Uyingizni eng so‘nggi ko‘p funksiyali elektronika yechimlari bilan o‘zgartiring, aqlli yoritishdan tortib ovozli boshqariladigan qurilmalargacha — bularning barchasi hayotingizni osonroq, xavfsizroq va yanada bog‘langan qilish uchun mo‘ljallangan.
SKU:V18345-1010520001
Valve Positioner ABB V18345-1010520001
Manufacturer: ABB
Product No.: V18345-1010520001
Product Type: Valve Positioner Module
Product Origin: Sweden
Payment:T/T, Western Union
Weight: 1700g
Shipping port: Xiamen
Warranty: 12 months
Ulashish
- Tez yetkazib berish
- 24/7 Qo'llab-quvvatlash
- Sifat nazorati
Tavsif
Product Overview
ABB V18345-1010520001 is an electro-pneumatic valve positioner from the TZIDC series, built for precise control of pneumatic actuators on large rotary machinery. It converts a 4–20 mA control signal into a proportional air output, achieving 0.5% linearity and ±0.2% repeatability. The non-contact position sensor eliminates mechanical wear, delivering stable performance in turbine, compressor, and process valve applications.
Technical Configuration
Core Hardware
The positioner uses a piezoresistive pressure sensor for air output feedback and a Hall-effect sensor for valve stem position. The HART protocol enables remote calibration and diagnostics without breaking the air loop. A local LCD and push-buttons allow on-site setup, zero/span adjustment, and fault readout.
Technical Specifications
| Parameter | Value |
|---|---|
| Input Signal | 4–20 mA (HART) |
| Air Supply | 1.4–6.0 bar |
| Air Consumption | ≤0.03 kg/h (steady state) |
| Linearity | ±0.5% of span |
| Repeatability | ±0.2% of span |
| Operating Temperature | -40°C to +80°C |
| Protection Class | IP65 |
| Pneumatic Ports | 1/4" NPT |
| Electrical Entry | M20×1.5 |
| Housing Material | Aluminum, powder-coated |
| Weight | Approx. 1.7 kg |
Installation Guide
Mount the positioner rigidly on the actuator yoke and verify the feedback lever travels 0–100% without binding. Set the air supply to 1.4 bar minimum; below this, the output may not reach full stroke. Keep cable bend radius above 50 mm and route signal wiring away from VFD cables. For explosive atmospheres, confirm the certification label matches the zone classification before energizing.
Engineering Advantages
The TZIDC platform tolerates supply air contaminated with oil and dust, reducing downtime in dirty plant environments. The aluminum housing resists corrosion in coastal and chemical plants. HART diagnostics report valve signature data, helping maintenance teams plan repairs before a trip occurs. The unit drops into existing 4–20 mA loops without extra wiring.
Technical FAQs
Q1: How do I verify the positioner is calibrated correctly?
A1: Apply 4 mA and confirm the valve reaches 0% stroke; apply 20 mA and confirm 100%. Check the LCD readout matches the actual stem position within ±0.5%.
Q2: What does the 1010520001 suffix indicate?
A2: It defines the analog HART input, double-acting output, IP65 aluminum housing, and standard temperature range. Confirm against the nameplate before ordering spares.
Q3: Can this unit replace an older TZIDC positioner?
A3: Yes, it shares the same mounting footprint and 4–20 mA interface. Verify the pneumatic port size and cable entry match the existing installation.
Qo'shimcha Texnik Tavsiflar
- Kumush
Skalyar (V/f)
Vektor
AC quvvatli
Sotib olish bo‘yicha qo‘llanma
- Buyurtma berishdan oldin aniq model, qism raqami va texnik xususiyatlarni tasdiqlang.
- Joriy mashinalaringiz yoki boshqaruv tizimlaringiz bilan mosligini ta’minlang.
- Texnik yordam uchun sale@etowonauto.com manzili yoki +8617859788089 raqamiga murojaat qiling.
- Yetkazib berish variantlari, yetkazib berish muddati va jo‘natish talablarini ko‘rib chiqing.
- O‘rnatish paytida ishlab chiqaruvchi ko‘rsatmalariga va eng yaxshi amaliyotlarga rioya qiling.
Yuborish va Qaytarish
Omborda mavjud bo‘lgan mahsulotlar odatda shu ish kuni jo‘natiladi. Hozirda omborda mavjud bo‘lmagan mahsulotlar uchun jo‘natish vaqti mavjudlikka qarab o‘zgarishi mumkin. Xalqaro yetkazib berish mavjud bo‘lib, yetkazib berish xarajatlari manzil, vazn va tashuvchi tanloviga ko‘ra hisoblanadi.
Qaytishlar qabul qilingan kundan boshlab 30 kun ichida amalga oshiriladi, agar mahsulotlar ishlatilmagan va asl holatda bo‘lsa. Qaytish xarajatlari mijoz zimmasida bo‘ladi. Iltimos, har qanday mahsulotni qaytarishdan oldin qaytish ruxsatini olish uchun biz bilan bog‘laning.
Batafsil ma’lumot uchun iltimos, Yetkazib berish va Qaytarish Siyosatini ko‘rib chiqing.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Tez yetkazib berish
Dunyoda tez yetkazib berish uchun original sanoat avtomatlashtirish qismlari mavjud.
-
Oson qaytarish
Ishonchli sotuvdan keyingi himoya uchun 12 oylik kafolat bilan 30 kunlik qaytarish qo'llab-quvvatlashi.
-
24/7 qo‘llab-quvvatlash
Barqaror va samarali ish faoliyatini ta'minlash uchun javobgar professional yordam.
-
Haqiqiy va Asl
100% haqiqiy, ishonchli sanoat avtomatlashtirish ishlab chiqaruvchilaridan to‘g‘ridan-to‘g‘ri olingan.
Texnik va Xarid Qollanmasi
-
When Should You Replace a Yokogawa Analog IO Card?
This article breaks down Yokogawa analog AI/AO card calibration tolerances, drift aging benchmarks, and formal replac...
-
What Performance Gains Does S7-1500 Offer Over Legacy S7 PLCs?
Legacy Siemens S7-300 and S7-400 PLCs face spare-part shortages, rising failure rates and limited network capability,...
-
What Logic Changes Cut SIS False Trips by 94%?
This article examines practical logic modification and parameter tuning methods for ABB 800xA HI SIL3 safety ins...
-
Why Do FTE Redundancy Failovers Lock Up in DCS?
Honeywell FTE delivers sub-500 ms failover for Experion PKS, yet field records show 38% of outages stem from installa...
-
How Does the Bently Nevada 3500/42M Vibration Module Drift?
This technical guide examines the Bently Nevada 3500/42M vibration module within industrial automation architect...
-
What Causes IC694MDL Fault Codes in GE RX3i PLC Systems?
This guide explains GE RX3i IC694MDL discrete I/O fault codes, key electrical parameters, ESD and torque requirements...
