Canza gidanka da sabbin hanyoyin na’urorin lantarki masu yawa, daga hasken wuta mai hankali zuwa inganta ayyukanka da Bently Nevada 3500 Monitoring System, wanda ke ba da sa ido a ainihin lokaci kan girgiza da yanayin na’urorin injina don hana gazawa da ƙara lokacin aiki, da na’urorin da ake sarrafa su da murya duk an ƙera su ne don sauƙaƙa rayuwa, ƙara tsaro, da ƙarfafa haɗin kai.
SKU:6ES7455-1VS00-0AE0
6ES7455-1VS00-0AE0 Siemens | FM 455 S Step and Pulse
Manufacturer: Siemens
Product No.: 6ES7455-1VS00-0AE0
Product Type: Control Module
Product Origin: DE
Payment:T/T, Western Union
Weight: 1400g
Shipping port: Xiamen
Warranty: 12 months
Raba
- Isarwa Cikin Gaggawa
- Tallafi na awa 24 a rana, kwana 7 a mako
- Tabbacin Inganci
Bayani
Product Overview
The Siemens 6ES7455-1VS00-0AE0 is an FM 455 S control module for SIMATIC S7-400 systems, providing 16 step and pulse control channels. It combines 16 analog inputs, 16 digital inputs, and 32 digital outputs in a single module. Weighing approximately 1,400 g, this controller supports thermocouples, Pt100 resistance thermometers, and standard signals for comprehensive process control with pulse output capability.
Technical Configuration
This module operates from 24 V DC load voltage with a permissible range of 20.4 to 28.8 V. It draws a maximum of 400 mA (typical 330 mA) from load voltage without load. The 16 analog inputs accept thermocouples or 2-wire connections, while 8 channels support Pt100 or 4-wire connections. The 32 digital outputs feature electronic short-circuit protection and inductive shutdown voltage limitation to L+ (-1.5 V). Potential separation between channels and backplane bus uses optocouplers, tested at 500 V DC isolation.
Technical Specifications
| Parameter | Value |
|---|---|
| Manufacturer | Siemens |
| Part Number | 6ES7455-1VS00-0AE0 |
| Product Type | FM 455 S Control Module |
| Series | SIMATIC S7-400 |
| Control Channels | 16 step and pulse |
| Load Voltage | 24 V DC (20.4-28.8 V) |
| Current from L+ (No Load) | Max 400 mA, typ. 330 mA |
| Power Loss | Typ. 10.7 W, max 16.2 W |
| Digital Inputs | 16, 24 V DC (IEC 61131 type 2) |
| DI Signal "0" / "1" | -3 to +5 V / 13 to 30 V (7 mA typical) |
| Digital Outputs | 32, electronic short-circuit protection |
| Output Current (Rated) | 0.1 A (5-150 mA range, 0-60 °C) |
| Load Resistance Range | 240 Ω to 4 kΩ |
| Lamp Load | Max 5 W |
| Switching Frequency | Max 100 Hz resistive/lamps, 0.5 Hz inductive |
| Analog Inputs | 16 (8 with Pt100/4-wire) |
| Voltage Input Ranges | 0 to +10 V, -1.75 to +11.75 V, -80 to +80 mV |
| Current Input Ranges | 0-20 mA, 0-23.5 mA, -3.5 to +23.5 mA, 4-20 mA |
| Thermocouple Types | B, J, K, R, S |
| RTD Type | Pt100 |
| Resolution | 12 or 14 bit, parameterizable |
| Closed-Loop Controllers | 16 |
| Isolation Tested | 500 V DC |
| Dimensions (W x H x D) | 50 x 290 x 210 mm |
| Weight | Approx. 1,400 g |
| Front Connector | 2 x 48-pin required |
Installation Guide
Install the FM 455 S module in a compatible S7-400 rack slot and secure both 48-pin front connectors. Connect 24 V DC load voltage within the 20.4-28.8 V range. Use shielded cable for analog signals with maximum 200 m length (50 m for 80 mV and thermocouple inputs). Verify digital output loads fall within the 240 Ω to 4 kΩ resistance range. Internal or external Pt100 temperature compensation is parameterizable for thermocouple measurements.
