Canza gidanka da sabbin hanyoyin na’urorin lantarki masu yawa, daga hasken wuta mai hankali zuwa inganta ayyukanka da Bently Nevada 3500 Monitoring System, wanda ke ba da sa ido a ainihin lokaci kan girgiza da yanayin na’urorin injina don hana gazawa da ƙara lokacin aiki, da na’urorin da ake sarrafa su da murya duk an ƙera su ne don sauƙaƙa rayuwa, ƙara tsaro, da ƙarfafa haɗin kai.
SKU:369B1844G0019
GE 369B1844G0019 | Analog Input Unit 4-20mA -10-10V
Manufacturer: General Electric
Product No.: 369B1844G0019
Product Type: Digital Output Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 350g
Shipping port: Xiamen
Warranty: 12 months
Raba
- Isarwa Cikin Gaggawa
- Tallafi na awa 24 a rana, kwana 7 a mako
- Tabbacin Inganci
Bayani
GE 369B1844G0019 Digital Output Card
Product Overview
The GE 369B1844G0019 is a digital output card designed for industrial control systems. It functions as an analog input (AI) unit that converts continuous analog signals from sensors (temperature, pressure, speed, flow, displacement) into digital signals for PLC processing. The module supports standard analog input levels including -10 to +10V, 0 to 10V, 1 to 5V voltage signals and 4 to 20mA current signals. Weight is 0.35 kg.
Specifications
| Parameter | Value |
|---|---|
| Brand | GE Nexus |
| Model | 369B1844G0019 |
| Product Type | Digital Output Card / Analog Input Unit |
| Input Voltage Signal Range | -10 to +10V, 0 to 10V, 1 to 5V |
| Input Current Signal Range | 4 to 20 mA |
| Signal Processing | A/D Conversion with Optical Isolation |
| Interface Type | I/O Expansion Interface |
| Key Components | Signal Processing, Multiplexer, A/D Converter, Optocoupler Isolation |
| Weight | 0.35 kg |
Key Features
- Converts analog sensor signals to digital data for PLC processing
- Supports voltage inputs: -10 to +10V, 0 to 10V, 1 to 5V
- Supports current inputs: 4 to 20mA
- Integrated signal processing and multiplexing
- A/D converter for high-precision digital conversion
- Optocoupler isolation for signal integrity and protection
- I/O expansion interface for system scalability
- Compatible with GE XDPS-400e control system
Functional Description
The 369B1844G0019 analog input unit captures continuous analog signals from industrial sensors measuring temperature, pressure, speed, flow, and displacement. These signals are processed through signal conditioning, multiplexed via a multi-channel switch, converted to digital format by the A/D converter, and isolated through optocouplers before being transmitted to the CPU. The I/O expansion interface allows connection to additional I/O units when system point counts exceed the main PLC capacity.
Installation Notes
Install the module in the designated slot of the XDPS-400e rack. Ensure proper wiring for voltage or current inputs based on sensor output type. For current signals, ensure loop power is supplied externally. Use shielded cables for analog signals to minimize noise interference. Configure input range settings via system software prior to operation.
FAQs
Q1: What types of input signals does this module accept?
A1: Voltage signals: -10 to +10V, 0 to 10V, 1 to 5V. Current signals: 4 to 20mA.
Q2: What is the purpose of the I/O expansion interface?
A2: It allows connection of additional I/O expansion units when the system requires more input/output points than the main PLC provides.
Q3: What isolation method is used on this module?
A3: Optocoupler isolation is used to protect the CPU and maintain signal integrity between field devices and the control system.
Ƙarin ƙayyadaddun bayanai
Sikeli (V/f)
Vector
mai amfani da wutar AC
Jagorar Sayi
- Tabbatar da ainihin samfurin, lambar ɓangare, da ƙayyadaddun bayanai kafin yin oda.
- Tabbatar da jituwa da injin ko tsarin kula da kake amfani da su a yanzu.
- Tuntuɓe mu ta sale@etowonauto.com ko +8617859788089 don taimakon fasaha.
- Duba zaɓuɓɓukan isarwa, lokacin jagora, da buƙatun jigilar kaya.
- Bi umarnin masana’anta da mafi kyawun hanyoyin aiki yayin girkawa.
Isarwa da Mayar da Kaya
Kayayyakin da ke cikin sito yawanci ana tura su a cikin wannan ranar aikin. Ga kayayyakin da ba sa cikin sito a yanzu, lokacin tura su na iya bambanta bisa ga samuwa. Ana ba da jigilar kaya zuwa ƙasashen waje, kuma ana ƙididdige kuɗin jigila bisa wurin da ake aikawa, nauyi, da kamfanin sufuri da aka zaɓa.
Ana karɓar mayar da kaya cikin kwanaki 30 bayan karɓa, muddin kayan ba a yi amfani da su ba kuma suna cikin yanayin da suka fito daga masana’anta. Kuɗin jigilar mayar da kaya nauyi ne a kan abokin ciniki. Da fatan za a tuntube mu kafin ku mayar da duk wani kaya domin samun izinin mayarwa.
Don ƙarin bayani, don Allah ku duba Manufar Jigila & Mayar da Kaya.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Isarwa cikin gaggawa
Sassan kayan otomeshan na masana’antu na ainihi suna nan a shirye don aikawa cikin gaggawa a ko’ina cikin duniya.
-
Mayar da kaya cikin sauƙi
Tallafin mayar da kaya na kwanaki 30 tare da garantin watanni 12 don tabbatacciyar kariya bayan saye.
-
Taimako a kowane lokaci (24/7)
Tallafin ƙwararru mai saurin amsawa don taimakawa kiyaye ayyuka cikin kwanciyar hankali da inganci.
-
Na Gaskiya & Asali
Kashi 100% na asali ne, ana samar da su kai tsaye daga amintattun masana’antun kayan sarrafa masana’antu.
Jagorar Fasaha da Siyarwa
-
How to Diagnose Yokogawa CENTUM VP FCS Redundancy Faults?
This article explains how industrial automation teams can diagnose and debug Yokogawa CENTUM VP FCS controller redund...
-
How Does Siemens S7-1500 PLC Handle PROFINET Real-Time Jitter?
This article examines measurable PROFINET fault modes on Siemens S7-1500 PLC controllers and provides field-prov...
-
Why Do ABB AC800M Redundancy Mismatch Faults Keep Returning?
ABB AC800M redundancy mismatch faults account for 42.7 percent of controller alarms in 800xA systems. Most stem ...
-
How Does Honeywell C300 Improve on C200 DCS Controllers?
Honeywell C300 controllers deliver major gains over C200 in memory, scan speed, redundancy switching, and reliability...
-
How Does the 1756-RM2 Redundancy Module Work?
This article explains how to install, configure and tune the Allen-Bradley 1756-RM2 redundancy module for Contro...
-
How Do You Migrate DeltaV Classic DCS Without Plant Shutdown?
This article explains why Emerson DeltaV Classic systems reach technical limits after 15 to 20 years and how plants c...