Canza gidanka da sabbin hanyoyin na’urorin lantarki masu yawa, daga hasken wuta mai hankali zuwa inganta ayyukanka da Bently Nevada 3500 Monitoring System, wanda ke ba da sa ido a ainihin lokaci kan girgiza da yanayin na’urorin injina don hana gazawa da ƙara lokacin aiki, da na’urorin da ake sarrafa su da murya duk an ƙera su ne don sauƙaƙa rayuwa, ƙara tsaro, da ƙarfafa haɗin kai.
SKU:MTL5053
MTL Instruments MTL5053 H1 Fieldbus Barrier
Manufacturer: MTL
Product No.: MTL5053
Product Type: Control Driver
Product Origin: USA
Payment:T/T, Western Union
Weight: 110g
Shipping port: Xiamen
Warranty: 12 months
Raba
- Isarwa Cikin Gaggawa
- Tallafi na awa 24 a rana, kwana 7 a mako
- Tabbacin Inganci
Bayani
MTL5053 Fieldbus Hazardous Area Isolator
The MTL5053 from MTL Instruments extends 31.25kbit/s H1 fieldbus networks into hazardous areas. This specialized interface provides both power and communication to fieldbus devices through signal conductors. Featuring an internal terminator and Fieldbus Foundation compliance, it offers a complete solution for industrial network expansion.
Key Technical Specifications
- Brand: MTL Instruments
- Model: MTL5053
- Product Type: Fieldbus Hazardous Area Isolator
- Data Rate: 31.25kbit/s (H1)
- Fieldbus Power: 80mA maximum current
- Supply Voltage: 20 to 35V DC
- Compliance: Fieldbus Foundation Type 133
Hazardous Area Certification
- Device Location: Zone 0, IIC, T4-T6 hazardous area
- The MTL5053 maintains intrinsic safety for fieldbus networks
- It enables safe operation of fieldbus devices in explosive atmospheres
- Comprehensive certification for hazardous area installation
Fieldbus Power Supply
- Output Voltage: 18.4V ±2%
- DC Impedance: 105Ω ±3%
- Maximum Current: 80mA for fieldbus devices
- Cable Length: Determined by intrinsic safety requirements
- Provides power through fieldbus signal conductors
Digital Signal Transmission
- Data Rate: 31.25kbit/s H1 fieldbus
- Compliance: Meets Fieldbus Foundation standards
- Internal Terminator: Switch-selectable on module top
- Ideal for installations with short safe-area bus lengths
- Maintains signal integrity in hazardous environments
Power Requirements
- Supply Voltage: 20 to 35V DC operating range
- Current Consumption: 135mA typical at 24V with 80mA load
- Power Dissipation: 2.3W typical at 24V
- Maximum Dissipation: 2.6W at 35V
- Status Indicator: Green LED for power monitoring
Installation Requirements
- Mounting: Horizontal DIN-rail on vertical surface recommended
- Spacing: 10mm between adjacent units
- Spacers: MTL MS010 spacers available for proper installation
- Temperature: Maximum 45°C for non-optimum orientation
- Adequate heat dissipation ensures reliable operation
Safety & Isolation
- Isolation: 250V AC between all circuits
- Safety Voltage: 22V maximum for terminals 1-2
- Internal Resistance: 102Ω
- Safety Current: 216mA maximum
- Maximum Voltage: Um = 250V rms or DC
Frequently Asked Questions
-
What fieldbus standard does the MTL5053 support?
It supports 31.25kbit/s H1 fieldbus and complies with Fieldbus Foundation Type 133 requirements. -
How much power can it provide to fieldbus devices?
It delivers up to 80mA at 18.4V for fieldbus device power. -
Does it include termination capability?
Yes, an internal terminator can be enabled via a switch on the module top. -
What are the mounting requirements?
For optimal performance, mount on horizontal DIN-rail with 10mm spacing between units.
