs. -
What is the maximum output current?
The output is current limited to 45mA for safety compliance. -
How flexible is the control switch wiring?
The switch can be connected into either side of the 24V DC supply circuit. -
Is this suitable for Zone 0 applications?
Yes, it carries full certification for Zone 0, IIC, T4-T6 hazardous areas.
Ƙarin ƙayyadaddun bayanai
Sikeli (V/f)
Vector
mai amfani da wutar AC
Jagorar Sayi
- Tabbatar da ainihin samfurin, lambar ɓangare, da ƙayyadaddun bayanai kafin yin oda.
- Tabbatar da jituwa da injin ko tsarin kula da kake amfani da su a yanzu.
- Tuntuɓe mu ta sale@etowonauto.com ko +8617859788089 don taimakon fasaha.
- Duba zaɓuɓɓukan isarwa, lokacin jagora, da buƙatun jigilar kaya.
- Bi umarnin masana’anta da mafi kyawun hanyoyin aiki yayin girkawa.
Isarwa da Mayar da Kaya
Kayayyakin da ke cikin sito yawanci ana tura su a cikin wannan ranar aikin. Ga kayayyakin da ba sa cikin sito a yanzu, lokacin tura su na iya bambanta bisa ga samuwa. Ana ba da jigilar kaya zuwa ƙasashen waje, kuma ana ƙididdige kuɗin jigila bisa wurin da ake aikawa, nauyi, da kamfanin sufuri da aka zaɓa.
Ana karɓar mayar da kaya cikin kwanaki 30 bayan karɓa, muddin kayan ba a yi amfani da su ba kuma suna cikin yanayin da suka fito daga masana’anta. Kuɗin jigilar mayar da kaya nauyi ne a kan abokin ciniki. Da fatan za a tuntube mu kafin ku mayar da duk wani kaya domin samun izinin mayarwa.
Don ƙarin bayani, don Allah ku duba Manufar Jigila & Mayar da Kaya.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Isarwa cikin gaggawa
Sassan kayan otomeshan na masana’antu na ainihi suna nan a shirye don aikawa cikin gaggawa a ko’ina cikin duniya.
-
Mayar da kaya cikin sauƙi
Tallafin mayar da kaya na kwanaki 30 tare da garantin watanni 12 don tabbatacciyar kariya bayan saye.
-
Taimako a kowane lokaci (24/7)
Tallafin ƙwararru mai saurin amsawa don taimakawa kiyaye ayyuka cikin kwanciyar hankali da inganci.
-
Na Gaskiya & Asali
Kashi 100% na asali ne, ana samar da su kai tsaye daga amintattun masana’antun kayan sarrafa masana’antu.
Jagorar Fasaha da Siyarwa
-
What Makes S7-400H Redundant PLC Ideal for Power Auxiliary Control?
Siemens S7-400H redundant PLC delivers proven hot standby performance for power auxiliary control. This guide covers ...
-
What Makes Honeywell HC900 Ideal for Fine Chemical Batch Control?
This technical guide examines the Honeywell ControlEdge HC900 hybrid PLC/DCS platform for fine chemical batch manufac...
-
How Does the Bently Nevada 1900 Protect Industrial Fans?
This article reviews the Bently Nevada 1900 vibration monitor for industrial fan assets, covering hardware specificat...
-
How Does ABB Ability 800xA Improve Power Plant Automation?
ABB Ability 800xA remains a leading distributed control system for heavy continuous process plants in power and chemi...
-
How Does Emerson Ovation DCS Improve Turbine-Boiler Control?
Emerson Ovation DCS delivers fast scan cycles, redundant controllers, and advanced feed-forward logic for turbin...
-
How Do You Migrate Siemens S7-300/400 to S7-1500?
This guide explains how to migrate Siemens S7-300/400 PLCs to the S7-1500 platform using TIA Portal, covering perform...
