Canza gidanka da sabbin hanyoyin na’urorin lantarki masu yawa, daga hasken wuta mai hankali zuwa inganta ayyukanka da Bently Nevada 3500 Monitoring System, wanda ke ba da sa ido a ainihin lokaci kan girgiza da yanayin na’urorin injina don hana gazawa da ƙara lokacin aiki, da na’urorin da ake sarrafa su da murya duk an ƙera su ne don sauƙaƙa rayuwa, ƙara tsaro, da ƙarfafa haɗin kai.
SKU:3500/65-01-00
3500/65-01-00 Bently Nevada Temperature Module for 3500 Rack
Manufacturer: Bently Nevada
Product No.: 3500/65-01-00
Product Type: Temperature Monitor
Product Origin: USA
Payment:T/T, Western Union
Weight: 910g
Shipping port: Xiamen
Warranty: 12 months
Raba
- Isarwa Cikin Gaggawa
- Tallafi na awa 24 a rana, kwana 7 a mako
- Tabbacin Inganci
Bayani
Product Overview
The 3500/65-01-00 145988-02 is a 16-channel temperature monitor for critical machinery. It accepts RTD and isolated-tip TC inputs, delivering precise temperature measurement for turbines and compressors. Designed for the 3500 rack, it ensures reliable thermal monitoring in harsh industrial environments.
Technical Configuration
I/O Module Type: 01 – Internal Terminations
The 01 suffix designates an RTD/Isolated Tip TC module with internal terminations. This eliminates external termination blocks, reducing wiring complexity. Supports 3-wire/4-wire RTDs (Pt100, Ni120, Cu10) and TC types E, J, K, T with built-in cold junction compensation.
Agency Approval: 00 – None
Standard version with no additional agency certifications. Complies with FCC, EMC (2014/30/EU), LV (2014/35/EU), and RoHS (2011/65/EU). Meets ABS and DNV GL marine rules without special approvals.
Technical Specifications
| Parameter | Specification |
|---|---|
| Input Channels | 1 to 16 RTD or isolated-tip TC |
| Input Impedance | >1 MΩ per lead |
| RTD Types | 100Ω Pt (α=0.00385 / 0.00392), 120Ω Ni, 10Ω Cu |
| TC Types | E, J, K, T |
| RTD Excitation | 913 ±7 µA @ 25°C |
| Resolution | 1°C or 1°F |
| Accuracy (Internal Termination) | ±3°C at +25°C (±5.4°F) |
| Cold Junction Compensation | ±2°C at +25°C (±3.6°F) |
| Alarm Setpoints | 0–100% full-scale, under & over |
| Alarm Delays | Alert: 1–60s (1s steps); Danger: 1–60s (0.5s steps) |
| Power Consumption | 3 W nominal |
| Operating Temperature | -30°C to +65°C (-22°F to +150°F) |
| Storage Temperature | -40°C to +85°C (-40°F to +185°F) |
| Dimensions (H x W x D) | 241.3 mm x 24.4 mm x 241.8 mm |
| Weight | 0.91 kg (2.0 lbs) |
| Rack Space | 1 full-height front slot |
Installation & Maintenance
Wiring & Termination
Internal termination eliminates external blocks. Use shielded twisted-pair cables (max 20Ω per lead for RTDs). Keep TC wires away from high-voltage cables and maintain a minimum bending radius of 10x cable diameter.
Configuration
Configure via 3500 Configuration Software (v3.85+). Set full-scale ranges, alarms, and delays per channel. No manual calibration required. Requires 3500/22 Firmware Rev 1.50+ and 3500/93 Rev 2.02+ for proper communication.
Engineering Advantages
Industrial Durability
Operates from -30°C to +65°C and stores at -40°C to +85°C. Galvanically isolated inputs resist ground loops and noise in power plants and process industries.
TSI Integration
Fully compatible with Bently Nevada's 3500 TSI ecosystem. Real-time temperature data acquisition with the same reliability as vibration monitoring modules.
Precision Alarms
Independent under/over setpoints per channel. Accuracy within 0.13% of desired value. Programmable delays prevent nuisance trips during transients.
