Uyingizni eng so‘nggi ko‘p funksiyali elektronika yechimlari bilan o‘zgartiring, aqlli yoritishdan tortib ovozli boshqariladigan qurilmalargacha — bularning barchasi hayotingizni osonroq, xavfsizroq va yanada bog‘langan qilish uchun mo‘ljallangan.
SKU:1746-NT8
Allen-Bradley 1746-NT8 | SLC 500 Thermocouple Input Module 8-Ch
Manufacturer: Allen-Bradley
Product No.: 1746-NT8
Product Type: Thermocouple Input Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 340g
Shipping port: Xiamen
Warranty: 12 months
Ulashish
- Tez yetkazib berish
- 24/7 Qo'llab-quvvatlash
- Sifat nazorati
Tavsif
Product Overview
The Allen-Bradley 1746-NT8 is an 8-channel Thermocouple/mV Analog Input Module for the SLC 500 system. It accepts J, K, T, E, S, R, B, and N thermocouple types, as well as ±50mV and ±100mV signals. This module delivers 16-bit resolution with Sigma-Delta conversion for precise temperature measurement.
Core Functionality
The 1746-NT8 converts analog thermocouple or millivolt signals to digital values for SLC 500 processors. It features automatic calibration every 2 minutes, selectable filter frequencies, and open-circuit detection (zero, upscale, or downscale). Two cold-junction compensation sensors on the 1746-RT34 terminal block ensure accurate temperature readings. The module supports engineering units, PID-scaled, or proportional counts data formats.
Technical Specifications
| Parameter | Value |
| Part Number | 1746-NT8 |
| Series | SLC 500 |
| Module Type | Thermocouple/mV Analog Input |
| Inputs | 8 channels |
| Thermocouple Types | J, K, T, E, S, R, B, N |
| Millivolt Inputs | ±50mV, ±100mV |
| Resolution | 16-bit in / 14-bit out |
| A/D Conversion | Sigma-Delta modulation |
| Update Time | 356ms to 4.05s |
| Backplane Current (5V / 24V) | 120mA / 70mA |
| Backplane Power | 2.28W max |
| Input Impedance | >10MΩ |
| Overvoltage Protection | ±30V DC (600W pulse) |
| Isolation (Input to Backplane) | 500V DC for 1 min |
| Open Circuit Detection | Zero / Upscale / Downscale |
| CJC Accuracy | ±1.72°C |
| Operating Temperature | 0°C to 60°C |
| Weight | 0.34 kg (0.75 lbs) |
Installation Guide
Install the 1746-NT8 in any SLC 500 chassis slot except Slot 0 (reserved for CPU or communication adapters). Connect thermocouple or millivolt sensors using the 1746-RT34 removable terminal block. The terminal block includes two CJC sensors. Ensure input devices have impedance under 100Ω for rated accuracy. Configure input type and data format (engineering units, PID-scaled, or proportional counts) in the SLC 500 program.
Engineering Advantages
This module supports eight thermocouple types plus millivolt inputs, offering flexibility for diverse temperature measurement applications. Sigma-Delta conversion with programmable filtering provides noise rejection >100dB at 50-60Hz. Automatic calibration ensures long-term accuracy. Open-circuit detection with selectable response helps identify sensor faults. The module fits both fixed and modular SLC 500 systems.
Technical FAQs
Q1: Supported thermocouple types?
A1: J, K, T, E, S, R, B, and N. Also supports ±50mV and ±100mV inputs.
Q2: Where to install the module?
A2: Any SLC 500 chassis slot except Slot 0. Slot 0 is reserved for processor or communication adapters.
Q3: Update time and resolution?
A3: Update time 356ms to 4.05s (filter dependent). Resolution 16-bit in / 14-bit out.
Qo'shimcha Texnik Tavsiflar
Skalyar (V/f)
Vektor
AC quvvatli
Sotib olish bo‘yicha qo‘llanma
- Buyurtma berishdan oldin aniq model, qism raqami va texnik xususiyatlarni tasdiqlang.
- Joriy mashinalaringiz yoki boshqaruv tizimlaringiz bilan mosligini ta’minlang.
- Texnik yordam uchun sale@etowonauto.com manzili yoki +8617859788089 raqamiga murojaat qiling.
- Yetkazib berish variantlari, yetkazib berish muddati va jo‘natish talablarini ko‘rib chiqing.
- O‘rnatish paytida ishlab chiqaruvchi ko‘rsatmalariga va eng yaxshi amaliyotlarga rioya qiling.
Yuborish va Qaytarish
Omborda mavjud bo‘lgan mahsulotlar odatda shu ish kuni jo‘natiladi. Hozirda omborda mavjud bo‘lmagan mahsulotlar uchun jo‘natish vaqti mavjudlikka qarab o‘zgarishi mumkin. Xalqaro yetkazib berish mavjud bo‘lib, yetkazib berish xarajatlari manzil, vazn va tashuvchi tanloviga ko‘ra hisoblanadi.
Qaytishlar qabul qilingan kundan boshlab 30 kun ichida amalga oshiriladi, agar mahsulotlar ishlatilmagan va asl holatda bo‘lsa. Qaytish xarajatlari mijoz zimmasida bo‘ladi. Iltimos, har qanday mahsulotni qaytarishdan oldin qaytish ruxsatini olish uchun biz bilan bog‘laning.
Batafsil ma’lumot uchun iltimos, Yetkazib berish va Qaytarish Siyosatini ko‘rib chiqing.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Tez yetkazib berish
Dunyoda tez yetkazib berish uchun original sanoat avtomatlashtirish qismlari mavjud.
-
Oson qaytarish
Ishonchli sotuvdan keyingi himoya uchun 12 oylik kafolat bilan 30 kunlik qaytarish qo'llab-quvvatlashi.
-
24/7 qo‘llab-quvvatlash
Barqaror va samarali ish faoliyatini ta'minlash uchun javobgar professional yordam.
-
Haqiqiy va Asl
100% haqiqiy, ishonchli sanoat avtomatlashtirish ishlab chiqaruvchilaridan to‘g‘ridan-to‘g‘ri olingan.
Texnik va Xarid Qollanmasi
-
Can a Phased Retrofit Cut Your GE Upgrade Costs by Over 50%?
This article examines strategic approaches to modernizing legacy GE PLC and DCS systems in brown‑field industrial sit...
-
How does off-site monitoring cut fault diagnosis time by 79%?
This article examines how GE long-distance data transmission enables off-site centralized monitoring for geographi...
-
How Do Bently Nevada Transmitters Improve Bearing Health Monitoring?
This technical article examines the role of Bently Nevada vibration transmitters in industrial automation for ea...
-
What Are the Real ROI Gains of Upgrading Legacy Turbine Monitoring?
Operating legacy turbine supervisory instrumentation (TSI) beyond 12 years exposes power stations to false trips, pro...
-
How Does 3500/22M Improve Mixed-Vendor Safety Integration?
This article examines the measurable performance gap between Bently Nevada's legacy 3500/22 and the upgraded 3500/22M...
-
Fixed Gas Detector or Transmitter: Which Fits Your Plant?
This article examines the practical differences between fixed gas detectors and gas detection transmitters in industr...
