Delta VFD485VP43AFTHA | 3-Phase 460V 91A Drive
Manufacturer: Delta
Product No.: VFD485VP43AFTHA
Product Type: AC Drive
Product Origin: CN
Payment:T/T, Western Union
Weight: 8000g
Shipping port: Xiamen
Warranty: 12 months
Ulashish
- Tez yetkazib berish
- 24/7 Qo'llab-quvvatlash
- Sifat nazorati
Tavsif
Product Overview
The Delta VFD485VP43AFTHA is a high-capacity Variable Frequency Drive (VFD) engineered for heavy-duty industrial fluid control. With a robust output of 45kW (60HP), this drive excels in managing large-scale HVAC systems, water treatment pumps, and industrial cooling towers. This specific "THA" variant incorporates enhanced thermal management and an integrated DC reactor to suppress harmonic distortion, ensuring compliance with strict power quality standards. Its advanced Sensorless Vector Control (SVC) provides the perfect balance between high starting torque and energy-efficient cruise speeds.
Technical Configuration
Model Specification Logic
- Power Rating (485): Delivers a rated output current of 91 Amps, supporting motors up to 45kW (60HP).
- Series (VP): Specialized for variable torque loads, offering a multi-pump control mode and fire mode for emergency fan operation.
- Voltage Class (43): 460V 3-Phase input (compatible with 380V–480V ±10% utility grids).
- Filter & Reactor (AF): Includes a built-in EMC filter (Class A) and an internal DC reactor to reduce THDi (Total Harmonic Distortion).
- Frame Configuration (THA): Features a reinforced chassis with an independent cooling duct design to isolate power components from dust.
Technical Specifications
| Parameter | Data Value Details |
|---|---|
| Rated Output Current | 91 A (Normal Duty) |
| Applicable Motor Output | 45 kW / 60 HP |
| Input Current | 86 A (3-Phase AC) |
| Braking Torque | Approx. 20% (Standard); up to 125% with external unit |
| Starting Torque | 150% at 0.5Hz (SVC mode) |
| Frequency Stability | Digital: ±0.01%; Analog: ±0.2% |
| Efficiency | ≥ 97.5% at rated load |
| Enclosure Rating | IP20 (Standard) / NEMA 1 Optional |
Installation & Maintenance Guide
High-Power Engineering Standards
Power Quality: The integrated DC reactor in the VFD485VP43AFTHA significantly reduces harmonics. No additional line reactor is required unless the power source impedance is less than 3%. This reduces both installation footprint and overall system cost.
Cooling Architecture: This model utilizes an isolated cooling duct. When mounting in a cabinet, ensure the exhaust air is vented directly out of the enclosure to prevent internal heat buildup. The drive’s fans are field-replaceable to ensure long-term uptime.
Torque Terminal Torque: For the 91A output terminals, use M6 or M8 ring terminals with a tightening torque of 4.0-5.0 N-m to prevent hot spots caused by loose electrical connections.
Engineering Advantages
The VFD485VP43AFTHA features an Advanced Multi-Pump Control logic, capable of managing up to 4 pumps simultaneously (1 master fixed speed + 3 auxiliary). It includes a built-in RS-485 interface supporting Modbus RTU/ASCII with speeds up to 38.4kbps. Its 4-layer conformal coating protects the 45kW power bridge and control logic from moisture and chemical vapors, making it suitable for wastewater treatment facilities and chemical processing plants.
Technical FAQs
Q1: What is the maximum carrier frequency for this 45kW model?
A1: The carrier frequency can be set between 2kHz and 10kHz. For a 45kW drive, 4kHz is the recommended default to balance switching losses and acoustic motor noise.
Q2: Can I run this drive on a single-phase supply for testing?
A2: No. High-power VP series drives require a balanced 3-phase input to prevent phase-loss protection trips and potential damage to the input rectifier bridge.
Q3: How does the "Fire Mode" work in this drive?
A3: When activated via a digital input, the VFD ignores non-critical alarms and runs at a preset frequency to ensure smoke extraction or water pressure is maintained during emergency events.