Ƙarin ƙayyadaddun bayanai
Sikeli (V/f)
Vector
mai amfani da wutar AC
Jagorar Sayi
- Tabbatar da ainihin samfurin, lambar ɓangare, da ƙayyadaddun bayanai kafin yin oda.
- Tabbatar da jituwa da injin ko tsarin kula da kake amfani da su a yanzu.
- Tuntuɓe mu ta sale@etowonauto.com ko +8617859788089 don taimakon fasaha.
- Duba zaɓuɓɓukan isarwa, lokacin jagora, da buƙatun jigilar kaya.
- Bi umarnin masana’anta da mafi kyawun hanyoyin aiki yayin girkawa.
Isarwa da Mayar da Kaya
Kayayyakin da ke cikin sito yawanci ana tura su a cikin wannan ranar aikin. Ga kayayyakin da ba sa cikin sito a yanzu, lokacin tura su na iya bambanta bisa ga samuwa. Ana ba da jigilar kaya zuwa ƙasashen waje, kuma ana ƙididdige kuɗin jigila bisa wurin da ake aikawa, nauyi, da kamfanin sufuri da aka zaɓa.
Ana karɓar mayar da kaya cikin kwanaki 30 bayan karɓa, muddin kayan ba a yi amfani da su ba kuma suna cikin yanayin da suka fito daga masana’anta. Kuɗin jigilar mayar da kaya nauyi ne a kan abokin ciniki. Da fatan za a tuntube mu kafin ku mayar da duk wani kaya domin samun izinin mayarwa.
Don ƙarin bayani, don Allah ku duba Manufar Jigila & Mayar da Kaya.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Isarwa cikin gaggawa
Sassan kayan otomeshan na masana’antu na ainihi suna nan a shirye don aikawa cikin gaggawa a ko’ina cikin duniya.
-
Mayar da kaya cikin sauƙi
Tallafin mayar da kaya na kwanaki 30 tare da garantin watanni 12 don tabbatacciyar kariya bayan saye.
-
Taimako a kowane lokaci (24/7)
Tallafin ƙwararru mai saurin amsawa don taimakawa kiyaye ayyuka cikin kwanciyar hankali da inganci.
-
Na Gaskiya & Asali
Kashi 100% na asali ne, ana samar da su kai tsaye daga amintattun masana’antun kayan sarrafa masana’antu.
Jagorar Fasaha da Siyarwa
-
Yaya Dogaro da Sassan Tsarin Kula da Kai na Ku Ne Kan Magudin Kaya?
Wannan labarin yana gabatar da wata hanya mai dogaro da bayanai don tabbatar da sahihancin na’urorin Emerson DCS ga a...
-
Me Ya Sa Ya Kamata a Hada TSI da PLC don Tashoshin Na’urar Dannewa Iskar Gas?
Wannan makalar fasaha tana nazarin haɗa tsarin Bently Nevada 3500 TSI da dandamalin GE Fanuc PLC don wayayyen tsarin ...
-
Me Yasa Juyawa Cikin 50ms Ya Zama Muhimmi Ga Masanantu Masu Hankali na Industry 4.0?
Wannan makalar tana nazarin cikakken tsarin maimaitawar haɗin ABB DCS ga masana’antar harhade magunguna ƙarƙashin ka’...
-
Menene Manyan Musabbaban Kurakuran Sadarwar TSI Masu Yawan Yanke-Yanke?
Wannan labarin yana gabatar da hanyar warware matsaloli ta hanyar ƙididdiga don gazawar sadarwa tsakanin GE Fanuc PLC...
-
Yadda Ake Kariya da Tsare Emerson DeltaV DCS a Lokacin Industry 4.0
Wannan labarin yana gabatar da ingantattun dabarun ƙarfafa tsaron Emerson DeltaV DCS da suka yi daidai da ka’idojin I...
-
Shin Masaninku na Harkar Karafa na Asarar Miliyoyi Saboda Asarar Makamashi da Ba a Gani?
Shuke-shuken ƙarafa suna ɓata babbar makamashi saboda tsarin PLC da DCS da aka rarraba daban-daban waɗanda ba za su i...