IC693PWR328 GE Fanuc 30W PLC Power Supply

Nur noch 10 Stück verfügbar
  • Manufacturer: General Electric

  • Product No.: IC693PWR328

  • Product Type: Power Supply Module

  • Product Origin: USA

  • Payment:T/T, Western Union

  • Weight: 520g

  • Shipping port: Xiamen

  • Warranty: 12 months

30-Tage-Rückgaberecht · 12 Monate Garantie
  • Schnelle Lieferung
  • Rund-um-die-Uhr Unterstützung
  • Qualitätssicherung

Beschreibung

Product Overview

The GE Fanuc IC693PWR328 is a high-efficiency, 30 Watt max output power supply module designed specifically for the Series 90-30 programmable logic controller (PLC) platform. Operating from a nominal 48 VDC input voltage source, this rugged module delivers highly regulated 5 VDC power to the local CPU alongside dual isolated and relay 24 VDC outputs. Weighing approximately 0.52 kg (1.15 lbs), this module occupies the leftmost slot of any standard Series 90-30 baseplate, serving as the stable electrical cornerstone for complex factory automation systems.

Core Technical Advantages

  • Multiple Isolated DC Outputs: Distributes independent 5 VDC and 24 VDC voltage rails to enable safe component separation, completely eliminating the risk of cross-module electrical damage.
  • Integrated RS-485 Serial Interface: Features a built-in RS-485 communication port that facilitates direct, high-speed connections to local programming PCs, operator interface terminals, or diagnostic tools.
  • Comprehensive Health Tracking: Equipped with 4 vivid front-panel LED status indicators that provide real-time hardware diagnostics, drastically simplifying field troubleshooting and fault detection.

Technical Specifications

Parameter Specification Details
Brand / Manufacturer GE Fanuc (Series 90-30 PLC System)
Model Part Number IC693PWR328
Gross Weight 0.52 kg (1.15 lbs)
Nominal Input Power 48 Volts DC
CPU Logic Power Output 5 Volts DC, 15 Watts capacity
Isolated Power Output 24 Volts DC, 20 Watts capacity
Relay Power Output 24 Volts DC, 15 Watts capacity
Total Rated Output Power 30 Watts Maximum combined load
Serial Interface RS-485 Serial Communication Port
Data Protection Internal battery compartment supporting a Lithium backup battery
Chassis Mounting Location Leftmost dedicated slot on the Series 90-30 baseplate backplane
Lifecycle Status Discontinued by manufacturer (Available as high-quality surplus stock)

Installation & Engineering Guide

  • Backplane Positioning: Ensure primary power feeds are completely isolated before installation. Always slide the 0.52 kg hardware frame into the leftmost slot position on the Series 90-30 baseplate, pushing backward firmly until the alignment pins snap the module connectors tightly to the backplane grid.
  • Battery Integration: Unlatch the front maintenance access panel and seat a fresh Lithium backup battery into the integrated compartment before running power. This initialization secures application logic states and prevents complete data loss across the CPU memory circuits during standard plant brownout conditions.
  • Output Power Budgeting: Calculate the aggregate power draw of your system modules prior to startup. Individual output tracks can handle up to 15 Watts (5V CPU / 24V Relay) and 20 Watts (24V Isolated), but the combined simultaneous power draw across all three rails must not exceed the absolute 30 Watts total output limit.

Technical FAQs

Q1: What problem does the isolated 24 VDC output loop solve for my field equipment?
A1: The isolated 24 VDC output circuit separates field instrumentation noise and ground loop potentials from the sensitive digital logic backplane, protecting internal PLC components against unexpected voltage spikes and external wiring failures.

Q2: Can the integrated RS-485 serial interface be used for continuous process monitoring?
A2: Yes. The onboard RS-485 port is fully optimized to maintain robust, continuous serial communications with local operator interfaces, host computers, or multi-drop diagnostic networks running standard automation protocols.

Q3: How does the module indicate internal circuit health and input power availability?
A3: The faceplate features a bank of 4 distinct diagnostic LED status indicators. These lamps illuminate in specific patterns to display real-time statuses regarding input line power availability, internal logic faults, and overall output rail functionality.

🏷️ Tags: Power Supply Module

Skalar (V/f)

Vektor

Netzbetrieben

  • Bestätigen Sie vor der Bestellung das genaue Modell, die Teilenummer und die Spezifikationen.
  • Stellen Sie die Kompatibilität mit Ihrer aktuellen Maschine oder Steuerung sicher.
  • Kontaktieren Sie uns für technische Unterstützung unter sale@etowonauto.com oder +8617859788089.
  • Überprüfen Sie Lieferoptionen, Lieferzeiten und Versandanforderungen.
  • Folgen Sie bei der Installation den Herstelleranweisungen und bewährten Verfahren.

Vorrätige Artikel werden in der Regel noch am selben Werktag versandt. Bei Produkten, die derzeit nicht auf Lager sind, können die Versandzeiten je nach Verfügbarkeit variieren. Internationaler Versand ist möglich, und die Versandkosten werden basierend auf Zielort, Gewicht und gewähltem Versanddienstleister berechnet.

Rücksendungen werden innerhalb von 30 Tagen nach Erhalt akzeptiert, vorausgesetzt, die Artikel sind unbenutzt und im Originalzustand. Die Rücksendekosten trägt der Kunde. Bitte kontaktieren Sie uns vor der Rücksendung eines Artikels, um eine Rücksendegenehmigung zu erhalten.

Für weitere Details lesen Sie bitte unsere Versand- & Rückgaberichtlinie.

Vollständige Details anzeigen

SICHERN SIE ZUVERLÄSSIGE MASCHINENLEISTUNG

Verwandeln Sie Ihr Zuhause mit den neuesten Multi-Elektronik-Lösungen, von intelligenter Beleuchtung bis hin zu sprachgesteuerten Geräten – alle darauf ausgelegt, das Leben einfacher, sicherer und vernetzter zu machen. Optimieren Sie Ihre Abläufe mit dem Bently Nevada 3500 Überwachungssystem, das eine Echtzeit-Überwachung von Vibrationen und Maschinenzuständen bietet, um Ausfälle zu verhindern und die Betriebszeit zu maximieren.