Engineering Advantages
This module integrates 16 closed-loop controllers with 16 AI, 16 DI, and 32 DO in a single unit, combining step/pulse control with analog measurement. The 32 digital outputs provide twice the output density of the FM 455 C, reducing module count in high-channel applications. Electronic short-circuit protection and inductive shutdown voltage limitation safeguard connected loads. Parameterizable 12-bit or 14-bit resolution suits both standard and precision measurement tasks. Optocoupler isolation between channels and backplane bus protects the system from field transients.
Technical FAQs
Q1: How many digital outputs does the 6ES7455-1VS00-0AE0 provide?
A1: This FM 455 S module provides 32 digital outputs with electronic short-circuit protection, plus 16 analog inputs, 16 digital inputs, and 16 closed-loop controllers.
Q2: What is the digital output load resistance range?
A2: Digital outputs operate with load resistance from 240 Ω to 4 kΩ, with rated output current of 0.1 A (5-150 mA range at 0-60 °C).
Q3: What temperature sensor types does this module accept?
A3: It accepts thermocouple types B, J, K, R, and S, plus Pt100 resistance thermometers with parameterizable internal or external compensation.
Ƙarin ƙayyadaddun bayanai
Sikeli (V/f)
Vector
mai amfani da wutar AC
Jagorar Sayi
- Tabbatar da ainihin samfurin, lambar ɓangare, da ƙayyadaddun bayanai kafin yin oda.
- Tabbatar da jituwa da injin ko tsarin kula da kake amfani da su a yanzu.
- Tuntuɓe mu ta sale@etowonauto.com ko +8617859788089 don taimakon fasaha.
- Duba zaɓuɓɓukan isarwa, lokacin jagora, da buƙatun jigilar kaya.
- Bi umarnin masana’anta da mafi kyawun hanyoyin aiki yayin girkawa.
Isarwa da Mayar da Kaya
Kayayyakin da ke cikin sito yawanci ana tura su a cikin wannan ranar aikin. Ga kayayyakin da ba sa cikin sito a yanzu, lokacin tura su na iya bambanta bisa ga samuwa. Ana ba da jigilar kaya zuwa ƙasashen waje, kuma ana ƙididdige kuɗin jigila bisa wurin da ake aikawa, nauyi, da kamfanin sufuri da aka zaɓa.
Ana karɓar mayar da kaya cikin kwanaki 30 bayan karɓa, muddin kayan ba a yi amfani da su ba kuma suna cikin yanayin da suka fito daga masana’anta. Kuɗin jigilar mayar da kaya nauyi ne a kan abokin ciniki. Da fatan za a tuntube mu kafin ku mayar da duk wani kaya domin samun izinin mayarwa.
Don ƙarin bayani, don Allah ku duba Manufar Jigila & Mayar da Kaya.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Isarwa cikin gaggawa
Sassan kayan otomeshan na masana’antu na ainihi suna nan a shirye don aikawa cikin gaggawa a ko’ina cikin duniya.
-
Mayar da kaya cikin sauƙi
Tallafin mayar da kaya na kwanaki 30 tare da garantin watanni 12 don tabbatacciyar kariya bayan saye.
-
Taimako a kowane lokaci (24/7)
Tallafin ƙwararru mai saurin amsawa don taimakawa kiyaye ayyuka cikin kwanciyar hankali da inganci.
-
Na Gaskiya & Asali
Kashi 100% na asali ne, ana samar da su kai tsaye daga amintattun masana’antun kayan sarrafa masana’antu.
Jagorar Fasaha da Siyarwa
-
When Should You Replace a Yokogawa Analog IO Card?
This article breaks down Yokogawa analog AI/AO card calibration tolerances, drift aging benchmarks, and formal replac...
-
What Performance Gains Does S7-1500 Offer Over Legacy S7 PLCs?
Legacy Siemens S7-300 and S7-400 PLCs face spare-part shortages, rising failure rates and limited network capability,...
-
What Logic Changes Cut SIS False Trips by 94%?
This article examines practical logic modification and parameter tuning methods for ABB 800xA HI SIL3 safety ins...
-
Why Do FTE Redundancy Failovers Lock Up in DCS?
Honeywell FTE delivers sub-500 ms failover for Experion PKS, yet field records show 38% of outages stem from installa...
-
How Does the Bently Nevada 3500/42M Vibration Module Drift?
This technical guide examines the Bently Nevada 3500/42M vibration module within industrial automation architect...
-
What Causes IC694MDL Fault Codes in GE RX3i PLC Systems?
This guide explains GE RX3i IC694MDL discrete I/O fault codes, key electrical parameters, ESD and torque requirements...