Canza gidanka da sabbin hanyoyin na’urorin lantarki masu yawa, daga hasken wuta mai hankali zuwa inganta ayyukanka da Bently Nevada 3500 Monitoring System, wanda ke ba da sa ido a ainihin lokaci kan girgiza da yanayin na’urorin injina don hana gazawa da ƙara lokacin aiki, da na’urorin da ake sarrafa su da murya duk an ƙera su ne don sauƙaƙa rayuwa, ƙara tsaro, da ƙarfafa haɗin kai.
SKU:5437-1124
5437-1124 Woodward Overspeed Device | 0-100kHz Input Range
Manufacturer: Woodward
Product No.: 5437-1124
Product Type: Protection Device
Product Origin: USA
Payment:T/T, Western Union
Weight: 1250g
Shipping port: Xiamen
Warranty: 12 months
Raba
- Isarwa Cikin Gaggawa
- Tallafi na awa 24 a rana, kwana 7 a mako
- Tabbacin Inganci
Bayani
5437-1124 Woodward Overspeed Protection Device
Product Overview
The 5437-1124 Woodward overspeed protection device delivers reliable speed monitoring and shutdown for turbines and rotating machinery. This compact unit accepts MPU or proximity probe inputs up to 100 kHz, providing 4-20 mA proportional output and dual relay contacts for trip and alarm functions. Engineered for demanding industrial environments, the 5437-1124 operates from -40 to 85 °C.
Core Advantages
Wide 24V dc supply range (18-32V). Dual independent setpoints for alarm and trip. Adjustable time delays from 0.1 to 10 seconds. LED status indicators for power, speed, and relay states. DIN-rail or panel mounting options. Reverse polarity and transient protection.
Technical Specifications
| Parameter | Value |
|---|---|
| Part Number | 5437-1124 |
| Supply Voltage | 24V dc (18-32V range) |
| Input Frequency Range | 0 to 100 kHz |
| Input Signal | MPU or proximity probe (50 mV to 30V) |
| Output Signal | 4-20 mA proportional to speed |
| Relay Contacts | 2x SPDT, 2A @ 250V ac / 30V dc |
| Setpoint Range | 0 to 100% of full scale |
| Time Delay | 0.1 to 10 seconds (adjustable) |
| Operating Temp | -40 to +85 °C |
| Enclosure Rating | IP65 (dust and water jet protected) |
| Dimensions | 90 x 22.5 x 114 mm |
| Weight | 1.25 kg |
Installation Quick Notes
Wiring: Use shielded twisted pair for MPU input; keep separate from power cables. Grounding: Single-point ground to avoid ground loops. Setpoint adjustment: Use front-panel trimpots or remote potentiometer (1k to 10k ohm). Mounting: DIN-rail (35mm) or direct panel mount with M4 screws.
Why Choose 5437-1124
Compact and cost-effective overspeed solution. Wide input frequency range supports most speed sensors. Independent trip and alarm relays enable tiered protection strategy. IP65 rating allows installation in washdown areas. Field-adjustable time delays prevent nuisance trips during transient overspeed events.
FAQs
Q1: What sensor types are compatible with the 5437-1124?
A1: Magnetic pickups (MPU) with 50 mV to 30V output, and proximity probes with NPN or PNP signals.
Q2: How do I set the trip point?
A2: Use the front-panel Setpoint 1 and Setpoint 2 trimpots. Each scales from 0 to 100% of the configured full-scale frequency.
Q3: Can the 4-20 mA output be scaled for different speed ranges?
A3: Yes. Adjust the zero and span potentiometers to map the input frequency to any 4-20 mA range within 0-100 kHz.
Ƙarin ƙayyadaddun bayanai
Sikeli (V/f)
Vector
mai amfani da wutar AC
Jagorar Sayi
- Tabbatar da ainihin samfurin, lambar ɓangare, da ƙayyadaddun bayanai kafin yin oda.
- Tabbatar da jituwa da injin ko tsarin kula da kake amfani da su a yanzu.
- Tuntuɓe mu ta sale@etowonauto.com ko +8617859788089 don taimakon fasaha.
- Duba zaɓuɓɓukan isarwa, lokacin jagora, da buƙatun jigilar kaya.
- Bi umarnin masana’anta da mafi kyawun hanyoyin aiki yayin girkawa.
Isarwa da Mayar da Kaya
Kayayyakin da ke cikin sito yawanci ana tura su a cikin wannan ranar aikin. Ga kayayyakin da ba sa cikin sito a yanzu, lokacin tura su na iya bambanta bisa ga samuwa. Ana ba da jigilar kaya zuwa ƙasashen waje, kuma ana ƙididdige kuɗin jigila bisa wurin da ake aikawa, nauyi, da kamfanin sufuri da aka zaɓa.
Ana karɓar mayar da kaya cikin kwanaki 30 bayan karɓa, muddin kayan ba a yi amfani da su ba kuma suna cikin yanayin da suka fito daga masana’anta. Kuɗin jigilar mayar da kaya nauyi ne a kan abokin ciniki. Da fatan za a tuntube mu kafin ku mayar da duk wani kaya domin samun izinin mayarwa.
Don ƙarin bayani, don Allah ku duba Manufar Jigila & Mayar da Kaya.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Isarwa cikin gaggawa
Sassan kayan otomeshan na masana’antu na ainihi suna nan a shirye don aikawa cikin gaggawa a ko’ina cikin duniya.
-
Mayar da kaya cikin sauƙi
Tallafin mayar da kaya na kwanaki 30 tare da garantin watanni 12 don tabbatacciyar kariya bayan saye.
-
Taimako a kowane lokaci (24/7)
Tallafin ƙwararru mai saurin amsawa don taimakawa kiyaye ayyuka cikin kwanciyar hankali da inganci.
-
Na Gaskiya & Asali
Kashi 100% na asali ne, ana samar da su kai tsaye daga amintattun masana’antun kayan sarrafa masana’antu.
Jagorar Fasaha da Siyarwa
-
Original vs Compatible GE Fanuc PLC Parts?
This guide presents a data-driven methodology for identifying and verifying brand-new, original GE Fanuc 90-30, 90-70...
-
Can Data-Driven Alarm Grading Reduce Turbine Downtime?
This technical article presents a data-driven four-tier alarm grading strategy for Bently Nevada 3500 systems in comb...
-
How does ABB S800 I/O hot swap cut unplanned downtime by 90%?
This article presents quantified operational best practices for ABB S800 I/O hot swap in 24/7 process industries. ...
-
Is Your Refinery DCS Ready for Zero-Trust OT Access Control?
This technical article examines data-driven cybersecurity hardening strategies for Emerson DeltaV DCS in refiner...
-
How to Quantify and Fix Allen‑Bradley HMI Flickering in Cement Plants?
This technical article presents quantified field data from 2021–2026 on Allen‑Bradley HMI flickering in cement plants...
-
How to Fix HMI Flickering Caused by Power Noise and Vibration?
This article presents quantified field data from 2021–2026 on Allen‑Bradley HMI flickering faults in cement productio...
