Uyingizni eng so‘nggi ko‘p funksiyali elektronika yechimlari bilan o‘zgartiring, aqlli yoritishdan tortib ovozli boshqariladigan qurilmalargacha — bularning barchasi hayotingizni osonroq, xavfsizroq va yanada bog‘langan qilish uchun mo‘ljallangan.
SKU:140DDI35310C
140DDI35310C 24V DC Discrete Input Module Schneider
Manufacturer: Schneider
Product No.: 140DDI35310C
Product Type: Input Module
Product Origin: FR
Payment:T/T, Western Union
Weight: 300g
Shipping port: Xiamen
Warranty: 12 months
Ulashish
- Tez yetkazib berish
- 24/7 Qo'llab-quvvatlash
- Sifat nazorati
Tavsif
Overview
The Schneider Electric 140DDI35310C is a discrete input module for Modicon Quantum systems. It provides 32 sink inputs with 24V DC negative logic.
Key Specifications
- Manufacturer: Schneider Electric – Modicon Quantum series
- Model: 140DDI35310C – Discrete input module
- Channels: 32 inputs, negative logic (sink)
- Input Voltage: 24V DC (19.2-30V range)
- Response Time: ≤1ms ON to OFF, ≤1ms OFF to ON
- Impedance: 2400 Ohm per channel
Input Groups
- 32 channels split into 4 groups of 8 inputs.
- State 1 guaranteed: -30 to -15V DC at ≥2.5mA.
- State 0 guaranteed: -5 to 0V DC at ≤0.5mA.
- Requires 2 input words for addressing.
Protection
- Input protection by resistor limiting current.
- Withstands 30V continuous, 50V for 1ms pulse.
- Max leakage current: 200mA at 5.5V.
- Power dissipation: 1.5W + (0.26 × active channels).
Isolation
- Group-to-bus isolation: 1780Vrms for 1 minute.
- Inter-group isolation: 500Vrms for 1 minute.
- Bus current requirement: 330mA.
- Standard format fits Quantum backplanes.
Package & Shipping
- Dimensions: 16.3 × 4.5 × 31.2 cm, net weight 0.3 kg.
- Includes: One 140DDI35310C module with documentation.
- Shipping: Fast delivery via FedEx, UPS, or DHL.
FAQ
Q: What is negative logic sink input?
A: The module reads signals referenced to ground. Current sinks from input to common when activated.
Q: How does 140DDI35310C differ from 140DDI35300C?
A: 140DDI35310C uses negative logic. 140DDI35300C uses positive logic. Choose based on your field device wiring.
Q: What is the maximum input voltage?
A: Continuous input is 30V DC. The module survives 50V for 1ms decaying pulses without damage.
Qo'shimcha Texnik Tavsiflar
- Kulrang
- Qora
- Oq
Skalyar (V/f)
Vektor
AC quvvatli
Sotib olish bo‘yicha qo‘llanma
- Buyurtma berishdan oldin aniq model, qism raqami va texnik xususiyatlarni tasdiqlang.
- Joriy mashinalaringiz yoki boshqaruv tizimlaringiz bilan mosligini ta’minlang.
- Texnik yordam uchun sale@etowonauto.com manzili yoki +8617859788089 raqamiga murojaat qiling.
- Yetkazib berish variantlari, yetkazib berish muddati va jo‘natish talablarini ko‘rib chiqing.
- O‘rnatish paytida ishlab chiqaruvchi ko‘rsatmalariga va eng yaxshi amaliyotlarga rioya qiling.
Yuborish va Qaytarish
Omborda mavjud bo‘lgan mahsulotlar odatda shu ish kuni jo‘natiladi. Hozirda omborda mavjud bo‘lmagan mahsulotlar uchun jo‘natish vaqti mavjudlikka qarab o‘zgarishi mumkin. Xalqaro yetkazib berish mavjud bo‘lib, yetkazib berish xarajatlari manzil, vazn va tashuvchi tanloviga ko‘ra hisoblanadi.
Qaytishlar qabul qilingan kundan boshlab 30 kun ichida amalga oshiriladi, agar mahsulotlar ishlatilmagan va asl holatda bo‘lsa. Qaytish xarajatlari mijoz zimmasida bo‘ladi. Iltimos, har qanday mahsulotni qaytarishdan oldin qaytish ruxsatini olish uchun biz bilan bog‘laning.
Batafsil ma’lumot uchun iltimos, Yetkazib berish va Qaytarish Siyosatini ko‘rib chiqing.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Tez yetkazib berish
Dunyoda tez yetkazib berish uchun original sanoat avtomatlashtirish qismlari mavjud.
-
Oson qaytarish
Ishonchli sotuvdan keyingi himoya uchun 12 oylik kafolat bilan 30 kunlik qaytarish qo'llab-quvvatlashi.
-
24/7 qo‘llab-quvvatlash
Barqaror va samarali ish faoliyatini ta'minlash uchun javobgar professional yordam.
-
Haqiqiy va Asl
100% haqiqiy, ishonchli sanoat avtomatlashtirish ishlab chiqaruvchilaridan to‘g‘ridan-to‘g‘ri olingan.
Texnik va Xarid Qollanmasi
-
Nima uchun PLC signal aralashuvi 61% to‘xtatishlarga sabab bo‘ladi?
Og‘ir yuk liniyalari EMI va yuk zarbalari tufayli yig‘ish liniyalariga nisbatan 3,2 barobar ko‘proq boshqaruv xatolar...
-
Bulut Avtomatizatsiyasining Tasdiqlangan ROIsi Nima?
Global ishlab chiqaruvchilar tarqalgan joylar va cheklangan texnik xizmat ko‘rsatish xodimlariga duch kelishadi. Ushb...
-
Sizning Kichik va O‘rta Biznes Jarayonlaringiz Zavodi Sanoat Avtomatizatsiyasi uchun Ortikcha To‘layaptimi?
Ushbu maqola kichik va o‘rta korxonalar jarayon fabrikalari uchun ortiqcha xarajat qilmasdan to‘g‘ri o‘lchamdagi DCS ...
-
Nima uchun CPU zaxirasi bo‘lishiga qaramay, 420 000 dollarlik to‘xtash yuz berdi?
Ushbu maqola 15 yillik maydonda sinovdan o'tgan dalillarni taqdim etadi, ular qisman DCS zaxirasi mavjud bo‘lsa ham, ...
-
How Does Emerson Edge Control Cut Cloud Dependency by 60%?
Emerson Edge Control Terminal processes OT data on-site, reducing latency to under 20ms and filtering 60% redundant d...
-
Low-Cost Brownfield Automation: Zero Downtime Possible?
This article shows how brownfield plants modernize legacy PLC and DCS systems using protocol gateways and edge termin...
