Uyingizni eng so‘nggi ko‘p funksiyali elektronika yechimlari bilan o‘zgartiring, aqlli yoritishdan tortib ovozli boshqariladigan qurilmalargacha — bularning barchasi hayotingizni osonroq, xavfsizroq va yanada bog‘langan qilish uchun mo‘ljallangan.
SKU:330103-00-03-90-02-00
Bently Nevada 8mm Probe | 330103-00-03-90-02-00 9.0m
Manufacturer: Bently Nevada
Product No.: 330103-00-03-90-02-00
Product Type: Proximity Probe
Product Origin: USA
Payment:T/T, Western Union
Weight: 323g
Shipping port: Xiamen
Warranty: 12 months
Ulashish
- Tez yetkazib berish
- 24/7 Qo'llab-quvvatlash
- Sifat nazorati
Tavsif
Bently Nevada 330103-00-03-90-02-00 3300 XL 8mm Proximity Probe
Product Overview
Bently Nevada 330103-00-03-90-02-00 is a 3300 XL 8mm proximity probe with M10x1 thread without armor. Features 0mm unthreaded length and 30mm overall case length. 9.0 meter total length with Miniature coaxial ClickLoc connector. No agency approval required. Designed for radial vibration and position monitoring in large rotating machinery.
Model Number Decoder
| Position | Code | Meaning |
|---|---|---|
| 1 3 | 330103 | 3300 XL 8mm Probe, M10x1 thread, without armor |
| 4 5 | 00 | Unthreaded Length 0mm |
| 6 7 | 03 | Overall Case Length 30mm |
| 8 9 | 90 | Total Length 9.0 meters |
| 10 11 | 02 | Miniature coaxial ClickLoc connector, standard cable |
| 12 13 | 00 | No agency approval |
Technical Specifications
| Parameter | Value |
|---|---|
| Brand | Bently Nevada |
| Model | 330103-00-03-90-02-00 |
| Type | 3300 XL 8mm Proximity Probe |
| Thread | M10x1 |
| Tip Material | Polyphenylene sulfide (PPS) |
| Case Material | AISI 303/304 SST |
| Unthreaded Length | 0mm |
| Case Length | 30mm |
| Total Length | 9.0 meters |
| Connector | Miniature coaxial ClickLoc |
| Max Thread Engagement | 15 mm |
| DC Resistance | 9.87 Ω ±0.50 (9.0m) |
| Linear Range | 2 mm (80 mils) |
| Sensitivity | 7.87 V/mm (200 mV/mil) ±5% |
| Operating Temp Standard | 52°C to +177°C |
| Relative Humidity | ≤3% change at 93% RH |
| Hazardous Area | ATEX Zone 0, Class I Div 2 |
| Field Wiring Max Length | 305 m (1,000 ft) |
| Field Wiring Gauge | 16 24 AWG |
| Weight | 323 g/m (11.4 oz) |
Installation
Mount probe with M10x1 threaded case. Maximum thread engagement 15mm. Recommended gap for radial vibration is 9 VDC (1.27mm / 50 mils). Use 3 conductor shielded triad cable for field wiring. Maximum field wiring length 305 meters between Proximitor and monitor. Wire size 0.2 to 1.5 mm² (16 to 24 AWG).
Features
Extended 9.0 meter cable for long reach applications. Short 30mm case for reduced clearance requirements. TipLoc molding provides 330N pull strength. CableLoc design secures cable to probe body. PPS tip with thicker coil encapsulation. AISI 303/304 stainless steel case. Viton O ring pressure seal.
FAQ
Q1: What Proximitor sensor is required for this 9.0m probe?
A1: 9 meter probes are designed for use with the 9 meter Proximitor sensor only. Do not pair with 5 meter sensors.
Q2: What is the recommended gap setting for radial vibration?
A2: 9 VDC equals approximately 1.27mm (50 mils) for optimal linear range in radial vibration monitoring.
Q3: What is the DC resistance for 9.0m probe?
A3: 9.87 Ω ±0.50 measured from center conductor to outer conductor.
Qo'shimcha Texnik Tavsiflar
Skalyar (V/f)
Vektor
AC quvvatli
Sotib olish bo‘yicha qo‘llanma
- Buyurtma berishdan oldin aniq model, qism raqami va texnik xususiyatlarni tasdiqlang.
- Joriy mashinalaringiz yoki boshqaruv tizimlaringiz bilan mosligini ta’minlang.
- Texnik yordam uchun sale@etowonauto.com manzili yoki +8617859788089 raqamiga murojaat qiling.
- Yetkazib berish variantlari, yetkazib berish muddati va jo‘natish talablarini ko‘rib chiqing.
- O‘rnatish paytida ishlab chiqaruvchi ko‘rsatmalariga va eng yaxshi amaliyotlarga rioya qiling.
Yuborish va Qaytarish
Omborda mavjud bo‘lgan mahsulotlar odatda shu ish kuni jo‘natiladi. Hozirda omborda mavjud bo‘lmagan mahsulotlar uchun jo‘natish vaqti mavjudlikka qarab o‘zgarishi mumkin. Xalqaro yetkazib berish mavjud bo‘lib, yetkazib berish xarajatlari manzil, vazn va tashuvchi tanloviga ko‘ra hisoblanadi.
Qaytishlar qabul qilingan kundan boshlab 30 kun ichida amalga oshiriladi, agar mahsulotlar ishlatilmagan va asl holatda bo‘lsa. Qaytish xarajatlari mijoz zimmasida bo‘ladi. Iltimos, har qanday mahsulotni qaytarishdan oldin qaytish ruxsatini olish uchun biz bilan bog‘laning.
Batafsil ma’lumot uchun iltimos, Yetkazib berish va Qaytarish Siyosatini ko‘rib chiqing.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Tez yetkazib berish
Dunyoda tez yetkazib berish uchun original sanoat avtomatlashtirish qismlari mavjud.
-
Oson qaytarish
Ishonchli sotuvdan keyingi himoya uchun 12 oylik kafolat bilan 30 kunlik qaytarish qo'llab-quvvatlashi.
-
24/7 qo‘llab-quvvatlash
Barqaror va samarali ish faoliyatini ta'minlash uchun javobgar professional yordam.
-
Haqiqiy va Asl
100% haqiqiy, ishonchli sanoat avtomatlashtirish ishlab chiqaruvchilaridan to‘g‘ridan-to‘g‘ri olingan.
Texnik va Xarid Qollanmasi
-
Why Does PCS7 OS Server Redundancy Fail Over?
This guide explains how to diagnose and repair Siemens PCS7 OS server redundancy failover anomalies using quantified ...
-
How Do You Recover a Bricked Allen-Bradley PLC?
This article explains how industrial automation teams classify bricked Allen-Bradley Logix controllers, validate firm...
-
How Can You Prevent Historian Data Loss During Experion PKS Migration?
This article presents a measurable playbook for protecting Honeywell Experion historian data during server and H...
-
How Do MTL Barriers and DCS IO Cards Affect Loop Voltage?
Intrinsic safety circuits protect hazardous process areas, yet loop impedance budgeting often receives far less atten...
-
How Can You Tune GE RX3i and RX7i Ethernet for Heavy Industry?
Intermittent Ethernet timeouts on GE RX3i and RX7i controllers are among the hardest faults in heavy process plants, ...
-
Why Does FCS Redundancy Not Protect Your HIS Configuration?
This article examines the operational risks of Yokogawa CENTUM VP HIS lockups and explains why FCS controller re...