Uyingizni eng so‘nggi ko‘p funksiyali elektronika yechimlari bilan o‘zgartiring, aqlli yoritishdan tortib ovozli boshqariladigan qurilmalargacha — bularning barchasi hayotingizni osonroq, xavfsizroq va yanada bog‘langan qilish uchun mo‘ljallangan.
SKU:VFD220VP43AFTDA-VFTDA
Delta VFD220VP43AFTDA-VFTDA | High Performance VFD
Manufacturer: Delta
Product No.: VFD220VP43AFTDA-VFTDA
Product Type: AC Drive
Product Origin: CN
Payment:T/T, Western Union
Weight: 8000g
Shipping port: Xiamen
Warranty: 12 months
Ulashish
- Tez yetkazib berish
- 24/7 Qo'llab-quvvatlash
- Sifat nazorati
Tavsif
Product Overview
The Delta VFD220VP43AFTDA-VFTDA is a premier Variable Frequency Drive (VFD) from the high-performance VP series, specifically optimized for fluid machinery such as fans, pumps, and blowers. This 22kW (30HP) drive integrates advanced sensorless vector control (SVC) to deliver precise torque management and energy efficiency. Engineered for industrial 460V three-phase systems, it features a robust hardware architecture that ensures stable operation under fluctuating loads.
Technical Configuration
Model Identification & Logic
- Power Rating (220): Indicates a rated output capacity of 22kW (30 Horsepower), suitable for medium-to-large motor control.
- Series (VP): Specialized series for Fan and Pump applications, featuring enhanced PID control and energy-saving modes.
- Voltage Class (43): Designed for 460V 3-Phase input power systems (operates within 380V–480V range).
- Integrated Filter (AF): Built-in RFI/EMC filter to minimize electromagnetic interference in sensitive industrial environments.
- Hardware Design (TDA): Represents the specific frame size and terminal layout configuration for optimized heat dissipation.
Technical Specifications
| Parameter | Technical Data Details |
|---|---|
| Rated Output Capacity | 34 kVA |
| Rated Output Current | 45 A (Continuous) |
| Maximum Output Voltage | 3-Phase proportional to input (Max 480V) |
| Output Frequency Range | 0.1 to 600.00 Hz |
| Overload Capacity | 120% of rated current for 60 seconds |
| Carrier Frequency | 2 kHz to 15 kHz (Auto-adjusting based on load) |
| Control Method | SVPWM, Sensorless Vector Control (SVC) |
| Protection Level | IP20 / UL Type 1 |
Installation & Engineering Guide
Operational Best Practices
Heat Dissipation: Maintain a minimum clearance of 50mm on the sides and 120mm above/below the drive. The VFD220VP43AFTDA utilizes forced air cooling; ensure the cabinet ambient temperature stays below 50°C to prevent thermal derating.
Wiring Integrity: Use shielded cables for the motor leads to reduce EMI. The maximum recommended cable length without an output reactor is 30 meters. Ensure the ground terminal (E) is connected to a dedicated industrial ground point.
PID Tuning: Utilize the built-in PID feedback loops for constant pressure pump control. Set the sleep/wake-up frequency parameters to maximize energy savings during low-demand periods.
Engineering Advantages
The VFD220VP43AFTDA-VFTDA distinguishes itself through its intelligent energy-saving algorithms, which automatically reduce motor voltage during low-load conditions to decrease power consumption. It features a high-speed communication interface (MODBUS) as standard, allowing seamless integration into PLC-based factory automation networks. The drive's circuit boards are conformal coated to provide resistance against dust and corrosive gases, significantly extending the service life in harsh industrial atmospheres.
Technical FAQs
Q1: Does this model include a built-in braking resistor?
A1: No, for 22kW models, an external braking unit (BUE series) and resistors are required if the application involves high-inertia loads or rapid deceleration cycles.
Q2: Can I use this drive for a constant torque application like a conveyor?
A2: While optimized for fans and pumps (variable torque), it can handle constant torque loads if the current demand does not exceed 45A. However, a VFD-C2000 series might be more appropriate for heavy-start torque needs.
Q3: What is the significance of the "AF" in the model code?
