Canza gidanka da sabbin hanyoyin na’urorin lantarki masu yawa, daga hasken wuta mai hankali zuwa inganta ayyukanka da Bently Nevada 3500 Monitoring System, wanda ke ba da sa ido a ainihin lokaci kan girgiza da yanayin na’urorin injina don hana gazawa da ƙara lokacin aiki, da na’urorin da ake sarrafa su da murya duk an ƙera su ne don sauƙaƙa rayuwa, ƙara tsaro, da ƙarfafa haɗin kai.
SKU:IC200ERM001C
GE Fanuc IC200ERM001 VersaMax Isolated Expansion Receiver
Manufacturer: General Electric
Product No.: IC200ERM001C
Product Type: Expansion Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 700g
Shipping port: Xiamen
Warranty: 12 months
Raba
- Isarwa Cikin Gaggawa
- Tallafi na awa 24 a rana, kwana 7 a mako
- Tabbacin Inganci
Bayani
Product Overview
The GE Fanuc IC200ERM001 is a high-performance Isolated Expansion Receiver Module belonging to the versatile VersaMax series. This module is specifically designed to facilitate communication between expansion racks in a PLC system, providing robust electrical isolation to protect sensitive backplane components from noise and electrical surges.
Engineered for industrial reliability, this unit features two 26-pin female D-shell ports for seamless interconnection. With a net weight of 0.7 kg (1.54 lb) and a compact DIN rail mountable design, it provides power and communication status indicators to simplify system diagnostics and maintenance.
Technical Specifications
| Attribute | Technical Data |
|---|---|
| Manufacturer | GE Fanuc / GE Intelligent Platforms |
| Model Number | IC200ERM001 |
| Backplane Output | 3.3 VDC to 5 VDC |
| Current Rating | 1 A per channel |
| Interface Ports | 2 x 26-pin Female D-Shell |
| Temperature Range | 0°C to +60°C |
Key Performance Features
- Effective Signal Isolation: Provides a dedicated isolated bridge for expansion I/O racks, ensuring that electrical interference does not propagate across the PLC backplane.
- Real-Time Diagnostics: Features integrated LED indicators for both power status and communication activity, allowing for rapid troubleshooting in the field.
- Flexible Output Range: Supports backplane output voltages between 3.3V and 5V, ensuring compatibility with a wide range of VersaMax I/O modules.
- Certified Industrial Build: Fully UL Listed and CE Marked, meeting global safety and electromagnetic compatibility standards for harsh environments.
Installation & Mounting
The IC200ERM001 is designed for standard DIN rail mounting, ensuring a secure and vibration-resistant installation within industrial control panels. The module's dimensions (4.7 in x 4.5 in x 3.0 in) allow for high-density rack configurations. When connecting expansion cables to the dual D-shell ports, ensure the 26-pin connectors are fully seated and secured to maintain signal integrity.
Technical FAQs
Q1: What is the primary function of the "Isolated" feature?
A1: The isolation prevents ground loops and protects the main CPU rack from electrical faults that might occur in remote expansion racks.
Q2: Does this module require external power?
A2: No, it typically draws power from the expansion rack's power supply to drive the local backplane and communication circuits.
Q3: Can I use standard D-shell cables with this module?
A3: It is highly recommended to use the specific GE Fanuc expansion cables designed for the VersaMax series to ensure proper shielding and pin-out compatibility.
Condition: New & Original in Factory Packing
Warranty: 12 Months Factory Warranty
Ƙarin ƙayyadaddun bayanai
Sikeli (V/f)
Vector
mai amfani da wutar AC
Jagorar Sayi
- Tabbatar da ainihin samfurin, lambar ɓangare, da ƙayyadaddun bayanai kafin yin oda.
- Tabbatar da jituwa da injin ko tsarin kula da kake amfani da su a yanzu.
- Tuntuɓe mu ta sale@etowonauto.com ko +8617859788089 don taimakon fasaha.
- Duba zaɓuɓɓukan isarwa, lokacin jagora, da buƙatun jigilar kaya.
- Bi umarnin masana’anta da mafi kyawun hanyoyin aiki yayin girkawa.
Isarwa da Mayar da Kaya
Kayayyakin da ke cikin sito yawanci ana tura su a cikin wannan ranar aikin. Ga kayayyakin da ba sa cikin sito a yanzu, lokacin tura su na iya bambanta bisa ga samuwa. Ana ba da jigilar kaya zuwa ƙasashen waje, kuma ana ƙididdige kuɗin jigila bisa wurin da ake aikawa, nauyi, da kamfanin sufuri da aka zaɓa.
Ana karɓar mayar da kaya cikin kwanaki 30 bayan karɓa, muddin kayan ba a yi amfani da su ba kuma suna cikin yanayin da suka fito daga masana’anta. Kuɗin jigilar mayar da kaya nauyi ne a kan abokin ciniki. Da fatan za a tuntube mu kafin ku mayar da duk wani kaya domin samun izinin mayarwa.
Don ƙarin bayani, don Allah ku duba Manufar Jigila & Mayar da Kaya.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Isarwa cikin gaggawa
Sassan kayan otomeshan na masana’antu na ainihi suna nan a shirye don aikawa cikin gaggawa a ko’ina cikin duniya.
-
Mayar da kaya cikin sauƙi
Tallafin mayar da kaya na kwanaki 30 tare da garantin watanni 12 don tabbatacciyar kariya bayan saye.
-
Taimako a kowane lokaci (24/7)
Tallafin ƙwararru mai saurin amsawa don taimakawa kiyaye ayyuka cikin kwanciyar hankali da inganci.
-
Na Gaskiya & Asali
Kashi 100% na asali ne, ana samar da su kai tsaye daga amintattun masana’antun kayan sarrafa masana’antu.
Jagorar Fasaha da Siyarwa
-
Stop 68% of DCS Faults with Proven Transmitter Matching Rules?
This article presents field-verified solutions for optimizing communication between Rosemount transmitters and Emerso...
-
What Does Poor PLC Backup Cost Your Paper Plant?
This technical article presents quantified backup and recovery standards for GE Fanuc RX7i PLCs in high-capacity pape...
-
Why Do 42% of Offshore DCS Downtime Events Trace to Power Modules?
This technical analysis examines the root causes of Allen‑Bradley power module failures in offshore control cabi...
-
Can Layered PLC Fix Chemical Batch Failures?
This technical article presents field-validated ABB AC800M configuration strategies for high-stability fine chemical ...
-
How to Select GE Fanuc 90-30 Spare Parts for Hot Rolling Mills?
This article provides a technical guide for selecting and managing GE Fanuc Series 90-30 PLC spare parts in meta...
-
How Does Bently Nevada 3500 Reduce Unplanned Turbine Trips?
This technical article analyzes the quantitative value of the Bently Nevada 3500 TSI system in thermal power shaft pr...
