Uyingizni eng so‘nggi ko‘p funksiyali elektronika yechimlari bilan o‘zgartiring, aqlli yoritishdan tortib ovozli boshqariladigan qurilmalargacha — bularning barchasi hayotingizni osonroq, xavfsizroq va yanada bog‘langan qilish uchun mo‘ljallangan.
SKU:VFD022EL21W
Delta VFD EL-W 2 Horsepower 230V Motor Drive VFD022EL21W
Manufacturer: Delta
Product No.: VFD022EL21W
Product Type: AC Drive
Product Origin: CN
Payment:T/T, Western Union
Weight: 1000g
Shipping port: Xiamen
Warranty: 12 months
Ulashish
- Tez yetkazib berish
- 24/7 Qo'llab-quvvatlash
- Sifat nazorati
Tavsif
Product Overview
The VFD022EL21W(-1) is an ultra-compact, cost-effective micro-type AC motor drive from Delta’s streamlined VFD EL-W Series. Engineered specifically to optimize space and reduce costs in low-horsepower applications, this 2 HP (2.2 kW) variable frequency inverter provides stable velocity modulation for standard automation equipment like commercial mixers, fans, pumps, and light-duty material conveyors. It operates efficiently on a standard 1-phase 230 V AC input line and delivers a steady 11 A output. Featuring a highly specialized shallow-depth housing and an incredibly lightweight structure weighing only 2.2 lbs (1.0 kg), it delivers exceptional power density for restricted panel layouts.
Core Technical Advantages
Optimized Shallow-Depth Housing
The specialized EL-W series features a modified physical geometry with a reduced depth profile of just 5.35 inches (with a total installation space envelope of 3.94 × 3.5 × 6.85 inches). This compact layout lets system builders mount the drive inside shallow electrical enclosures where standard inverters cannot fit.
High-Density Side-by-Side Mounting
The optimized thermal dissipation architecture allows high-density side-by-side configurations on standard DIN rails. This structural arrangement cuts cabinet space requirements dramatically while providing high power output from a single-phase supply line.
Efficient Scalar Performance
Supporting a maximum adjustable output frequency up to 400 Hz, the open-loop V/Hz (Scalar) control system ensures accurate torque compensation and smooth speed curves for standard induction motors and high-speed processing machinery.
Technical Specifications
| Parameter | Specification Details |
|---|---|
| Manufacturer | Delta Products (VFD EL-W Series) |
| Model Number | VFD022EL21W(-1) |
| Motor Power Rating | 2.0 HP / 2.2 kW |
| Rated Output Amps | 11 Amps |
| Nominal Input VAC | 230 Volts AC (Range: 200–240 V) |
| Input Phase | 1-Phase |
| Device Net Weight | 2.2 lbs (1.0 kg) |
| Enclosure Rating | IP20 |
| Dimensions (W × H × D) | 3.94 × 3.5 × 6.85 Inches |
Installation and Maintenance
Enclosure Thermal Layouts
The IP20 open-type chassis must sit within a clean, dry, well-ventilated cabinet environment free from oil mist, moisture, and conductive metal shavings. Keep a minimum vertical clearance of 50 mm above and below the module to allow heat from the cooling vents to escape properly.
Power Integration Rules
Terminate incoming single-phase mains wires exclusively to input terminals L1 and L2. Wire the motor leads directly to terminals U, V, and W. Never introduce utility AC lines to the U, V, W outputs, or the internal power semiconductor components will suffer irreversible catastrophic failure.
Braking Configuration
For operations involving rapid deceleration steps, fine-tune the internal deceleration parameters ($DEC$) to prevent regenerative energy from creating an overvoltage spike. Ensure proper line filtering is applied to maintain compliance with local industrial EMC guidelines.
Engineering Advantages
Onboard User Controls
The built-in human-machine interface includes a clear digital parameter screen and localized control buttons. This allows plant electricians to modify speed curves, monitor running amperage, and pull historical fault logs directly on the shop floor without secondary service computers.
Streamlined V/Hz Regulation
By optimizing high-demand open-loop scalar algorithms, this drive offers automatic torque boosting, multi-step operations, and integrated electronic thermal protection without the high cost overhead of advanced vector-drive systems.
Active Circuit Defense
Onboard firmware elements actively check for overcurrent, overvoltage, low input voltage, and ground leaks. If a fault is found, the inverter trips instantly to protect both the internal electronic components and the motor winding insulation.
Technical FAQs
Q1: What is the main design difference between the standard VFD-EL series and this EL-W variant?
A1: The EL-W variant features a modified structural layout that optimizes installation dimensions for shallower enclosures. It focuses on core open-loop application requirements, offering a lighter weight of 2.2 lbs and a lower cost framework for highly competitive automation tasks.
