Uyingizni eng so‘nggi ko‘p funksiyali elektronika yechimlari bilan o‘zgartiring, aqlli yoritishdan tortib ovozli boshqariladigan qurilmalargacha — bularning barchasi hayotingizni osonroq, xavfsizroq va yanada bog‘langan qilish uchun mo‘ljallangan.
SKU:6ES7431-1KF00-0AB0
6ES7431-1KF00-0AB0 | Siemens S7-400 SM 431 Analog Input
Manufacturer: Siemens
Product No.: 6ES7431-1KF00-0AB0
Product Type: Analog Input Module
Product Origin: DE
Payment:T/T, Western Union
Weight: 500g
Shipping port: Xiamen
Warranty: 12 months
Ulashish
- Tez yetkazib berish
- 24/7 Qo'llab-quvvatlash
- Sifat nazorati
Tavsif
6ES7431-1KF00-0AB0 Siemens SIMATIC S7-400 SM 431 Isolated Analog Input Module – 8 AI
The Siemens 6ES7431-1KF00-0AB0 is an isolated analog input module from the SIMATIC S7-400 series. Provides 8 isolated analog input channels with 13-bit resolution and resistance measurement capability. Weight is approximately 500 g.
Product Information
| Manufacturer | Siemens |
| Part Number | 6ES7431-1KF00-0AB0 |
| Product Type | Analog Input Module SM 431 |
| Series | SIMATIC S7-400 |
| Number of Analog Inputs | 8 (4 for Resistance Measurement) |
| Resolution | 13 Bit Including Sign |
| Isolation | Isolated (Internal/External) |
| Dimensions (W x H x D) | 25 x 290 x 210 mm |
| Weight | Approx. 500 g |
Input Ranges and Resistance
| Voltage Range 1-5V | Input Resistance 200 kΩ |
| Voltage Range -1 to +1V | Input Resistance 200 kΩ |
| Voltage Range -10 to +10V | Input Resistance 200 kΩ |
| Current Range -20 to +20 mA | Input Resistance 80 Ω |
| Current Range 4-20 mA | Input Resistance 80 Ω |
| Resistance Range 0-600 Ω | Usable Up to 500 Ω |
Supply and Conversion Specifications
| Load Voltage L+ | Not Necessary |
| Input Current from Backplane (5V DC) | 350 mA Max |
| Power Loss (Typical) | 1.8 W |
| Basic Conversion Time | 23 / 25 ms |
| Integration Time | 16.7 / 20 ms |
| Interference Frequency Suppression | 50 / 60 Hz |
| Module Basic Execution Time | 200 ms (184/200 ms) |
Accuracy Specifications
| Temperature Error | ±0.02%/K (Impedance), ±0.007% (Other Ranges) |
| Operational Error (Voltage) | ±1% (±1.0% at ±1V, ±0.6% at ±10V, ±0.7% at 1-5V) |
| Operational Error (Current) | ±1% |
| Operational Error (Resistance) | ±1.25% (0-500 Ω, 4-Conductor) |
| Basic Error at 25°C (Voltage) | ±0.7% (0.7% at ±1V, 0.4% at ±10V, 0.5% at 1-5V) |
| Basic Error at 25°C (Current) | ±0.7% |
| Basic Error at 25°C (Resistance) | ±0.8% (0-500 Ω, 4-Conductor) |
Protection and Isolation
| Input Voltage Destruction Limit | 50V |
| Input Current Destruction Limit | 50 mA (40 mA Continuous) |
| Constant Measurement Current | 1.67 mA Typical (Resistance Transmitter) |
| Potential Separation | Analog Inputs (Internal/External), Channels to Backplane Bus |
| Isolation (Bus to Analog) | 2120V DC |
| Isolation (Bus to Ground) | 500V DC |
| Isolation (Analog to Ground) | 2120V DC |
| Cable Length (Shielded) | 200 m Max |
Features
- 8 isolated analog input channels
- 13-bit resolution including sign
- Voltage ranges: 1-5V, ±1V, ±10V
- Current ranges: ±20 mA, 4-20 mA
- Resistance measurement: 0-600 Ω (usable up to 500 Ω)
- Fast 23 ms basic conversion time
- 2-wire, 3-wire, and 4-wire resistance measurement support
- Compact 25 mm width design
Applications
- SIMATIC S7-400 control systems
- Industrial automation
- Process control
- Resistance and temperature monitoring
- Analog signal acquisition
FAQs
Q1: How many analog inputs does the 6ES7431-1KF00-0AB0 provide?
