Chuyển đến nội dung
Phụ tùng tự động hóa, cung cấp toàn cầu
Chuyển đến thông tin sản phẩm
1 trong số 3

SKU:IS215ACLEH1B

GE IS215ACLEH1B ACLE Module Mark VI EX2100 Control

Còn hàng (20 đơn vị), sẵn sàng để giao hàng
  • Manufacturer: General Electric

  • Product No.: IS215ACLEH1B

  • Product Type: Circuit Board

  • Product Origin: USA

  • Payment:T/T, Western Union

  • Weight: 570g

  • Shipping port: Xiamen

  • Warranty: 12 months

Chính sách đổi trả trong 30 ngày · Bảo hành 12 tháng
  • Giao hàng nhanh
  • Hỗ trợ 24/7
  • Đảm bảo chất lượng

Mô tả

Product Overview

The GE Energy IS215ACLEH1B (Functional Acronym: ACLE) is a high-performance Application Control Layer Module designed for General Electric's Mark VI Speedtronic Gas Turbine Control Systems and EX2100 / EX2100e Excitation Control Systems. Engineered for critical industrial control applications, this microprocessor-based controller manages real-time turbine control logic, subsystem coordination, complex communication protocols, and system diagnostics.

Featuring an "IS215" domestic special modular assembly prefix, the IS215ACLEH1B is built with a dual-slot metal faceplate tailored for standard GE VME rack structures and control cabinets. Operating with a 125 V DC input voltage and 24 V DC output, it incorporates a high-speed PCI controller, 128 KB L2 cache, 10BaseT RJ45 Ethernet communication, non-volatile flash memory, and an array of front-panel LED status indicators. Weighing approximately 0.57 kg (1.25 lbs), this Grade B functional revision module delivers robust online application loading and real-time control block processing across demanding energy environments.

Core Technical Advantages

  • Advanced Microprocessor & PCI Controller Architecture: Equipped with an onboard CPU, PCI controller, and 128 KB Level 2 cache to optimize data transfers and high-speed input/output processing.
  • Comprehensive Network & Bus Connectivity: Features 10BaseT RJ45 Ethernet (IRQ 5 initialization via BIOS) for seamless communication over ISBus networks, SCADA systems, and central control hubs.
  • Flexible Software & Logic Capabilities: Supports online application configuration loading, non-volatile flash memory storage, control block execution, and real-time forcing of I/O points and internal booleans.
  • VME Rack & Dual-Slot Integration: Engineered with a specialized installation faceplate that occupies two half-slots in standard EX2100 exciter board racks or Innovation Series drives.

Technical Specifications

Parameter Specification Details
Brand / Manufacturer General Electric / GE Energy
Full Catalog Part Number IS215ACLEH1B
Product Series Mark VI Series / EX2100 & EX2100e Excitation System
Functional Acronym ACLE (Application Control Layer)
Product Description Application Control Layer Module
Input / Output Voltage Input: 125 V DC | Output: 24 V DC
Operating Temperature Range -30°C to +65°C (-22°F to +149°F)
Cache Architecture Level 2, 128 KB (Controlled via PCI Controller)
Ethernet Port Type 10BaseT RJ45 Connector (Front Panel)
Mounting & Rack Form Factor VME Rack Structure / Occupies 2 Half-Slots (Faceplate)
Board Dimensions 23.495 cm (H) x 10.795 cm (W)
Functional Revision 1 B (Singular B-grade functional revision)
Country of Manufacture United States (USA)
Estimated Shipping Weight Approx. 0.57 kg (1.25 lbs)

Installation & Handling Guidelines

  • ESD Protection & Static Safety: Always handle the ACLE board using a grounded wrist strap and static-safe equipment to avoid damaging onboard microprocessors and flash memory ICs.
  • VME Rack Slot Insertion: Align the metal faceplate guide rails carefully into the two half-slots of the EX2100 exciter rack or Innovation drive cabinet before securing the faceplate retaining screws.
  • Ethernet & Cable Connection: Connect standard RJ45 Ethernet cabling directly to the front-panel 10BaseT port, ensuring correct pin alignment and cable strain relief within the cabinet.

Technical FAQs

Q1: What is the main function of the GE IS215ACLEH1B module in turbine control systems?
A1: It executes control logic, manages communication networks, enforces safety protocols, and coordinates subsystems.

Q2: How does the IS215ACLEH1B module mount within the control cabinet?
A2: It uses a metal installation faceplate designed to occupy two half-slots in standard EX2100 VME racks.

Q3: What Ethernet communication interface is featured on the front panel of the IS215ACLEH1B board?
A3: It features a 10BaseT RJ45 jack initialized by BIOS, managed via an onboard PCI controller.

  • Xanh lá cây

Vô hướng (V/f)

Vector

Chạy bằng điện xoay chiều

  • Xác nhận chính xác mẫu mã, số bộ phận và thông số kỹ thuật trước khi đặt hàng.
  • Đảm bảo tương thích với máy móc hoặc hệ thống điều khiển hiện tại của bạn.
  • Liên hệ qua sale@etowonauto.com hoặc +8617859788089 để được hỗ trợ kỹ thuật.
  • Xem xét các tùy chọn giao hàng, thời gian giao và yêu cầu vận chuyển.
  • Tuân theo hướng dẫn của nhà sản xuất và các thực hành tốt nhất trong quá trình lắp đặt.

Các mặt hàng có sẵn trong kho thường được gửi đi trong cùng ngày làm việc. Đối với các sản phẩm hiện không có sẵn, thời gian gửi hàng có thể thay đổi tùy theo tình trạng hàng. Vận chuyển quốc tế có sẵn, và chi phí vận chuyển được tính theo điểm đến, trọng lượng và lựa chọn nhà vận chuyển.

Chúng tôi chấp nhận trả hàng trong vòng 30 ngày kể từ khi nhận hàng, với điều kiện sản phẩm chưa sử dụng và còn nguyên trạng ban đầu. Chi phí vận chuyển trả hàng do khách hàng chịu trách nhiệm. Vui lòng liên hệ với chúng tôi trước khi trả bất kỳ mặt hàng nào để nhận được sự chấp thuận trả hàng.

Để biết thêm chi tiết, vui lòng xem lại Chính sách Vận chuyển & Trả hàng.

Xem toàn bộ chi tiết

ĐẢM BẢO HIỆU SUẤT MÁY MÓC ĐÁNG TIN CẬY

Biến đổi ngôi nhà của bạn với các giải pháp đa điện tử mới nhất, từ hệ thống chiếu sáng thông minh đến các thiết bị điều khiển bằng giọng nói, tất cả được thiết kế để làm cho cuộc sống trở nên dễ dàng hơn, an toàn hơn và kết nối hơn.

Tối ưu hóa hoạt động của bạn với Hệ thống Giám sát Bently Nevada 3500, cung cấp giám sát rung động và tình trạng máy móc theo thời gian thực để ngăn ngừa sự cố và tối đa hóa thời gian hoạt động.