Canza gidanka da sabbin hanyoyin na’urorin lantarki masu yawa, daga hasken wuta mai hankali zuwa inganta ayyukanka da Bently Nevada 3500 Monitoring System, wanda ke ba da sa ido a ainihin lokaci kan girgiza da yanayin na’urorin injina don hana gazawa da ƙara lokacin aiki, da na’urorin da ake sarrafa su da murya duk an ƙera su ne don sauƙaƙa rayuwa, ƙara tsaro, da ƙarfafa haɗin kai.
SKU:MAI51
GE MAI51 369B1841G5007 Analog Input Module 16 Channel
Manufacturer: General Electric
Product No.: MAI51
Product Type: Analog Input Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 500g
Shipping port: Xiamen
Warranty: 12 months
Raba
- Isarwa Cikin Gaggawa
- Tallafi na awa 24 a rana, kwana 7 a mako
- Tabbacin Inganci
Bayani
GE MAI51 369B1841G5007 Analog Input Module
The GE MAI51 (369B1841G5007) is a 16-channel analog input module supporting RTD (Pt10, Pt100, Cu100, Cu50) and thermocouple types (E, J, K, N, R, S, T, B). Featuring dual 24 V DC (±10%) redundant power inputs, this module delivers 16-bit resolution with 0.2% measurement accuracy. Weighing approximately 0.5 kg (1.1 lbs), it operates from 0°C to 60°C with CE certification.
Technical Specifications
| Parameter | Value |
|---|---|
| Manufacturer | GE |
| Model | MAI51 (369B1841G5007) |
| Product Type | TC/RTD Analog Input Module |
| Channels | 16 (8 channels per ADC group) |
| Power Supply | Dual 24 V DC ±10% (1:1 Redundant) |
| Power Consumption | < 2 W (Typical 1.8 W) |
| Signal Types | RTD: Pt10, Pt100, Cu100, Cu50; TC: E, J, K, N, R, S, T, B |
| ADC Resolution | 16-bit |
| Measurement Accuracy | 0.2% maximum |
| Over-range Alarm | ±10% (software configurable) |
| CMRR | > 120 dB |
| DMRR | > 60 dB |
| Isolation (Channel-Channel) | 250 V AC |
| Isolation (Channel-Ground) | 500 V AC |
| Isolation (Channel-System) | 1500 V AC |
| Operating Temperature | 0°C to 60°C (32°F to 140°F) |
| Humidity | 10-90% non-condensing |
| Dimensions (H x W x D) | 209 x 129.5 x 51 mm (8.2 x 5.1 x 2.0 in) |
| Weight | Approx. 0.5 kg (1.1 lbs) |
| Mounting | Screw Mounting |
| Communication | Redundant High-Speed Smart Serial Bus (1 Mbps) |
| Connector | Single-row Euro-style, Removable (2.5 mm²) |
| LED Indicators | Run, Communication, Fault Alarm |
| Certification | CE (with system) |
Supported Signal Types
| Sensor Type | Supported Models |
|---|---|
| RTD | Pt10, Pt100, Cu100, Cu50 (2-wire or 3-wire) |
| Thermocouple | E, J, K, N, R, S, T, B |
Installation & Field Application Guide
- Mount the module using screw mounting. Ensure proper grounding for noise immunity.
- Connect dual 24 V DC power supplies (21.6-26.4 V DC range) for 1:1 redundancy.
- Use shielded twisted-pair wiring for RTD and TC signals. Ground shield at the module end only.
- Configure sensor type and range using the system software. Over-range alarm threshold is ±10%.
Why Choose the MAI51 Module
- 16 channels support both RTD and thermocouple inputs in a single module.
- Dual redundant 24 V DC power inputs for high availability applications.
- High isolation (1500 V AC channel-system) ensures reliable operation.
- 0.2% accuracy with 16-bit resolution for precise temperature measurement.
Field Engineer FAQs
Q1: What is the difference between 2-wire and 3-wire RTD connection?
