Canza gidanka da sabbin hanyoyin na’urorin lantarki masu yawa, daga hasken wuta mai hankali zuwa inganta ayyukanka da Bently Nevada 3500 Monitoring System, wanda ke ba da sa ido a ainihin lokaci kan girgiza da yanayin na’urorin injina don hana gazawa da ƙara lokacin aiki, da na’urorin da ake sarrafa su da murya duk an ƙera su ne don sauƙaƙa rayuwa, ƙara tsaro, da ƙarfafa haɗin kai.
SKU:IC693MDL250
GE Fanuc IC693MDL250 16-Point Isolated Module 1500V RMS
Manufacturer: General Electric
Product No.: IC693MDL250
Product Type: Input Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 400g
Shipping port: Xiamen
Warranty: 12 months
Raba
- Isarwa Cikin Gaggawa
- Tallafi na awa 24 a rana, kwana 7 a mako
- Tabbacin Inganci
Bayani
GE Fanuc IC693MDL250 Isolated Input Module Series 90-30
GE Fanuc IC693MDL250 is a 16-point isolated AC input module for the Series 90-30 PLC platform. Operates on 120V AC nominal with 0-132V AC range. Features 1500V RMS isolation between field and logic side with built-in RC snubber for noise protection. Weight: 0.4 kg (0.88 lbs).
Technical Specifications
| Parameter | Specification |
| Manufacturer | GE Fanuc / GE Intelligent Platforms |
| Model | IC693MDL250 |
| Series | Series 90-30 |
| Product Type | Isolated Input Module |
| Number of Inputs | 16 isolated AC inputs |
| Voltage Rating | 120V AC nominal |
| Voltage Range | 0 to 132V AC |
| Frequency | 47 to 63 Hz |
| Input Current at 120V AC | 14.5 mA |
| On-State Voltage | 70 to 132V AC |
| On-State Current | 5 mA minimum |
| Off-State Voltage | 0 to 20V AC |
| Off-State Current | 2.5 mA maximum |
| Isolation Voltage | 1500V RMS between field and logic side |
| RC Snubber | Built-in for noise protection |
| LED Indicators | 16 channel status LEDs plus terminal block lock indicator |
| Operating Temperature | 0°C to +60°C |
| Storage Temperature | -40°C to +85°C |
| Weight | 0.4 kg (0.88 lbs) |
Key Features
- 16 isolated AC input points for Series 90-30 systems
- 1500V RMS isolation between field and logic side
- Built-in RC snubber for noise protection
- 16 channel status LEDs plus terminal block lock indicator
- Wide operating temperature range 0°C to +60°C
- High isolation for reliable performance
Installation Guidelines (Field Engineer Notes)
Chassis Installation: Insert module into any available slot in Series 90-30 rack. Power off before insertion. Secure with captive screws to 0.6 N·m.
Wiring: Connect 120V AC field devices to input terminals. Use 14-22 AWG wire. Torque terminal screws to 0.56 N·m.
Isolation Check: The module provides 1500V RMS isolation. No additional isolation required for standard applications.
Voltage Verification: Verify 70-132V AC between input and common for On-State. Off-State voltage must be below 20V AC.
FAQs
Q1. What is the minimum On-State current required?
A1. The minimum On-State current is 5 mA. If field device current drops below this, the module may not detect the input.
Q2. Does this module provide isolation between inputs?
A2. Yes. The module provides isolation between field and logic side. Inputs are isolated from each other.
Q3. What is the off-state voltage maximum?
A3. Off-State voltage must be below 20V AC. If voltage exceeds 20V AC when the input should be OFF, the module may read a false ON condition.
Ƙarin ƙayyadaddun bayanai
Sikeli (V/f)
Vector
mai amfani da wutar AC
Jagorar Sayi
- Tabbatar da ainihin samfurin, lambar ɓangare, da ƙayyadaddun bayanai kafin yin oda.
- Tabbatar da jituwa da injin ko tsarin kula da kake amfani da su a yanzu.
- Tuntuɓe mu ta sale@etowonauto.com ko +8617859788089 don taimakon fasaha.
- Duba zaɓuɓɓukan isarwa, lokacin jagora, da buƙatun jigilar kaya.
- Bi umarnin masana’anta da mafi kyawun hanyoyin aiki yayin girkawa.
Isarwa da Mayar da Kaya
Kayayyakin da ke cikin sito yawanci ana tura su a cikin wannan ranar aikin. Ga kayayyakin da ba sa cikin sito a yanzu, lokacin tura su na iya bambanta bisa ga samuwa. Ana ba da jigilar kaya zuwa ƙasashen waje, kuma ana ƙididdige kuɗin jigila bisa wurin da ake aikawa, nauyi, da kamfanin sufuri da aka zaɓa.
Ana karɓar mayar da kaya cikin kwanaki 30 bayan karɓa, muddin kayan ba a yi amfani da su ba kuma suna cikin yanayin da suka fito daga masana’anta. Kuɗin jigilar mayar da kaya nauyi ne a kan abokin ciniki. Da fatan za a tuntube mu kafin ku mayar da duk wani kaya domin samun izinin mayarwa.
Don ƙarin bayani, don Allah ku duba Manufar Jigila & Mayar da Kaya.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Isarwa cikin gaggawa
Sassan kayan otomeshan na masana’antu na ainihi suna nan a shirye don aikawa cikin gaggawa a ko’ina cikin duniya.
-
Mayar da kaya cikin sauƙi
Tallafin mayar da kaya na kwanaki 30 tare da garantin watanni 12 don tabbatacciyar kariya bayan saye.
-
Taimako a kowane lokaci (24/7)
Tallafin ƙwararru mai saurin amsawa don taimakawa kiyaye ayyuka cikin kwanciyar hankali da inganci.
-
Na Gaskiya & Asali
Kashi 100% na asali ne, ana samar da su kai tsaye daga amintattun masana’antun kayan sarrafa masana’antu.
Jagorar Fasaha da Siyarwa
-
Can Eddy-Current Probes Prevent LNG Compressor Shutdowns?
This technical article examines how Bently Nevada eddy-current proximity probes provide high-precision vibration...
-
Can SIL 3 PLCs Really Slash $1M in Annual Offshore Maintenance?
This technical article examines how Allen‑Bradley GuardPLC SIL 3 safety controllers reduce unplanned offshore downtim...
-
Can Emerson DeltaV DCS Cards Optimize Chemical Safety Loops?
This technical article examines how Emerson DeltaV DCS card upgrades address legacy control limitations in chemical p...
-
Is Partial CNC Board Replacement Better Than a Full System Upgrade?
This technical article examines the dominance of GE Fanuc CNC hardware in heavy-duty automation, supported by field d...
-
Can Genuine PLC Modules Cut DCS Downtime 60%?
This article examines how genuine Allen-Bradley PLC module replacement strategies directly reduce unplanned DCS downt...
-
Is Your GE Fanuc PLC Talking to ABB DCS?
This article reveals how cross-system data silos between GE Fanuc PLC and ABB DCS cause 8–15% production losses in pr...