Canza gidanka da sabbin hanyoyin na’urorin lantarki masu yawa, daga hasken wuta mai hankali zuwa inganta ayyukanka da Bently Nevada 3500 Monitoring System, wanda ke ba da sa ido a ainihin lokaci kan girgiza da yanayin na’urorin injina don hana gazawa da ƙara lokacin aiki, da na’urorin da ake sarrafa su da murya duk an ƙera su ne don sauƙaƙa rayuwa, ƙara tsaro, da ƙarfafa haɗin kai.
SKU:X20DM9324
B&R X20DM9324 Sink Input Source Output
Manufacturer: B&R
Product No.: X20DM9324
Product Type: I/O Module
Product Origin: AT
Payment:T/T, Western Union
Weight: 500g
Shipping port: Xiamen
Warranty: 12 months
Raba
- Isarwa Cikin Gaggawa
- Tallafi na awa 24 a rana, kwana 7 a mako
- Tabbacin Inganci
Bayani
B&R X20DM9324 8DI 4DO Digital Module with 1-Wire Connections
B&R X20DM9324 provides 8 digital inputs and 4 digital outputs for 1-wire connections. Inputs use sink configuration while outputs use source configuration. Features configurable software filter and integrated output protection.
I/O Specifications
- 8 digital inputs: Sink connections
- 4 digital outputs: Source connections
- 1-wire connection technology
- Nominal voltage: 24 VDC
- Configurable software input filter for entire module
- Integrated output protection
Diagnostics & Status
- B&R ID code: 0x20B9
- Status indicators per channel for I/O function
- Operating state and module status LEDs
- Diagnostics via LED and software for module run/error
- Output error status via LED and software
Power Consumption
- Bus power: 0.21 W
- Internal I/O power: 0.5 W
- Additional actuator power dissipation: +0.21 W (resistive)
Package Includes
- B&R X20DM9324 digital module unit
- Documentation and quick start guide
Shipping
- FedEx, UPS, DHL worldwide with tracking
FAQ
What connection type does this module use?
1-wire connections for both inputs and outputs.
Are inputs sink or source?
Inputs are sink connections. Outputs are source connections.
Can I filter input noise?
Yes. Configurable software filter applies to all inputs.
Ƙarin ƙayyadaddun bayanai
- Fari
- Baƙi
- Launin toka
Sikeli (V/f)
Vector
mai amfani da wutar AC
Jagorar Sayi
- Tabbatar da ainihin samfurin, lambar ɓangare, da ƙayyadaddun bayanai kafin yin oda.
- Tabbatar da jituwa da injin ko tsarin kula da kake amfani da su a yanzu.
- Tuntuɓe mu ta sale@etowonauto.com ko +8617859788089 don taimakon fasaha.
- Duba zaɓuɓɓukan isarwa, lokacin jagora, da buƙatun jigilar kaya.
- Bi umarnin masana’anta da mafi kyawun hanyoyin aiki yayin girkawa.
Isarwa da Mayar da Kaya
Kayayyakin da ke cikin sito yawanci ana tura su a cikin wannan ranar aikin. Ga kayayyakin da ba sa cikin sito a yanzu, lokacin tura su na iya bambanta bisa ga samuwa. Ana ba da jigilar kaya zuwa ƙasashen waje, kuma ana ƙididdige kuɗin jigila bisa wurin da ake aikawa, nauyi, da kamfanin sufuri da aka zaɓa.
Ana karɓar mayar da kaya cikin kwanaki 30 bayan karɓa, muddin kayan ba a yi amfani da su ba kuma suna cikin yanayin da suka fito daga masana’anta. Kuɗin jigilar mayar da kaya nauyi ne a kan abokin ciniki. Da fatan za a tuntube mu kafin ku mayar da duk wani kaya domin samun izinin mayarwa.
Don ƙarin bayani, don Allah ku duba Manufar Jigila & Mayar da Kaya.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Isarwa cikin gaggawa
Sassan kayan otomeshan na masana’antu na ainihi suna nan a shirye don aikawa cikin gaggawa a ko’ina cikin duniya.
-
Mayar da kaya cikin sauƙi
Tallafin mayar da kaya na kwanaki 30 tare da garantin watanni 12 don tabbatacciyar kariya bayan saye.
-
Taimako a kowane lokaci (24/7)
Tallafin ƙwararru mai saurin amsawa don taimakawa kiyaye ayyuka cikin kwanciyar hankali da inganci.
-
Na Gaskiya & Asali
Kashi 100% na asali ne, ana samar da su kai tsaye daga amintattun masana’antun kayan sarrafa masana’antu.
Jagorar Fasaha da Siyarwa
-
Stop 68% of DCS Faults with Proven Transmitter Matching Rules?
This article presents field-verified solutions for optimizing communication between Rosemount transmitters and Emerso...
-
What Does Poor PLC Backup Cost Your Paper Plant?
This technical article presents quantified backup and recovery standards for GE Fanuc RX7i PLCs in high-capacity pape...
-
Why Do 42% of Offshore DCS Downtime Events Trace to Power Modules?
This technical analysis examines the root causes of Allen‑Bradley power module failures in offshore control cabi...
-
Can Layered PLC Fix Chemical Batch Failures?
This technical article presents field-validated ABB AC800M configuration strategies for high-stability fine chemical ...
-
How to Select GE Fanuc 90-30 Spare Parts for Hot Rolling Mills?
This article provides a technical guide for selecting and managing GE Fanuc Series 90-30 PLC spare parts in meta...
-
How Does Bently Nevada 3500 Reduce Unplanned Turbine Trips?
This technical article analyzes the quantitative value of the Bently Nevada 3500 TSI system in thermal power shaft pr...