A1: 3-wire connection compensates for lead wire resistance, providing more accurate measurements. 2-wire is suitable for short cable runs where lead resistance is negligible.
Q2: Does the module support cold junction compensation for thermocouples?
A2: Yes, the module provides built-in cold junction compensation when using the terminal block temperature sensor.
Q3: What is the maximum cable length for TC/RTD inputs?
A3: Recommended maximum cable length is 200 meters for shielded twisted-pair wiring. For longer runs, use signal conditioning.
Inquiries: sale@etowonauto.com
Ƙarin ƙayyadaddun bayanai
Sikeli (V/f)
Vector
mai amfani da wutar AC
Jagorar Sayi
- Tabbatar da ainihin samfurin, lambar ɓangare, da ƙayyadaddun bayanai kafin yin oda.
- Tabbatar da jituwa da injin ko tsarin kula da kake amfani da su a yanzu.
- Tuntuɓe mu ta sale@etowonauto.com ko +8617859788089 don taimakon fasaha.
- Duba zaɓuɓɓukan isarwa, lokacin jagora, da buƙatun jigilar kaya.
- Bi umarnin masana’anta da mafi kyawun hanyoyin aiki yayin girkawa.
Isarwa da Mayar da Kaya
Kayayyakin da ke cikin sito yawanci ana tura su a cikin wannan ranar aikin. Ga kayayyakin da ba sa cikin sito a yanzu, lokacin tura su na iya bambanta bisa ga samuwa. Ana ba da jigilar kaya zuwa ƙasashen waje, kuma ana ƙididdige kuɗin jigila bisa wurin da ake aikawa, nauyi, da kamfanin sufuri da aka zaɓa.
Ana karɓar mayar da kaya cikin kwanaki 30 bayan karɓa, muddin kayan ba a yi amfani da su ba kuma suna cikin yanayin da suka fito daga masana’anta. Kuɗin jigilar mayar da kaya nauyi ne a kan abokin ciniki. Da fatan za a tuntube mu kafin ku mayar da duk wani kaya domin samun izinin mayarwa.
Don ƙarin bayani, don Allah ku duba Manufar Jigila & Mayar da Kaya.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Isarwa cikin gaggawa
Sassan kayan otomeshan na masana’antu na ainihi suna nan a shirye don aikawa cikin gaggawa a ko’ina cikin duniya.
-
Mayar da kaya cikin sauƙi
Tallafin mayar da kaya na kwanaki 30 tare da garantin watanni 12 don tabbatacciyar kariya bayan saye.
-
Taimako a kowane lokaci (24/7)
Tallafin ƙwararru mai saurin amsawa don taimakawa kiyaye ayyuka cikin kwanciyar hankali da inganci.
-
Na Gaskiya & Asali
Kashi 100% na asali ne, ana samar da su kai tsaye daga amintattun masana’antun kayan sarrafa masana’antu.
Jagorar Fasaha da Siyarwa
-
Why Do ABB AC800M Redundancy Mismatch Faults Keep Returning?
ABB AC800M redundancy mismatch faults account for 42.7 percent of controller alarms in 800xA systems. Most stem ...
-
How Does Honeywell C300 Improve on C200 DCS Controllers?
Honeywell C300 controllers deliver major gains over C200 in memory, scan speed, redundancy switching, and reliability...
-
How Does the 1756-RM2 Redundancy Module Work?
This article explains how to install, configure and tune the Allen-Bradley 1756-RM2 redundancy module for Contro...
-
How Do You Migrate DeltaV Classic DCS Without Plant Shutdown?
This article explains why Emerson DeltaV Classic systems reach technical limits after 15 to 20 years and how plants c...
-
What Makes Bently Nevada System 1 Essential for Predictive Maintenance?
Bently Nevada System 1 is a dedicated vibration analytics platform that pairs with 3500 TSI racks to deliver hig...
-
Is ABB MOD300 DCS Migration Still Worth the Investment?
ABB Advant MOD300 systems still run in many refineries and power plants, yet aging capacitors, scarce spares and hidd...