A1: 8 isolated analog input channels with 13-bit resolution, including 4 channels for resistance measurement.
Q2: What input ranges are supported?
A2: Voltage 1-5V, ±1V, ±10V; current ±20 mA, 4-20 mA; resistance 0-600 Ω (usable up to 500 Ω).
Q3: What is the weight and conversion time?
A3: Approximately 500 g with basic conversion time of 23/25 ms.
Qo'shimcha Texnik Tavsiflar
- Kulrang
Skalyar (V/f)
Vektor
AC quvvatli
Sotib olish bo‘yicha qo‘llanma
- Buyurtma berishdan oldin aniq model, qism raqami va texnik xususiyatlarni tasdiqlang.
- Joriy mashinalaringiz yoki boshqaruv tizimlaringiz bilan mosligini ta’minlang.
- Texnik yordam uchun sale@etowonauto.com manzili yoki +8617859788089 raqamiga murojaat qiling.
- Yetkazib berish variantlari, yetkazib berish muddati va jo‘natish talablarini ko‘rib chiqing.
- O‘rnatish paytida ishlab chiqaruvchi ko‘rsatmalariga va eng yaxshi amaliyotlarga rioya qiling.
Yuborish va Qaytarish
Omborda mavjud bo‘lgan mahsulotlar odatda shu ish kuni jo‘natiladi. Hozirda omborda mavjud bo‘lmagan mahsulotlar uchun jo‘natish vaqti mavjudlikka qarab o‘zgarishi mumkin. Xalqaro yetkazib berish mavjud bo‘lib, yetkazib berish xarajatlari manzil, vazn va tashuvchi tanloviga ko‘ra hisoblanadi.
Qaytishlar qabul qilingan kundan boshlab 30 kun ichida amalga oshiriladi, agar mahsulotlar ishlatilmagan va asl holatda bo‘lsa. Qaytish xarajatlari mijoz zimmasida bo‘ladi. Iltimos, har qanday mahsulotni qaytarishdan oldin qaytish ruxsatini olish uchun biz bilan bog‘laning.
Batafsil ma’lumot uchun iltimos, Yetkazib berish va Qaytarish Siyosatini ko‘rib chiqing.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Tez yetkazib berish
Dunyoda tez yetkazib berish uchun original sanoat avtomatlashtirish qismlari mavjud.
-
Oson qaytarish
Ishonchli sotuvdan keyingi himoya uchun 12 oylik kafolat bilan 30 kunlik qaytarish qo'llab-quvvatlashi.
-
24/7 qo‘llab-quvvatlash
Barqaror va samarali ish faoliyatini ta'minlash uchun javobgar professional yordam.
-
Haqiqiy va Asl
100% haqiqiy, ishonchli sanoat avtomatlashtirish ishlab chiqaruvchilaridan to‘g‘ridan-to‘g‘ri olingan.
Texnik va Xarid Qollanmasi
-
Is Compact DCS Better Than PLC for Small Plants?
This article examines the ABB AC700F Freelance DCS as a compact control solution for small batch process plants ...
-
What Makes ControlEdge UCD Ideal for Water Treatment DCS?
Honeywell ControlEdge UCD DCS delivers DCS-grade reliability in a compact, PLC-like footprint suited to mid-size muni...
-
Why Is Redundant DCS Essential for 24/7 Process Automation?
ABB Freelance AC900F redundant DCS delivers hot standby CPU switching within 5 ms, hot-swappable S700 I/O, and verifi...
-
What Makes Honeywell C200 DCS Installation Standards So Critical?
This article examines Honeywell Experion PKS C200 DCS installation standards, key technical parameters, CPU and I/O f...
-
How Can You Avoid Hidden Faults in Logix5000 PLC Migration?
Allen-Bradley Logix5000 migration involves far more than a firmware flash. Version jumps from V20 to V30 can add 0.4 ...
-
How Do Thermal Stress and Aging Affect Ovation I/O Module Life?
This article explains how thermal stress, vibration and capacitor aging degrade Emerson Ovation I/O modules in power ...