Q2: Can this single-phase drive be run on a 3-phase AC input supply?
A2: No. This unit is strictly rated for 1-phase 230 V AC input line connections. Attempting to run it on 3-phase lines can lead to erratic voltage monitoring behavior or unbalanced thermal stress on the input bridge rectifier circuits.
Q3: How do I avoid acceleration stall faults when running heavy conveyor loads?
A3: If the drive trips on overcurrent or struggles at startup, increase the acceleration time parameter ($ACC$) to give the drive more time to ramp up, or fine-tune the manual torque boost configuration to supply more voltage at low speeds.
Qo'shimcha Texnik Tavsiflar
- Qora
- Kulrang
Skalyar (V/f)
Vektor
AC quvvatli
Sotib olish bo‘yicha qo‘llanma
- Buyurtma berishdan oldin aniq model, qism raqami va texnik xususiyatlarni tasdiqlang.
- Joriy mashinalaringiz yoki boshqaruv tizimlaringiz bilan mosligini ta’minlang.
- Texnik yordam uchun sale@etowonauto.com manzili yoki +8617859788089 raqamiga murojaat qiling.
- Yetkazib berish variantlari, yetkazib berish muddati va jo‘natish talablarini ko‘rib chiqing.
- O‘rnatish paytida ishlab chiqaruvchi ko‘rsatmalariga va eng yaxshi amaliyotlarga rioya qiling.
Yuborish va Qaytarish
Omborda mavjud bo‘lgan mahsulotlar odatda shu ish kuni jo‘natiladi. Hozirda omborda mavjud bo‘lmagan mahsulotlar uchun jo‘natish vaqti mavjudlikka qarab o‘zgarishi mumkin. Xalqaro yetkazib berish mavjud bo‘lib, yetkazib berish xarajatlari manzil, vazn va tashuvchi tanloviga ko‘ra hisoblanadi.
Qaytishlar qabul qilingan kundan boshlab 30 kun ichida amalga oshiriladi, agar mahsulotlar ishlatilmagan va asl holatda bo‘lsa. Qaytish xarajatlari mijoz zimmasida bo‘ladi. Iltimos, har qanday mahsulotni qaytarishdan oldin qaytish ruxsatini olish uchun biz bilan bog‘laning.
Batafsil ma’lumot uchun iltimos, Yetkazib berish va Qaytarish Siyosatini ko‘rib chiqing.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Tez yetkazib berish
Dunyoda tez yetkazib berish uchun original sanoat avtomatlashtirish qismlari mavjud.
-
Oson qaytarish
Ishonchli sotuvdan keyingi himoya uchun 12 oylik kafolat bilan 30 kunlik qaytarish qo'llab-quvvatlashi.
-
24/7 qo‘llab-quvvatlash
Barqaror va samarali ish faoliyatini ta'minlash uchun javobgar professional yordam.
-
Haqiqiy va Asl
100% haqiqiy, ishonchli sanoat avtomatlashtirish ishlab chiqaruvchilaridan to‘g‘ridan-to‘g‘ri olingan.
Texnik va Xarid Qollanmasi
-
Nima uchun PLC signal aralashuvi 61% to‘xtatishlarga sabab bo‘ladi?
Og‘ir yuk liniyalari EMI va yuk zarbalari tufayli yig‘ish liniyalariga nisbatan 3,2 barobar ko‘proq boshqaruv xatolar...
-
Bulut Avtomatizatsiyasining Tasdiqlangan ROIsi Nima?
Global ishlab chiqaruvchilar tarqalgan joylar va cheklangan texnik xizmat ko‘rsatish xodimlariga duch kelishadi. Ushb...
-
Sizning Kichik va O‘rta Biznes Jarayonlaringiz Zavodi Sanoat Avtomatizatsiyasi uchun Ortikcha To‘layaptimi?
Ushbu maqola kichik va o‘rta korxonalar jarayon fabrikalari uchun ortiqcha xarajat qilmasdan to‘g‘ri o‘lchamdagi DCS ...
-
Nima uchun CPU zaxirasi bo‘lishiga qaramay, 420 000 dollarlik to‘xtash yuz berdi?
Ushbu maqola 15 yillik maydonda sinovdan o'tgan dalillarni taqdim etadi, ular qisman DCS zaxirasi mavjud bo‘lsa ham, ...
-
How Does Emerson Edge Control Cut Cloud Dependency by 60%?
Emerson Edge Control Terminal processes OT data on-site, reducing latency to under 20ms and filtering 60% redundant d...
-
Low-Cost Brownfield Automation: Zero Downtime Possible?
This article shows how brownfield plants modernize legacy PLC and DCS systems using protocol gateways and edge termin...