Uyingizni eng so‘nggi ko‘p funksiyali elektronika yechimlari bilan o‘zgartiring, aqlli yoritishdan tortib ovozli boshqariladigan qurilmalargacha — bularning barchasi hayotingizni osonroq, xavfsizroq va yanada bog‘langan qilish uchun mo‘ljallangan.
SKU:VFD180VP43AFTDA-VFTDA
Delta VFD180VP43AFTDA-VFTDA Variable Frequency Drive
Manufacturer: Delta
Product No.: VFD180VP43AFTDA-VFTDA
Product Type: AC Drive
Product Origin: CN
Payment:T/T, Western Union
Weight: 8000g
Shipping port: Xiamen
Warranty: 12 months
Ulashish
- Tez yetkazib berish
- 24/7 Qo'llab-quvvatlash
- Sifat nazorati
Tavsif
Product Overview
The Delta VFD180VP43AFTDA-VFTDA is a premier member of the VFD-VP series, specifically engineered for fan and pump applications. This 18.5kW (25HP) Variable Frequency Drive (VFD) optimizes energy consumption and enhances system reliability in HVAC, water treatment, and industrial fluid control. By utilizing advanced motor control algorithms, it ensures smooth pressure and flow management while significantly reducing mechanical wear on the system.
Technical Specifications
| Parameter | Value / Specification |
|---|---|
| Rated Output Power | 18.5 kW (25 HP) |
| Input Voltage Range | 3-Phase 380V - 480V AC (50/60Hz) |
| Rated Output Current | 38.0 A |
| Output Frequency Range | 0.1 to 599.0 Hz |
| Overload Capacity | 120% of rated current for 60 seconds |
| Control Method | V/F, SVC, PM Sensorless, FOC Sensorless |
| Built-in Filter | Standard EMC Filter (C3 Level) |
| Enclosure Rating | IP20 / UL Type 1 |
Core Functional Advantages
Advanced Energy Saving
The VFD180VP43AFTDA achieves up to 98% efficiency at rated load. Its specialized "Pump Sleep Mode" detects low-flow conditions and automatically stops the motor to conserve power, restarting instantly when system demand increases.
Multi-Pump Control Logic
This drive excels in parallel pump systems. It can control up to 4 pumps simultaneously using fixed-amount or fixed-time circulation modes. This ensures equalized runtime across all units, preventing premature failure of a single motor.
Intelligent Protection Suite
Integrated hardware safeguards include over-voltage (800V DC trip), under-voltage, over-current, and motor thermal protection (I²t). The circuit boards are treated with a conformal coating to resist humidity and dust in industrial environments.
Installation & Wiring Guidelines
For optimal performance, follow these engineering standards during commissioning:
- Wiring: Use shielded power cables for motor connections to minimize Electromagnetic Interference (EMI). Ensure the ground wire is at least 10mm² for safety.
- Cooling: Maintain a minimum clearance of 50mm on the sides and 150mm at the top/bottom of the drive to allow for adequate airflow.
- Control Terminals: Digital inputs (S1-S6) are multi-functional; configure them for Start/Stop, Forward/Reverse, or Multi-step speed control via the Delta keypad.
Technical FAQs
Q1: Does this model support PM motors?
A1: Yes, the VFD-VP series supports both traditional Induction Motors and high-efficiency Permanent Magnet Motors using sensorless vector control.
Q2: Can I use this drive for heavy-duty conveyor applications?
A2: While it can run a conveyor, this "VP" model is optimized for variable torque loads (Fans/Pumps). For constant torque, heavy-duty applications, we recommend the Delta VFD-C2000 series.
Q3: How do I connect the drive to a PLC system?
A3: The drive comes standard with RS-485 Modbus communication. It can also be expanded with optional cards for PROFIBUS DP, DeviceNet, or EtherNet/IP for seamless industrial automation integration.
Qo'shimcha Texnik Tavsiflar
- Qora
- Kulrang
Skalyar (V/f)
Vektor
AC quvvatli
Sotib olish bo‘yicha qo‘llanma
- Buyurtma berishdan oldin aniq model, qism raqami va texnik xususiyatlarni tasdiqlang.
- Joriy mashinalaringiz yoki boshqaruv tizimlaringiz bilan mosligini ta’minlang.
- Texnik yordam uchun sale@etowonauto.com manzili yoki +8617859788089 raqamiga murojaat qiling.
- Yetkazib berish variantlari, yetkazib berish muddati va jo‘natish talablarini ko‘rib chiqing.
- O‘rnatish paytida ishlab chiqaruvchi ko‘rsatmalariga va eng yaxshi amaliyotlarga rioya qiling.
Yuborish va Qaytarish
Omborda mavjud bo‘lgan mahsulotlar odatda shu ish kuni jo‘natiladi. Hozirda omborda mavjud bo‘lmagan mahsulotlar uchun jo‘natish vaqti mavjudlikka qarab o‘zgarishi mumkin. Xalqaro yetkazib berish mavjud bo‘lib, yetkazib berish xarajatlari manzil, vazn va tashuvchi tanloviga ko‘ra hisoblanadi.
Qaytishlar qabul qilingan kundan boshlab 30 kun ichida amalga oshiriladi, agar mahsulotlar ishlatilmagan va asl holatda bo‘lsa. Qaytish xarajatlari mijoz zimmasida bo‘ladi. Iltimos, har qanday mahsulotni qaytarishdan oldin qaytish ruxsatini olish uchun biz bilan bog‘laning.
Batafsil ma’lumot uchun iltimos, Yetkazib berish va Qaytarish Siyosatini ko‘rib chiqing.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Tez yetkazib berish
Dunyoda tez yetkazib berish uchun original sanoat avtomatlashtirish qismlari mavjud.
-
Oson qaytarish
Ishonchli sotuvdan keyingi himoya uchun 12 oylik kafolat bilan 30 kunlik qaytarish qo'llab-quvvatlashi.
-
24/7 qo‘llab-quvvatlash
Barqaror va samarali ish faoliyatini ta'minlash uchun javobgar professional yordam.
-
Haqiqiy va Asl
100% haqiqiy, ishonchli sanoat avtomatlashtirish ishlab chiqaruvchilaridan to‘g‘ridan-to‘g‘ri olingan.
Texnik va Xarid Qollanmasi
-
Can a Bently Nevada TSI Retrofit Cut False Alarms 71.8%?
This technical guide examines the strategic approach to partial TSI system retrofits for Bently Nevada 3500 series ha...
-
Can Long-Term Vibration Trends Predict Rotating Equipment Fatigue?
Standard PLC and DCS systems often fail to detect progressive mechanical fatigue because they prioritize process vari...
-
How Do PLCs Turn Machine Data Into Proactive Risk Defense?
This article explores how Allen‑Bradley real‑time production monitoring mitigates hidden operational risks in disc...
-
Can Proper HMI Commissioning Really Cut Downtime by 54%?
This article examines the pivotal role of HMI visualization in industrial automation, drawing on field experience wit...
-
Can a Phased Retrofit Cut Your GE Upgrade Costs by Over 50%?
This article examines strategic approaches to modernizing legacy GE PLC and DCS systems in brown‑field industrial sit...
-
How does off-site monitoring cut fault diagnosis time by 79%?
This article examines how GE long-distance data transmission enables off-site centralized monitoring for geographi...
