Uyingizni eng so‘nggi ko‘p funksiyali elektronika yechimlari bilan o‘zgartiring, aqlli yoritishdan tortib ovozli boshqariladigan qurilmalargacha — bularning barchasi hayotingizni osonroq, xavfsizroq va yanada bog‘langan qilish uchun mo‘ljallangan.
SKU:25A-B2P5N104
Allen-Bradley 25A-B2P5N104 PowerFlex 523 Drive 0.75kW 2.5A
Manufacturer: Allen-Bradley
Product No.: 25A-B2P5N104
Product Type: AC Drive
Product Origin: USA
Payment:T/T, Western Union
Weight: 1100g
Shipping port: Xiamen
Warranty: 12 months
Ulashish
- Tez yetkazib berish
- 24/7 Qo'llab-quvvatlash
- Sifat nazorati
Tavsif
Allen-Bradley 25A-B2P5N104 PowerFlex 523 AC Drive
The Allen-Bradley 25A-B2P5N104 is a PowerFlex 523 series AC drive delivering 0.75 kW (1 HP) output. Operating on 208-240 VAC three-phase input, this Frame A drive provides 2.5 Amps output current with V/Hz control. Built-in Modbus RTU (RS485) communication enables flexible integration. Weighing approximately 1.2 kg (2.65 lbs), this drive features natural convection cooling and IP20 enclosure for panel mounting applications.
Technical Specifications
| Parameter | Value |
|---|---|
| Manufacturer | Allen-Bradley (Rockwell Automation) |
| Model Number | 25A-B2P5N104 |
| Series | PowerFlex 523 |
| Frame Size | Frame A |
| Cooling | Natural convection cooling |
| Maximum Output Frequency | 60 Hz |
| Control Method | V/Hz Control |
| Nominal Power Output | 0.75 kW (1 HP) |
| Output Current | 2.5 Amps |
| Input Voltage | 208-240 VAC (Three-Phase) |
| Operating Temperature | -10°C to +50°C (14°F to 122°F) |
| Enclosure Type | IP20 / Open Type |
| Communication Ports | Built-in Modbus RTU (RS485) |
| Interface Module | Standard module |
| Mounting Options | Wall mount or panel mount |
| EMC Filtering | Not included |
| Protection Features | Overload, Overvoltage, Undervoltage, Overcurrent, Short Circuit |
Model Number Breakdown
- 25A – PowerFlex 523 Series
- B – 208-240V AC Input
- 2P5 – 2.5 Amp Output
- N – No EMC Filter
- 104 – Standard Interface Module
Installation & Field Application Guide
- Mount the drive vertically on a flat, non-combustible surface. Allow minimum 50mm clearance above and below for natural convection airflow.
- Size input and output wiring per local electrical codes. Use 14 AWG minimum for power connections.
- Connect RS485 communication wires twisted-pair shielded. Ground the shield at the drive end only.
- Set motor parameters (voltage, current, frequency) during initial commissioning using the integrated keypad or software.
Why Choose the 25A-B2P5N104
- Compact Frame A design saves panel space while delivering 0.75kW output.
- Built-in Modbus RTU enables direct connection to PLCs and SCADA systems.
- Comprehensive protection features safeguard the drive and connected motor.
- Natural convection cooling eliminates fan maintenance and reduces noise.
Field Engineer FAQs
Q1: What is the maximum cable length for Modbus RTU communication?
A1: For RS485 Modbus RTU, maximum cable length is 1200 meters (4000 feet) at baud rates up to 115.2 kbps. Use 120-ohm termination resistors at both ends for long runs.
Q2: Can this drive be used for single-phase input?
A2: No, the 25A-B2P5N104 requires three-phase 208-240V AC input. Single-phase operation will cause under-voltage faults.
Q3: Does this drive support a braking resistor?
A3: Yes, Frame A drives support optional braking resistors for rapid deceleration of high-inertia loads. Use a resistor rated for 5% duty cycle at the drive output.
Inquiries: sale@etowonauto.com
Qo'shimcha Texnik Tavsiflar
Skalyar (V/f)
Vektor
AC quvvatli
Sotib olish bo‘yicha qo‘llanma
- Buyurtma berishdan oldin aniq model, qism raqami va texnik xususiyatlarni tasdiqlang.
- Joriy mashinalaringiz yoki boshqaruv tizimlaringiz bilan mosligini ta’minlang.
- Texnik yordam uchun sale@etowonauto.com manzili yoki +8617859788089 raqamiga murojaat qiling.
- Yetkazib berish variantlari, yetkazib berish muddati va jo‘natish talablarini ko‘rib chiqing.
- O‘rnatish paytida ishlab chiqaruvchi ko‘rsatmalariga va eng yaxshi amaliyotlarga rioya qiling.
Yuborish va Qaytarish
Omborda mavjud bo‘lgan mahsulotlar odatda shu ish kuni jo‘natiladi. Hozirda omborda mavjud bo‘lmagan mahsulotlar uchun jo‘natish vaqti mavjudlikka qarab o‘zgarishi mumkin. Xalqaro yetkazib berish mavjud bo‘lib, yetkazib berish xarajatlari manzil, vazn va tashuvchi tanloviga ko‘ra hisoblanadi.
Qaytishlar qabul qilingan kundan boshlab 30 kun ichida amalga oshiriladi, agar mahsulotlar ishlatilmagan va asl holatda bo‘lsa. Qaytish xarajatlari mijoz zimmasida bo‘ladi. Iltimos, har qanday mahsulotni qaytarishdan oldin qaytish ruxsatini olish uchun biz bilan bog‘laning.
Batafsil ma’lumot uchun iltimos, Yetkazib berish va Qaytarish Siyosatini ko‘rib chiqing.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Tez yetkazib berish
Dunyoda tez yetkazib berish uchun original sanoat avtomatlashtirish qismlari mavjud.
-
Oson qaytarish
Ishonchli sotuvdan keyingi himoya uchun 12 oylik kafolat bilan 30 kunlik qaytarish qo'llab-quvvatlashi.
-
24/7 qo‘llab-quvvatlash
Barqaror va samarali ish faoliyatini ta'minlash uchun javobgar professional yordam.
-
Haqiqiy va Asl
100% haqiqiy, ishonchli sanoat avtomatlashtirish ishlab chiqaruvchilaridan to‘g‘ridan-to‘g‘ri olingan.
Texnik va Xarid Qollanmasi
-
Can ABB AC500 redundant power eliminate mill downtime?
This technical article examines how ABB AC500 redundant power modules resolve unplanned downtime caused by voltage...
-
Is Your Wastewater Plant Ready for a Data-Driven Upgrade?
This technical article examines the operational bottlenecks of legacy wastewater treatment automation and presents a ...
-
Can Eddy-Current Probes Prevent LNG Compressor Shutdowns?
This technical article examines how Bently Nevada eddy-current proximity probes provide high-precision vibration...
-
Can SIL 3 PLCs Really Slash $1M in Annual Offshore Maintenance?
This technical article examines how Allen‑Bradley GuardPLC SIL 3 safety controllers reduce unplanned offshore downtim...
-
Can Emerson DeltaV DCS Cards Optimize Chemical Safety Loops?
This technical article examines how Emerson DeltaV DCS card upgrades address legacy control limitations in chemical p...
-
Is Partial CNC Board Replacement Better Than a Full System Upgrade?
This technical article examines the dominance of GE Fanuc CNC hardware in heavy-duty automation, supported by field d...