Canza gidanka da sabbin hanyoyin na’urorin lantarki masu yawa, daga hasken wuta mai hankali zuwa inganta ayyukanka da Bently Nevada 3500 Monitoring System, wanda ke ba da sa ido a ainihin lokaci kan girgiza da yanayin na’urorin injina don hana gazawa da ƙara lokacin aiki, da na’urorin da ake sarrafa su da murya duk an ƙera su ne don sauƙaƙa rayuwa, ƙara tsaro, da ƙarfafa haɗin kai.
SKU:369B1841G5006
369B1841G5006 GE Nexus Analog Input Module MAI50 4-20mA
Manufacturer: General Electric
Product No.: 369B1841G5006
Product Type: Analog Input Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 600g
Shipping port: Xiamen
Warranty: 12 months
Raba
- Isarwa Cikin Gaggawa
- Tallafi na awa 24 a rana, kwana 7 a mako
- Tabbacin Inganci
Bayani
Product Overview
The GE 369B1841G5006 Nexus Analog Input Module (MAI50) delivers 16 channels of high-precision analog signal acquisition. It supports 4-20mA and ±10V inputs, making it ideal for turbine and generator control systems. A powerful 32-bit processor ensures fast, accurate data conversion for critical monitoring applications.
Technical Configuration
This module features a high-performance 32-bit embedded processor and communicates via a redundant high-speed serial bus at 1 Mbps. The DB-9 connector ensures reliable I/O interfacing. Dual 24V DC power inputs provide 1:1 redundancy for maximum availability. It includes 16 single-ended analog input channels with 16-bit A/D conversion, grouped in two banks of 8 channels each.
Technical Specifications
| Parameter | Value |
|---|---|
| Model | 369B1841G5006 (MAI50) |
| Channels | 16 (single-ended) |
| Input Signals | ±10V, ±5V, 0(4)-20mA |
| A/D Conversion | 16-bit, 8 channels per group |
| Measurement Error | Max 0.1% |
| Power Supply | Dual 24V DC ±10% (1:1 redundant) |
| Power Consumption | Typical 3W, Max 5W |
| Isolation Voltage | 1500VAC (system), 500VAC (channel to ground) |
| CMRR / NMRR | >120dB / >60dB |
| Dimensions (H x W x D) | 209 x 129.5 x 51 mm |
| Weight | Approx. 0.6 kg |
| Operating Temperature | 0 to 60°C |
| Certification | CE (with system) |
Installation Guide
Mount the module using the provided screw terminals (2.5mm² wire capacity, dual-wire capable). Connect dual 24V DC power feeds for redundant operation. Use the DB-9 connector for serial bus communication. Ensure proper grounding and maintain cable segregation from high-voltage lines. Operate within 0-60°C temperature range and non-condensing humidity (10-90%).
Engineering Advantages
This module offers high accuracy (0.1%) and robust isolation (1500VAC system isolation). The 16-bit resolution ensures precise signal measurement. Dual power inputs guarantee continuous operation in critical turbine control loops. With CMRR >120dB and NMRR >60dB, it effectively rejects electrical noise in harsh industrial environments.
Technical FAQs
Q1: What input ranges does the 369B1841G5006 support?
A1: This module accepts ±10V, ±5V, 4-20mA, and 0-20mA signals. Over-range alarm is supported for all ranges except ±10V input.
Q2: How is the analog input isolation configured?
A2: Channel-to-channel isolation is 250VAC, channel-to-ground is 500VAC, and system isolation is 1500VAC. This provides excellent protection in high-voltage environments.
Q3: What is the power redundancy scheme?
A3: The module features dual 24V DC (±10%) inputs with 1:1 redundancy. If one power source fails, the other automatically takes over without interrupting operation.
Ƙarin ƙayyadaddun bayanai
Sikeli (V/f)
Vector
mai amfani da wutar AC
Jagorar Sayi
- Tabbatar da ainihin samfurin, lambar ɓangare, da ƙayyadaddun bayanai kafin yin oda.
- Tabbatar da jituwa da injin ko tsarin kula da kake amfani da su a yanzu.
- Tuntuɓe mu ta sale@etowonauto.com ko +8617859788089 don taimakon fasaha.
- Duba zaɓuɓɓukan isarwa, lokacin jagora, da buƙatun jigilar kaya.
- Bi umarnin masana’anta da mafi kyawun hanyoyin aiki yayin girkawa.
Isarwa da Mayar da Kaya
Kayayyakin da ke cikin sito yawanci ana tura su a cikin wannan ranar aikin. Ga kayayyakin da ba sa cikin sito a yanzu, lokacin tura su na iya bambanta bisa ga samuwa. Ana ba da jigilar kaya zuwa ƙasashen waje, kuma ana ƙididdige kuɗin jigila bisa wurin da ake aikawa, nauyi, da kamfanin sufuri da aka zaɓa.
Ana karɓar mayar da kaya cikin kwanaki 30 bayan karɓa, muddin kayan ba a yi amfani da su ba kuma suna cikin yanayin da suka fito daga masana’anta. Kuɗin jigilar mayar da kaya nauyi ne a kan abokin ciniki. Da fatan za a tuntube mu kafin ku mayar da duk wani kaya domin samun izinin mayarwa.
Don ƙarin bayani, don Allah ku duba Manufar Jigila & Mayar da Kaya.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Isarwa cikin gaggawa
Sassan kayan otomeshan na masana’antu na ainihi suna nan a shirye don aikawa cikin gaggawa a ko’ina cikin duniya.
-
Mayar da kaya cikin sauƙi
Tallafin mayar da kaya na kwanaki 30 tare da garantin watanni 12 don tabbatacciyar kariya bayan saye.
-
Taimako a kowane lokaci (24/7)
Tallafin ƙwararru mai saurin amsawa don taimakawa kiyaye ayyuka cikin kwanciyar hankali da inganci.
-
Na Gaskiya & Asali
Kashi 100% na asali ne, ana samar da su kai tsaye daga amintattun masana’antun kayan sarrafa masana’antu.
Jagorar Fasaha da Siyarwa
-
Why Do ABB AC800M Redundancy Mismatch Faults Keep Returning?
ABB AC800M redundancy mismatch faults account for 42.7 percent of controller alarms in 800xA systems. Most stem ...
-
How Does Honeywell C300 Improve on C200 DCS Controllers?
Honeywell C300 controllers deliver major gains over C200 in memory, scan speed, redundancy switching, and reliability...
-
How Does the 1756-RM2 Redundancy Module Work?
This article explains how to install, configure and tune the Allen-Bradley 1756-RM2 redundancy module for Contro...
-
How Do You Migrate DeltaV Classic DCS Without Plant Shutdown?
This article explains why Emerson DeltaV Classic systems reach technical limits after 15 to 20 years and how plants c...
-
What Makes Bently Nevada System 1 Essential for Predictive Maintenance?
Bently Nevada System 1 is a dedicated vibration analytics platform that pairs with 3500 TSI racks to deliver hig...
-
Is ABB MOD300 DCS Migration Still Worth the Investment?
ABB Advant MOD300 systems still run in many refineries and power plants, yet aging capacitors, scarce spares and hidd...
