Uyingizni eng so‘nggi ko‘p funksiyali elektronika yechimlari bilan o‘zgartiring, aqlli yoritishdan tortib ovozli boshqariladigan qurilmalargacha — bularning barchasi hayotingizni osonroq, xavfsizroq va yanada bog‘langan qilish uchun mo‘ljallangan.
SKU:AAI143-H53/K4A00
Yokogawa AAI143-H53/K4A00 | HART Protocol AI Module
Manufacturer: Yokogawa
Product No.: AAI143-H53/K4A00
Product Type: Analog Input Module
Product Origin: SG
Payment:T/T, Western Union
Weight: 300g
Shipping port: Xiamen
Warranty: 12 months
Ulashish
- Tez yetkazib berish
- 24/7 Qo'llab-quvvatlash
- Sifat nazorati
Tavsif
Yokogawa's AAI143-H53/K4A00 analog input module delivers high-performance signal acquisition. This reliable module integrates seamlessly into control systems for precise data collection.
Key Features & Benefits
- The AAI143-H53/K4A00 provides 16 fully isolated input channels, preventing ground loop issues.
- It accepts the standard 4 to 20 mA DC input signal from field transmitters.
- Integrated HART protocol digital communication allows for advanced device configuration and diagnostics.
- Each channel individually configures as a 2-wire or 4-wire transmitter via a simple setting pin.
- A fast 10 ms data update period enables real-time process monitoring and control.
Detailed Technical Specifications
- Brand: Yokogawa
- Model: AAI143-H53/K4A00
- Input Channels: 16 channels with individual isolation
- Input Signal Range: 4 to 20 mA DC
- Maximum Allowable Input: 24 mA
- Accuracy: ±16 µA for reliable measurement data
- Transmitter Power Supply: 19.0 V to 25.5 V DC (current limited to 25 mA)
- Withstanding Voltage: 1500 V AC for 1 minute between input and system
- Operating Temperature Range: -20 to 70 °C (-4 to 158 °F)
- Temperature Drift: ±16 µA per 10°C change
- Module Power Consumption: 230 mA (at 5V DC) and 540 mA (at 24V DC)
- Communication Interface: Includes a KS Cable Interface Adapter (ATK4A-00) for connecting to AEA4D terminal boards
- Unit Weight: Approximately 0.3 kilograms
Installation & Connection Guide
- Use the provided pressure clamp terminals or MIL connector for secure field wiring.
- The KS1 dedicated cable and K4A00 interface adapter ensure a proper connection to Yokogawa system racks.
- Configure each channel for 2-wire or 4-wire transmitter operation using the designated pins on the terminal board.
- Ensure the ambient temperature stays within the specified -20 to 70 °C range for optimal performance.
- Verify that the field device's loop current does not exceed the 24 mA maximum allowable input.
Packaging List
- 1 x Yokogawa AAI143-H53/K4A00 Analog Input Module
- 1 x KS Cable Interface Adapter (Model: ATK4A-00)
- All necessary documentation and mounting hardware
- We ship all orders via reliable carriers such as FedEx, UPS, or DHL.
Frequently Asked Questions (FAQ)
- What input signal does this Yokogawa module accept? The module is designed for standard 4 to 20 mA DC current loop inputs.
- How many devices can I connect to one module? The AAI143-H53/K4A00 gives you 16 independently isolated channels for connecting multiple transmitters.
- Does it support smart instrumentation communication? Yes, this module includes HART protocol support over the 4-20 mA signal for digital communication.
Qo'shimcha Texnik Tavsiflar
- Kulrang
Skalyar (V/f)
Vektor
AC quvvatli
Sotib olish bo‘yicha qo‘llanma
- Buyurtma berishdan oldin aniq model, qism raqami va texnik xususiyatlarni tasdiqlang.
- Joriy mashinalaringiz yoki boshqaruv tizimlaringiz bilan mosligini ta’minlang.
- Texnik yordam uchun sale@etowonauto.com manzili yoki +8617859788089 raqamiga murojaat qiling.
- Yetkazib berish variantlari, yetkazib berish muddati va jo‘natish talablarini ko‘rib chiqing.
- O‘rnatish paytida ishlab chiqaruvchi ko‘rsatmalariga va eng yaxshi amaliyotlarga rioya qiling.
Yuborish va Qaytarish
Omborda mavjud bo‘lgan mahsulotlar odatda shu ish kuni jo‘natiladi. Hozirda omborda mavjud bo‘lmagan mahsulotlar uchun jo‘natish vaqti mavjudlikka qarab o‘zgarishi mumkin. Xalqaro yetkazib berish mavjud bo‘lib, yetkazib berish xarajatlari manzil, vazn va tashuvchi tanloviga ko‘ra hisoblanadi.
Qaytishlar qabul qilingan kundan boshlab 30 kun ichida amalga oshiriladi, agar mahsulotlar ishlatilmagan va asl holatda bo‘lsa. Qaytish xarajatlari mijoz zimmasida bo‘ladi. Iltimos, har qanday mahsulotni qaytarishdan oldin qaytish ruxsatini olish uchun biz bilan bog‘laning.
Batafsil ma’lumot uchun iltimos, Yetkazib berish va Qaytarish Siyosatini ko‘rib chiqing.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Tez yetkazib berish
Dunyoda tez yetkazib berish uchun original sanoat avtomatlashtirish qismlari mavjud.
-
Oson qaytarish
Ishonchli sotuvdan keyingi himoya uchun 12 oylik kafolat bilan 30 kunlik qaytarish qo'llab-quvvatlashi.
-
24/7 qo‘llab-quvvatlash
Barqaror va samarali ish faoliyatini ta'minlash uchun javobgar professional yordam.
-
Haqiqiy va Asl
100% haqiqiy, ishonchli sanoat avtomatlashtirish ishlab chiqaruvchilaridan to‘g‘ridan-to‘g‘ri olingan.
Texnik va Xarid Qollanmasi
-
How to Select GE Fanuc 90-30 Spare Parts for Hot Rolling Mills?
This article provides a technical guide for selecting and managing GE Fanuc Series 90-30 PLC spare parts in meta...
-
How Does Bently Nevada 3500 Reduce Unplanned Turbine Trips?
This technical article analyzes the quantitative value of the Bently Nevada 3500 TSI system in thermal power shaft pr...
-
Dual Compliance Standards for Pharma Automation?
This article presents a quantified engineering methodology for explosion-proof PLC and DCS system design in GMP-certi...
-
How to Avoid Bulk Sourcing Risks for Power Plant Control Spares?
This guide presents field-validated strategies for bulk sourcing industrial control spares in power plants. It q...
-
What Are the Hidden Costs of Fake PLC and DCS Modules?
This guide presents data-driven verification protocols for imported industrial control spare parts, addressing the es...
-
Redundant PLC + DCS: 18.6% Fan Energy Savings?
This case study documents a full automation retrofit for a 300 TPD waste incineration plant. By integrating Emerson D...
