Uyingizni eng so‘nggi ko‘p funksiyali elektronika yechimlari bilan o‘zgartiring, aqlli yoritishdan tortib ovozli boshqariladigan qurilmalargacha — bularning barchasi hayotingizni osonroq, xavfsizroq va yanada bog‘langan qilish uchun mo‘ljallangan.
SKU:140DDO88500
Schneider Electric 140DDO88500 | 12-Channel Sink Output Module
Manufacturer: Schneider
Product No.: 140DDO88500
Product Type: Adaptor Module
Product Origin: FR
Payment:T/T, Western Union
Weight: 450g
Shipping port: Xiamen
Warranty: 12 months
Ulashish
- Tez yetkazib berish
- 24/7 Qo'llab-quvvatlash
- Sifat nazorati
Tavsif
Schneider Electric 140DDO88500 DC Output Module
The Schneider 140DDO88500 is a 12-point discrete output module for Modicon Quantum. It delivers 24-125V DC negative logic (sink) for industrial control applications.
Core Specifications
- Brand & Model: Schneider Electric 140DDO88500
- Series: Modicon Quantum
- Outputs: 12 discrete, 2 groups of 6
- Logic: Negative logic (sink)
- Voltage: 24…125V DC (19.2…156.2V limits)
Electrical Ratings
- Per Point: ≤0.75 A at 0…40°C
- Per Group: ≤3 A at 0…60°C
- Per Module: ≤6 A at 0…60°C
- Surge Current: 4 A for 1 ms
- Response Time: 1 ms (on/off)
- Switching Frequency: ≤50 Hz
Protection & Isolation
- Short-Circuit: Yes
- Internal Fuse: 4 A per group
- Overvoltage: Varistor per group
- Channel-Bus Isolation: 2500 Vrms DC
- Group-Group Isolation: 1200 Vrms DC
Diagnostics & Power
- Fault LED: Red (overcurrent)
- Status LEDs: 16 green (output status)
- Active LED: Green (bus communication)
- Bus Current: 375 mA (6 on), 650 mA (12 on)
- Power Dissipation: 1 W + (0.77 x all points on)
Environmental
- Operation: 0…60°C (32…140°F)
- Storage: -40…85°C (-40…185°F)
- Humidity: 95% non-condensing
- Altitude: ≤5000 m
- ESD Immunity: 4 kV contact, 8 kV air
Physical & Package
- Weight: 0.45 kg (0.99 lb)
- Package Weight: 515 g (18.2 oz)
- Package Dimensions: 31.2 x 4.5 x 16.3 cm
- Shipping: FedEx, UPS, DHL
Installation
- Power off before installation
- Insert into Quantum backplane
- Connect 24-125V DC supply
- Wire for sink (negative logic)
- Check LED status after power-up
FAQ
What is negative logic (sink)?
Output switches DC common to the load. Designed for sinking input devices.
Can I mix voltages?
No. All outputs share same external DC supply voltage.
What triggers red fault LED?
Overcurrent condition activates per-group protection.
Qo'shimcha Texnik Tavsiflar
- Kulrang
- Qora
Skalyar (V/f)
Vektor
AC quvvatli
Sotib olish bo‘yicha qo‘llanma
- Buyurtma berishdan oldin aniq model, qism raqami va texnik xususiyatlarni tasdiqlang.
- Joriy mashinalaringiz yoki boshqaruv tizimlaringiz bilan mosligini ta’minlang.
- Texnik yordam uchun sale@etowonauto.com manzili yoki +8617859788089 raqamiga murojaat qiling.
- Yetkazib berish variantlari, yetkazib berish muddati va jo‘natish talablarini ko‘rib chiqing.
- O‘rnatish paytida ishlab chiqaruvchi ko‘rsatmalariga va eng yaxshi amaliyotlarga rioya qiling.
Yuborish va Qaytarish
Omborda mavjud bo‘lgan mahsulotlar odatda shu ish kuni jo‘natiladi. Hozirda omborda mavjud bo‘lmagan mahsulotlar uchun jo‘natish vaqti mavjudlikka qarab o‘zgarishi mumkin. Xalqaro yetkazib berish mavjud bo‘lib, yetkazib berish xarajatlari manzil, vazn va tashuvchi tanloviga ko‘ra hisoblanadi.
Qaytishlar qabul qilingan kundan boshlab 30 kun ichida amalga oshiriladi, agar mahsulotlar ishlatilmagan va asl holatda bo‘lsa. Qaytish xarajatlari mijoz zimmasida bo‘ladi. Iltimos, har qanday mahsulotni qaytarishdan oldin qaytish ruxsatini olish uchun biz bilan bog‘laning.
Batafsil ma’lumot uchun iltimos, Yetkazib berish va Qaytarish Siyosatini ko‘rib chiqing.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Tez yetkazib berish
Dunyoda tez yetkazib berish uchun original sanoat avtomatlashtirish qismlari mavjud.
-
Oson qaytarish
Ishonchli sotuvdan keyingi himoya uchun 12 oylik kafolat bilan 30 kunlik qaytarish qo'llab-quvvatlashi.
-
24/7 qo‘llab-quvvatlash
Barqaror va samarali ish faoliyatini ta'minlash uchun javobgar professional yordam.
-
Haqiqiy va Asl
100% haqiqiy, ishonchli sanoat avtomatlashtirish ishlab chiqaruvchilaridan to‘g‘ridan-to‘g‘ri olingan.
Texnik va Xarid Qollanmasi
-
GE Fanuc dan Allen-Bradley ga Ishlab chiqarish To‘xtatmasdan Qanday Ko‘chirish Mumkin?
Ushbu maqola diskret ishlab chiqarish uchun GE Fanuc dan Allen-Bradley PLClarga ma'lumotlarga asoslangan migratsiya q...
-
Bently Nevada toʻplamlari markazdan qochma uskunalarning ish vaqtini qanday qisqartiradi?
Ushbu maqola Bently Nevada turnkey to‘plamlari markazdan qochma kompressorlar va ventilyatorlar uchun rejalashtirilma...
-
Masofadan Texnik Xizmat Fabrika Avtomatizatsiyasi Xarajatlarini Kamaytirishi Mumkinmi?
Ishlab chiqarish korxonalari an'anaviy joyida PLC texnik xizmatiga millionlab mablag‘ yo‘qotadi. Ushbu maqolada maydo...
-
Favqulodda Import Qilingan Zaxira Qismlar Rejalashtirilmagan Zavod To‘xtashlarini To‘xtata Oladimi?
Rejalashtirilmagan boshqaruv tizimi nosozliklari sanoat korxonalariga soatiga 500 000 dollargacha zarar yetkazadi, am...
-
Hamkorlikdagi DCS yuk javob kechikishlarini 0,4 soniyadan pastga qisqartira oladimi?
Ushbu maqola issiqlik elektr stantsiyalarida ko‘p birlikli hamkorlik boshqaruvi uchun ierarxik DCS arxitekturasini ta...
-
PLC kabinet issiqdan qanday qilib nosozlikni to'xtatish mumkin?
Ushbu maqola boshqaruv shkaflaridagi yashirin issiqlik avtomatlashtirishdagi tasodifiy nosozliklarning 68% sababchisi...