A3: It indicates a built-in EMC filter that complies with EN61800-3 standards, reducing high-frequency noise that could otherwise interfere with nearby sensors or controllers.
Qo'shimcha Texnik Tavsiflar
- Qora
- Kulrang
Skalyar (V/f)
Vektor
AC quvvatli
Sotib olish bo‘yicha qo‘llanma
- Buyurtma berishdan oldin aniq model, qism raqami va texnik xususiyatlarni tasdiqlang.
- Joriy mashinalaringiz yoki boshqaruv tizimlaringiz bilan mosligini ta’minlang.
- Texnik yordam uchun sale@etowonauto.com manzili yoki +8617859788089 raqamiga murojaat qiling.
- Yetkazib berish variantlari, yetkazib berish muddati va jo‘natish talablarini ko‘rib chiqing.
- O‘rnatish paytida ishlab chiqaruvchi ko‘rsatmalariga va eng yaxshi amaliyotlarga rioya qiling.
Yuborish va Qaytarish
Omborda mavjud bo‘lgan mahsulotlar odatda shu ish kuni jo‘natiladi. Hozirda omborda mavjud bo‘lmagan mahsulotlar uchun jo‘natish vaqti mavjudlikka qarab o‘zgarishi mumkin. Xalqaro yetkazib berish mavjud bo‘lib, yetkazib berish xarajatlari manzil, vazn va tashuvchi tanloviga ko‘ra hisoblanadi.
Qaytishlar qabul qilingan kundan boshlab 30 kun ichida amalga oshiriladi, agar mahsulotlar ishlatilmagan va asl holatda bo‘lsa. Qaytish xarajatlari mijoz zimmasida bo‘ladi. Iltimos, har qanday mahsulotni qaytarishdan oldin qaytish ruxsatini olish uchun biz bilan bog‘laning.
Batafsil ma’lumot uchun iltimos, Yetkazib berish va Qaytarish Siyosatini ko‘rib chiqing.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Tez yetkazib berish
Dunyoda tez yetkazib berish uchun original sanoat avtomatlashtirish qismlari mavjud.
-
Oson qaytarish
Ishonchli sotuvdan keyingi himoya uchun 12 oylik kafolat bilan 30 kunlik qaytarish qo'llab-quvvatlashi.
-
24/7 qo‘llab-quvvatlash
Barqaror va samarali ish faoliyatini ta'minlash uchun javobgar professional yordam.
-
Haqiqiy va Asl
100% haqiqiy, ishonchli sanoat avtomatlashtirish ishlab chiqaruvchilaridan to‘g‘ridan-to‘g‘ri olingan.
Texnik va Xarid Qollanmasi
-
Nima uchun PLC signal aralashuvi 61% to‘xtatishlarga sabab bo‘ladi?
Og‘ir yuk liniyalari EMI va yuk zarbalari tufayli yig‘ish liniyalariga nisbatan 3,2 barobar ko‘proq boshqaruv xatolar...
-
Bulut Avtomatizatsiyasining Tasdiqlangan ROIsi Nima?
Global ishlab chiqaruvchilar tarqalgan joylar va cheklangan texnik xizmat ko‘rsatish xodimlariga duch kelishadi. Ushb...
-
Sizning Kichik va O‘rta Biznes Jarayonlaringiz Zavodi Sanoat Avtomatizatsiyasi uchun Ortikcha To‘layaptimi?
Ushbu maqola kichik va o‘rta korxonalar jarayon fabrikalari uchun ortiqcha xarajat qilmasdan to‘g‘ri o‘lchamdagi DCS ...
-
Nima uchun CPU zaxirasi bo‘lishiga qaramay, 420 000 dollarlik to‘xtash yuz berdi?
Ushbu maqola 15 yillik maydonda sinovdan o'tgan dalillarni taqdim etadi, ular qisman DCS zaxirasi mavjud bo‘lsa ham, ...
-
How Does Emerson Edge Control Cut Cloud Dependency by 60%?
Emerson Edge Control Terminal processes OT data on-site, reducing latency to under 20ms and filtering 60% redundant d...
-
Low-Cost Brownfield Automation: Zero Downtime Possible?
This article shows how brownfield plants modernize legacy PLC and DCS systems using protocol gateways and edge termin...
