Uyingizni eng so‘nggi ko‘p funksiyali elektronika yechimlari bilan o‘zgartiring, aqlli yoritishdan tortib ovozli boshqariladigan qurilmalargacha — bularning barchasi hayotingizni osonroq, xavfsizroq va yanada bog‘langan qilish uchun mo‘ljallangan.
SKU:2090-CSWM1DE-14AA31
Allen-Bradley Servo Power Cable 2090-CSWM1DE-14AA31
Manufacturer: Allen-Bradley
Product No.: 2090-CSWM1DE-14AA31
Product Type: Kinetix Cable
Product Origin: USA
Payment:T/T, Western Union
Weight: 2000g
Shipping port: Xiamen
Warranty: 12 months
Ulashish
- Tez yetkazib berish
- 24/7 Qo'llab-quvvatlash
- Sifat nazorati
Tavsif
Product Identification
- Product Type: Single DSL Servo Cable with Connector Kit & SpeedTec DIN
- Series: Kinetix Compatible
- Brand: Allen-Bradley
Loading & Installation Specifications
- Maximum Pull Force: 150N (34 lbf) during installation
- Bend Radius During Installation: Minimum 10× cable diameter
- Termination Torque: 0.6±0.1 Nm for connector screws
- Cable Clamping Force: 50-70N recommended
- Storage Temperature: -40°C to +70°C (prior to installation)
Cable Construction
- Conductor: 14 AWG (2.08mm²) stranded copper
- Insulation: Dual-layer XLPE (0.5mm+0.3mm)
- Shielding: 90% coverage spiral copper + aluminum foil
- Jacket: 1.2mm thick abrasion-resistant PUR
- Cable Stiffness: 350N/mm bending resistance
- Weight: 380g per meter (typical)
Performance Data
- Voltage Rating: 800V AC/DC (IEC 60204 compliant)
- Current Capacity: 25A continuous @ 50°C
- Signal Integrity: <1% voltage drop at 10m length
- Propagation Delay: 4.5ns/m typical
- Impedance: 120Ω ±15% (1-100MHz)
Mechanical Durability
- Vibration Resistance: 10-500Hz, 15G (3 axes)
- Flex Life: >2M cycles @ 8× diameter
- Crush Resistance: 1000N/100mm width
- Torsion Rating: ±180°/meter, 5000 cycles
Documentation
FAQ
What is the maximum pull force during installation?
150N (34 lbf) maximum to prevent cable damage during pulling.
What is the current capacity of this cable?
25A continuous at 50°C with 800V AC/DC voltage rating.
What is the flex life rating?
>2 million cycles at 8× cable diameter with ±180°/meter torsion rating.
Qo'shimcha Texnik Tavsiflar
- Apelsin
Skalyar (V/f)
Vektor
AC quvvatli
Sotib olish bo‘yicha qo‘llanma
- Buyurtma berishdan oldin aniq model, qism raqami va texnik xususiyatlarni tasdiqlang.
- Joriy mashinalaringiz yoki boshqaruv tizimlaringiz bilan mosligini ta’minlang.
- Texnik yordam uchun sale@etowonauto.com manzili yoki +8617859788089 raqamiga murojaat qiling.
- Yetkazib berish variantlari, yetkazib berish muddati va jo‘natish talablarini ko‘rib chiqing.
- O‘rnatish paytida ishlab chiqaruvchi ko‘rsatmalariga va eng yaxshi amaliyotlarga rioya qiling.
Yuborish va Qaytarish
Omborda mavjud bo‘lgan mahsulotlar odatda shu ish kuni jo‘natiladi. Hozirda omborda mavjud bo‘lmagan mahsulotlar uchun jo‘natish vaqti mavjudlikka qarab o‘zgarishi mumkin. Xalqaro yetkazib berish mavjud bo‘lib, yetkazib berish xarajatlari manzil, vazn va tashuvchi tanloviga ko‘ra hisoblanadi.
Qaytishlar qabul qilingan kundan boshlab 30 kun ichida amalga oshiriladi, agar mahsulotlar ishlatilmagan va asl holatda bo‘lsa. Qaytish xarajatlari mijoz zimmasida bo‘ladi. Iltimos, har qanday mahsulotni qaytarishdan oldin qaytish ruxsatini olish uchun biz bilan bog‘laning.
Batafsil ma’lumot uchun iltimos, Yetkazib berish va Qaytarish Siyosatini ko‘rib chiqing.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Tez yetkazib berish
Dunyoda tez yetkazib berish uchun original sanoat avtomatlashtirish qismlari mavjud.
-
Oson qaytarish
Ishonchli sotuvdan keyingi himoya uchun 12 oylik kafolat bilan 30 kunlik qaytarish qo'llab-quvvatlashi.
-
24/7 qo‘llab-quvvatlash
Barqaror va samarali ish faoliyatini ta'minlash uchun javobgar professional yordam.
-
Haqiqiy va Asl
100% haqiqiy, ishonchli sanoat avtomatlashtirish ishlab chiqaruvchilaridan to‘g‘ridan-to‘g‘ri olingan.
Texnik va Xarid Qollanmasi
-
Can PLC and DCS Replace Dedicated TSI Protection?
This article examines why critical rotating machinery requires independent safety barriers separate from standard PLC...
-
Can Bently Nevada TSI Prevent Turbine Trips in Automation?
This technical article examines why standard PLC and DCS process monitoring fails to detect early-stage rotating mach...
-
Can Staged Hardware Upgrades Eliminate Unplanned Downtime?
This technical article examines the hidden risks of ageing Allen‑Bradley PLC and DCS hardware in continuous process e...
-
Is Protocol Conversion Key to Unified Factory Automation?
Mixed-vendor PLC and DCS environments create significant operational inefficiencies and unplanned downtime in modern ...
-
Can a Bently Nevada TSI Retrofit Cut False Alarms 71.8%?
This technical guide examines the strategic approach to partial TSI system retrofits for Bently Nevada 3500 series ha...
-
Can Long-Term Vibration Trends Predict Rotating Equipment Fatigue?
Standard PLC and DCS systems often fail to detect progressive mechanical fatigue because they prioritize process vari...