Technical FAQs
Q1: Can I use external termination blocks with this module?
A1: No. External blocks are incompatible and will cause an I/O Module Mismatch error (562 ADC Failure). Use only internal terminations.
Q2: Which RTD connection is recommended for best accuracy?
A2: 4-wire RTDs provide the highest accuracy. Order with Modification 179952-01 when purchasing I/O modules for 4-wire use.
Q3: What firmware versions are required?
A3: 3500/22 Firmware Rev 1.50+, 3500/93 Rev 2.02+, 3500/01 Software v3.85+, and System 1 Software Rev 5.2 SP2+. Do not use 3500/02 or 3500/03.
Ƙarin ƙayyadaddun bayanai
Sikeli (V/f)
Vector
mai amfani da wutar AC
Jagorar Sayi
- Tabbatar da ainihin samfurin, lambar ɓangare, da ƙayyadaddun bayanai kafin yin oda.
- Tabbatar da jituwa da injin ko tsarin kula da kake amfani da su a yanzu.
- Tuntuɓe mu ta sale@etowonauto.com ko +8617859788089 don taimakon fasaha.
- Duba zaɓuɓɓukan isarwa, lokacin jagora, da buƙatun jigilar kaya.
- Bi umarnin masana’anta da mafi kyawun hanyoyin aiki yayin girkawa.
Isarwa da Mayar da Kaya
Kayayyakin da ke cikin sito yawanci ana tura su a cikin wannan ranar aikin. Ga kayayyakin da ba sa cikin sito a yanzu, lokacin tura su na iya bambanta bisa ga samuwa. Ana ba da jigilar kaya zuwa ƙasashen waje, kuma ana ƙididdige kuɗin jigila bisa wurin da ake aikawa, nauyi, da kamfanin sufuri da aka zaɓa.
Ana karɓar mayar da kaya cikin kwanaki 30 bayan karɓa, muddin kayan ba a yi amfani da su ba kuma suna cikin yanayin da suka fito daga masana’anta. Kuɗin jigilar mayar da kaya nauyi ne a kan abokin ciniki. Da fatan za a tuntube mu kafin ku mayar da duk wani kaya domin samun izinin mayarwa.
Don ƙarin bayani, don Allah ku duba Manufar Jigila & Mayar da Kaya.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Isarwa cikin gaggawa
Sassan kayan otomeshan na masana’antu na ainihi suna nan a shirye don aikawa cikin gaggawa a ko’ina cikin duniya.
-
Mayar da kaya cikin sauƙi
Tallafin mayar da kaya na kwanaki 30 tare da garantin watanni 12 don tabbatacciyar kariya bayan saye.
-
Taimako a kowane lokaci (24/7)
Tallafin ƙwararru mai saurin amsawa don taimakawa kiyaye ayyuka cikin kwanciyar hankali da inganci.
-
Na Gaskiya & Asali
Kashi 100% na asali ne, ana samar da su kai tsaye daga amintattun masana’antun kayan sarrafa masana’antu.
Jagorar Fasaha da Siyarwa
-
How Does TSI Integration Reduce Turbine False Trip Risks?
This article examines data-driven turbine safety monitoring and mechanical fault diagnosis within industrial automati...
-
Can turn-key automation services really cut plant downtime by 47%?
This article examines how fragmented PLC, DCS, TSI, and power-protection systems drive hidden operational losses in p...
-
Is Your Manufacturing Execution Still Stuck in Open-Loop Mode?
This article examines how closed-loop automated control resolves the critical disconnect between production planning ...
-
Can Predictive Analytics Cut Factory Automation Downtime?
This article examines how predictive abnormality pre-judgment technology addresses the economic burden of reactive fa...
-
Is Full PLC Replacement Best for Brown-Field Automation?
This technical article analyzes the hidden costs of full-scale PLC and DCS hardware replacement in brown-field plants...
-
Is Your DCS Logic Tuning Ready for Real-World Production Loads?
This article examines the critical role of physical on-site commissioning and logic tuning in industrial automation, ...