Uyingizni eng so‘nggi ko‘p funksiyali elektronika yechimlari bilan o‘zgartiring, aqlli yoritishdan tortib ovozli boshqariladigan qurilmalargacha — bularning barchasi hayotingizni osonroq, xavfsizroq va yanada bog‘langan qilish uchun mo‘ljallangan.
SKU:IS200EPSMG2A
IS200EPSMG2A Power Supply | GE EX2100 Regulator Control
Manufacturer: General Electric
Product No.: IS200EPSMG2A
Product Type: Option Board
Product Origin: USA
Payment:T/T, Western Union
Weight: 900g
Shipping port: Xiamen
Warranty: 12 months
Ulashish
- Tez yetkazib berish
- 24/7 Qo'llab-quvvatlash
- Sifat nazorati
Tavsif
Product Overview
The GE IS200EPSMG2A Exciter Power Supply Module delivers reliable DC power for EX2100 regulator control systems. This module converts DC link bus voltage into the multiple outputs required for turbine excitation control. It pairs with the IS200EPSDG_A daughter board and supports simplex or redundant regulator configurations.
Core Functionality
The IS200EPSMG2A integrates a buck regulator and a push-pull inverter. The buck regulator converts input voltage to a 50Vdc intermediate stage. The push-pull inverter then generates the required multiple output voltages with high-voltage isolation via the internal transformer. The EPSD daughter board modifies the power input path to accept higher voltages and provides fuse protection between the DC link and buck regulator.
Technical Specifications
| Parameter | Value |
| Part Number | IS200EPSMG2A |
| Manufacturer | General Electric |
| Series | EX2100 |
| Product Type | Exciter Power Supply Module |
| Output Voltages | +5 Vdc, ±15 Vdc, +24 Vdc |
| Contact Wetting Supply | Isolated +70 Vdc |
| IGBT Gate Supply | Isolated 20 Vac |
| Ground Detector Supply | ±55 Vdc |
| Dimensions (H x W) | 15.9 x 17.8 cm |
| Weight | 0.9 kg (2 lbs) |
| Operating Temperature | -30°C to +65°C |
| Functional Revision | A |
| Reference Manual | GEI-100462A / GEH-6632 |
| Country of Origin | United States |
Installation Guide
Mount the IS200EPSMG2A in the IS200ERBPH_A Exciter Regulator Backplane (ERBP) for simplex systems. For redundant configurations, install one in ERBP (M1) and a second in IS200ERRBH_A (ERRB, M2/C). Ensure the EPSD daughter board is properly seated before insertion. Secure the module with the backplane connectors. Verify input voltage from the DC link meets specification. Route output cables to terminal boards and external modules per GEI-100462A guidelines.
Engineering Advantages
The IS200EPSMG2A delivers isolated +70Vdc for contact wetting, ensuring reliable switching of field contacts. The isolated 20Vac supply powers IGBT gates with robust isolation. ±55Vdc supports ground detector circuits on option cards. The EPSD board increases creepage and clearance distances for higher voltage acceptance. This module supports both simplex and redundant EX2100 regulator architectures, providing flexibility for system design.
Technical FAQs
Q1: What is the difference between EPSMG1 and EPSMG2?
A1: EPSMG1 powers EX2100 excitation control (M1, M2, C controllers). EPSMG2 powers EX2100 regulator control. EPSMG2 includes the EPSD daughter board and accepts higher input voltages.
Q2: Is the IS200EPSMG2A backward compatible with non-A revisions?
A2: No. The "A" revision indicates functional changes. This model is not backward compatible with earlier IS200EPSMG2 versions.
Q3: What external modules receive ±24Vdc from this supply?
A3: The ±24Vdc (P24B/N24B) powers fans, relays, and the DC feedback board in the regulator control system.
Qo'shimcha Texnik Tavsiflar
- Yashil
Skalyar (V/f)
Vektor
AC quvvatli
Sotib olish bo‘yicha qo‘llanma
- Buyurtma berishdan oldin aniq model, qism raqami va texnik xususiyatlarni tasdiqlang.
- Joriy mashinalaringiz yoki boshqaruv tizimlaringiz bilan mosligini ta’minlang.
- Texnik yordam uchun sale@etowonauto.com manzili yoki +8617859788089 raqamiga murojaat qiling.
- Yetkazib berish variantlari, yetkazib berish muddati va jo‘natish talablarini ko‘rib chiqing.
- O‘rnatish paytida ishlab chiqaruvchi ko‘rsatmalariga va eng yaxshi amaliyotlarga rioya qiling.
Yuborish va Qaytarish
Omborda mavjud bo‘lgan mahsulotlar odatda shu ish kuni jo‘natiladi. Hozirda omborda mavjud bo‘lmagan mahsulotlar uchun jo‘natish vaqti mavjudlikka qarab o‘zgarishi mumkin. Xalqaro yetkazib berish mavjud bo‘lib, yetkazib berish xarajatlari manzil, vazn va tashuvchi tanloviga ko‘ra hisoblanadi.
Qaytishlar qabul qilingan kundan boshlab 30 kun ichida amalga oshiriladi, agar mahsulotlar ishlatilmagan va asl holatda bo‘lsa. Qaytish xarajatlari mijoz zimmasida bo‘ladi. Iltimos, har qanday mahsulotni qaytarishdan oldin qaytish ruxsatini olish uchun biz bilan bog‘laning.
Batafsil ma’lumot uchun iltimos, Yetkazib berish va Qaytarish Siyosatini ko‘rib chiqing.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Tez yetkazib berish
Dunyoda tez yetkazib berish uchun original sanoat avtomatlashtirish qismlari mavjud.
-
Oson qaytarish
Ishonchli sotuvdan keyingi himoya uchun 12 oylik kafolat bilan 30 kunlik qaytarish qo'llab-quvvatlashi.
-
24/7 qo‘llab-quvvatlash
Barqaror va samarali ish faoliyatini ta'minlash uchun javobgar professional yordam.
-
Haqiqiy va Asl
100% haqiqiy, ishonchli sanoat avtomatlashtirish ishlab chiqaruvchilaridan to‘g‘ridan-to‘g‘ri olingan.
Texnik va Xarid Qollanmasi
-
Can Emerson DeltaV DCS Cards Optimize Chemical Safety Loops?
This technical article examines how Emerson DeltaV DCS card upgrades address legacy control limitations in chemical p...
-
Is Partial CNC Board Replacement Better Than a Full System Upgrade?
This technical article examines the dominance of GE Fanuc CNC hardware in heavy-duty automation, supported by field d...
-
Can Genuine PLC Modules Cut DCS Downtime 60%?
This article examines how genuine Allen-Bradley PLC module replacement strategies directly reduce unplanned DCS downt...
-
Is Your GE Fanuc PLC Talking to ABB DCS?
This article reveals how cross-system data silos between GE Fanuc PLC and ABB DCS cause 8–15% production losses in pr...
-
Can Integrated PLC-DCS-TSI Fix Data Silos?
Most industrial digital twins remain static visualization tools because discrete control, process automation, and con...
-
How to Cut Power Plant Outages with ABB and GE Fanuc Retrofits?
This technical article outlines a data-driven approach to modernizing power plant control systems using a hybrid ABB ...
