Uyingizni eng so‘nggi ko‘p funksiyali elektronika yechimlari bilan o‘zgartiring, aqlli yoritishdan tortib ovozli boshqariladigan qurilmalargacha — bularning barchasi hayotingizni osonroq, xavfsizroq va yanada bog‘langan qilish uchun mo‘ljallangan.
SKU:3500/15-03-03-01
3500/15-03-03-01 Bently Nevada Dual DC Supply 1.39kg
Manufacturer: Bently Nevada
Product No.: 3500/15-03-03-01
Product Type: Power Supply
Product Origin: USA
Payment:T/T, Western Union
Weight: 1390g
Shipping port: Xiamen
Warranty: 12 months
Ulashish
- Tez yetkazib berish
- 24/7 Qo'llab-quvvatlash
- Sifat nazorati
Tavsif
Bently Nevada 3500/15-03-03-01 Power Supply Module
Bently Nevada 3500/15-03-03-01 is a power supply module for the 3500 monitoring system. Features High Voltage DC (88-140V DC) in top slot and High Voltage DC (88-140V DC) in bottom slot. CSA / NRTL / C Class 1 Division 2 approved. Weight: 1.39 kg (3.1 lbs).
Technical Specifications
| Parameter | Specification |
| Manufacturer | Bently Nevada |
| Model | 3500/15-03-03-01 |
| Product Type | Power Supply Module |
| Top Slot Supply | High Voltage DC (88-140V DC) |
| Bottom Slot Supply | High Voltage DC (88-140V DC) |
| Agency Approval | CSA / NRTL / C (Class 1 Division 2) |
| Operating Temperature | -30°C to +65°C (-22°F to +150°F) |
| Storage Temperature | -40°C to +85°C (-40°F to +185°F) |
| Humidity | 95% non-condensing |
| Dimensions (H x W x D) | 120.7 × 50.8 × 251.5 mm |
| Weight | 1.39 kg (3.1 lbs) |
Configuration Breakdown
| Code | Description |
| 03 | High Voltage DC (88-140V DC) - Top Slot |
| 03 | High Voltage DC (88-140V DC) - Bottom Slot |
| 01 | CSA / NRTL / C (Class 1 Division 2) |
Key Features
- Dual high-voltage DC power supplies for redundant operation
- CSA / NRTL / C Class 1 Division 2 certified for hazardous areas
- Wide operating temperature range -30°C to +65°C
- Provides regulated power to 3500 monitoring system rack
- Compact form factor for standard 3500 rack installation
Installation Guidelines (Field Engineer Notes)
Slot Placement: Top and bottom slots both require High Voltage DC supplies. Ensure both modules are properly seated and locked.
Wiring: Use 14 AWG minimum for DC input wiring. Connect positive to L1 and negative to L2. Torque terminals to 0.8 N·m (7 in·lb). Connect earth ground to chassis ground lug before energizing.
Voltage Verification: Measure incoming DC at the terminal block before inserting modules. Verify 88-140V DC between L1 and L2. Polarity must be correct.
Redundancy: Dual supplies provide hot-standby redundancy. If one supply fails, the second continues powering the rack without interruption.
Fuse Check: Each supply has internal fuses. Before replacing a module, check AC/DC input and fuse condition on the front panel.
FAQs
Q1. Can I mix AC and DC supplies in this configuration?
A1. No. This configuration uses High Voltage DC in both slots. Mixing AC and DC supplies requires a different part number with appropriate slot codes.
Q2. What is the maximum rack load for dual DC supplies?
A2. Each DC supply provides 2.5A maximum. Dual supplies share the load. Total rack current should not exceed 5A.
Q3. How do I test redundancy operation?
A3. Remove one supply while the rack is running. The second supply should maintain power with no interruption. Green LED on the remaining supply stays lit. Replace the removed supply within 30 seconds.
Download
Qo'shimcha Texnik Tavsiflar
- Koʻk
Skalyar (V/f)
Vektor
AC quvvatli
Sotib olish bo‘yicha qo‘llanma
- Buyurtma berishdan oldin aniq model, qism raqami va texnik xususiyatlarni tasdiqlang.
- Joriy mashinalaringiz yoki boshqaruv tizimlaringiz bilan mosligini ta’minlang.
- Texnik yordam uchun sale@etowonauto.com manzili yoki +8617859788089 raqamiga murojaat qiling.
- Yetkazib berish variantlari, yetkazib berish muddati va jo‘natish talablarini ko‘rib chiqing.
- O‘rnatish paytida ishlab chiqaruvchi ko‘rsatmalariga va eng yaxshi amaliyotlarga rioya qiling.
Yuborish va Qaytarish
Omborda mavjud bo‘lgan mahsulotlar odatda shu ish kuni jo‘natiladi. Hozirda omborda mavjud bo‘lmagan mahsulotlar uchun jo‘natish vaqti mavjudlikka qarab o‘zgarishi mumkin. Xalqaro yetkazib berish mavjud bo‘lib, yetkazib berish xarajatlari manzil, vazn va tashuvchi tanloviga ko‘ra hisoblanadi.
Qaytishlar qabul qilingan kundan boshlab 30 kun ichida amalga oshiriladi, agar mahsulotlar ishlatilmagan va asl holatda bo‘lsa. Qaytish xarajatlari mijoz zimmasida bo‘ladi. Iltimos, har qanday mahsulotni qaytarishdan oldin qaytish ruxsatini olish uchun biz bilan bog‘laning.
Batafsil ma’lumot uchun iltimos, Yetkazib berish va Qaytarish Siyosatini ko‘rib chiqing.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Tez yetkazib berish
Dunyoda tez yetkazib berish uchun original sanoat avtomatlashtirish qismlari mavjud.
-
Oson qaytarish
Ishonchli sotuvdan keyingi himoya uchun 12 oylik kafolat bilan 30 kunlik qaytarish qo'llab-quvvatlashi.
-
24/7 qo‘llab-quvvatlash
Barqaror va samarali ish faoliyatini ta'minlash uchun javobgar professional yordam.
-
Haqiqiy va Asl
100% haqiqiy, ishonchli sanoat avtomatlashtirish ishlab chiqaruvchilaridan to‘g‘ridan-to‘g‘ri olingan.
Texnik va Xarid Qollanmasi
-
Can Eddy-Current Probes Prevent LNG Compressor Shutdowns?
This technical article examines how Bently Nevada eddy-current proximity probes provide high-precision vibration...
-
Can SIL 3 PLCs Really Slash $1M in Annual Offshore Maintenance?
This technical article examines how Allen‑Bradley GuardPLC SIL 3 safety controllers reduce unplanned offshore downtim...
-
Can Emerson DeltaV DCS Cards Optimize Chemical Safety Loops?
This technical article examines how Emerson DeltaV DCS card upgrades address legacy control limitations in chemical p...
-
Is Partial CNC Board Replacement Better Than a Full System Upgrade?
This technical article examines the dominance of GE Fanuc CNC hardware in heavy-duty automation, supported by field d...
-
Can Genuine PLC Modules Cut DCS Downtime 60%?
This article examines how genuine Allen-Bradley PLC module replacement strategies directly reduce unplanned DCS downt...
-
Is Your GE Fanuc PLC Talking to ABB DCS?
This article reveals how cross-system data silos between GE Fanuc PLC and ABB DCS cause 8–15% production losses in pr...