Qo'shimcha Texnik Tavsiflar
- Qora
- Kulrang
Skalyar (V/f)
Vektor
AC quvvatli
Sotib olish bo‘yicha qo‘llanma
- Buyurtma berishdan oldin aniq model, qism raqami va texnik xususiyatlarni tasdiqlang.
- Joriy mashinalaringiz yoki boshqaruv tizimlaringiz bilan mosligini ta’minlang.
- Texnik yordam uchun sale@etowonauto.com manzili yoki +8617859788089 raqamiga murojaat qiling.
- Yetkazib berish variantlari, yetkazib berish muddati va jo‘natish talablarini ko‘rib chiqing.
- O‘rnatish paytida ishlab chiqaruvchi ko‘rsatmalariga va eng yaxshi amaliyotlarga rioya qiling.
Yuborish va Qaytarish
Omborda mavjud bo‘lgan mahsulotlar odatda shu ish kuni jo‘natiladi. Hozirda omborda mavjud bo‘lmagan mahsulotlar uchun jo‘natish vaqti mavjudlikka qarab o‘zgarishi mumkin. Xalqaro yetkazib berish mavjud bo‘lib, yetkazib berish xarajatlari manzil, vazn va tashuvchi tanloviga ko‘ra hisoblanadi.
Qaytishlar qabul qilingan kundan boshlab 30 kun ichida amalga oshiriladi, agar mahsulotlar ishlatilmagan va asl holatda bo‘lsa. Qaytish xarajatlari mijoz zimmasida bo‘ladi. Iltimos, har qanday mahsulotni qaytarishdan oldin qaytish ruxsatini olish uchun biz bilan bog‘laning.
Batafsil ma’lumot uchun iltimos, Yetkazib berish va Qaytarish Siyosatini ko‘rib chiqing.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Tez yetkazib berish
Dunyoda tez yetkazib berish uchun original sanoat avtomatlashtirish qismlari mavjud.
-
Oson qaytarish
Ishonchli sotuvdan keyingi himoya uchun 12 oylik kafolat bilan 30 kunlik qaytarish qo'llab-quvvatlashi.
-
24/7 qo‘llab-quvvatlash
Barqaror va samarali ish faoliyatini ta'minlash uchun javobgar professional yordam.
-
Haqiqiy va Asl
100% haqiqiy, ishonchli sanoat avtomatlashtirish ishlab chiqaruvchilaridan to‘g‘ridan-to‘g‘ri olingan.
Texnik va Xarid Qollanmasi
-
Nima uchun PLC signal aralashuvi 61% to‘xtatishlarga sabab bo‘ladi?
Og‘ir yuk liniyalari EMI va yuk zarbalari tufayli yig‘ish liniyalariga nisbatan 3,2 barobar ko‘proq boshqaruv xatolar...
-
Bulut Avtomatizatsiyasining Tasdiqlangan ROIsi Nima?
Global ishlab chiqaruvchilar tarqalgan joylar va cheklangan texnik xizmat ko‘rsatish xodimlariga duch kelishadi. Ushb...
-
Sizning Kichik va O‘rta Biznes Jarayonlaringiz Zavodi Sanoat Avtomatizatsiyasi uchun Ortikcha To‘layaptimi?
Ushbu maqola kichik va o‘rta korxonalar jarayon fabrikalari uchun ortiqcha xarajat qilmasdan to‘g‘ri o‘lchamdagi DCS ...
-
Nima uchun CPU zaxirasi bo‘lishiga qaramay, 420 000 dollarlik to‘xtash yuz berdi?
Ushbu maqola 15 yillik maydonda sinovdan o'tgan dalillarni taqdim etadi, ular qisman DCS zaxirasi mavjud bo‘lsa ham, ...
-
How Does Emerson Edge Control Cut Cloud Dependency by 60%?
Emerson Edge Control Terminal processes OT data on-site, reducing latency to under 20ms and filtering 60% redundant d...
-
Low-Cost Brownfield Automation: Zero Downtime Possible?
This article shows how brownfield plants modernize legacy PLC and DCS systems using protocol gateways and edge termin...