Evinizi, akıllı aydınlatmadan ses kontrollü cihazlara kadar hayatı daha kolay, güvenli ve bağlantılı hale getirmek için tasarlanmış en yeni çoklu elektronik çözümlerle dönüştürün. Arızaları önlemek ve çalışma süresini maksimize etmek için gerçek zamanlı titreşim ve makine durumu izleme sunan Bently Nevada 3500 İzleme Sistemi ile operasyonlarınızı optimize edin.
SKU:V18345-1010120001
TZIDC Positioner Single Acting | V18345-1010120001 ABB
Manufacturer: ABB
Product No.: V18345-1010120001
Product Type: Valve Positioner Module
Product Origin: Sweden
Payment:T/T, Western Union
Weight: 1700g
Shipping port: Xiamen
Warranty: 12 months
Paylaş
- Hızlı Teslimat
- 7/24 Destek
- Kalite Güvencesi
Açıklama
Product Overview
The V18345-1010120001 is a TZIDC electro-pneumatic positioner from ABB, designed for precise valve control on linear and rotary actuators. Features 4–20 mA two-wire input, HART communication, and single-acting fail-safe output. Aluminum housing with IP65/NEMA 4X protection. Weight: 1.7 kg.
Technical Configuration
Control Characteristics
Signal 4–20 mA corresponds to actuator position 0–100%, freely selectable for split-range operation (min range 20% / 3.2 mA). Characteristic curve: linear, equal percentage 1:25/1:50 or 25:1/50:1, freely configurable with 20 reference points. Travel limit adjustable to 20% minimum.
Technical Specifications
| Parameter | Specification |
|---|---|
| Part Number | V18345-1010120001 |
| Manufacturer | ABB |
| Type | TZIDC Electro-Pneumatic Positioner |
| Input Signal | 4–20 mA (two-wire), split-range selectable |
| Communication | HART, LKS local connector |
| Output / Safe Position | Single acting, fail safe |
| Supply Pressure | 1.4–6 bar (20–90 psi) |
| Air Consumption | <0.03 kg/h / 0.015 scfm |
| Housing Material | Aluminum, varnished, RAL 9005 |
| Protection Class | IP65 / NEMA 4X |
| Pneumatic Connections | G 1/4 or 1/4-18 NPT |
| Electrical Connections | 2 tap holes 1/2-14 NPT or M20 x 1.5 |
| Screw Terminals | Max 1.0 mm² (options) / 2.5 mm² (analog signal) |
| Digital Input | 0–5 V DC (logical 0), 11–30 V DC (logical 1) |
| Digital Output | 5–11 V DC (NAMUR DIN 19234) |
| Ambient Temperature | -40°C to +85°C (operation/storage/transport) |
| Humidity (Operational) | 95% annual average, condensation permissible |
| Humidity (Transport/Storage) | 75% annual average, non-condensing |
| Characteristic Curve | Linear, equal percentage, freely configurable (20 points) |
| Travel Limit | 0–100%, min 20% |
| Shut-off Function | Separately settable per end position |
| Travel Time Prolongation | Settable per direction |
| Weight | 1.7 kg |
Installation & Maintenance
Mounting
Mount to linear actuators per DIN/IEC 534/NAMUR or rotary actuators per VDI/VDE 3845. Integral mounting ready. Do not expose screw terminals to strain.
Air Supply
Use instrument air free of oil, water, and dust. Supply pressure 1.4–6 bar (20–90 psi). Do not exceed actuator max operating pressure. Air consumption <0.03 kg/h independent of supply pressure.
Electrical Connection
Connect 4–20 mA two-wire signal. Cable entry: 2 tap holes 1/2-14 NPT or M20 x 1.5 (one with cable gland, one with pipe plug). HART communication via signal line.
Engineering Advantages
Precise Valve Control
Freely configurable characteristic curves with 20 reference points. Split-range operation down to 20% (3.2 mA). Separate shut-off function and travel time prolongation per direction for precise process control.
Robust Environmental Protection
IP65/NEMA 4X aluminum housing with electrostatic epoxy varnish resists corrosion. Operates from -40°C to +85°C with 95% humidity (condensation permissible). Suitable for demanding industrial environments.
Flexible Configuration
Single-acting fail-safe output ensures safe valve position on power loss. HART communication enables remote diagnostics. Travel limit adjustable within 0–100% (minimum 20%) for application flexibility.
Technical FAQs
Q1: What is the supply pressure range for this positioner?
A1: 1.4–6 bar (20–90 psi). Do not exceed the maximum operating pressure of the actuator.
Q2: What is the fail-safe behavior on electrical power failure?
A2: The 1 suffix indicates single-acting, fail-safe output. The actuator moves to its safe position on loss of electrical power.
Q3: What ambient temperature range does this positioner support?
A3: -40°C to +85°C for operation, storage, and transport. When using proximity switches SJ2-S1N (NO), the range is -25°C to +85°C.
Ek Özellikler
- Gümüş
Skaler (V/f)
Vektör
AC ile çalışan
Satın Alma Rehberi
- Sipariş vermeden önce kesin model, parça numarası ve teknik özellikleri doğrulayın.
- Mevcut makine veya kontrol sistemlerinizle uyumluluğu kontrol edin.
- Teknik destek için sale@etowonauto.com adresinden veya +8617859788089 numarasından iletişime geçin.
- Teslimat seçeneklerini, teslim sürelerini ve nakliye gereksinimlerini inceleyin.
- Kurulum sırasında üretici talimatlarını ve en iyi uygulamaları takip edin.
Gönderim ve İade
Stokta bulunan ürünler genellikle aynı iş günü içinde gönderilir. Şu anda stokta olmayan ürünler için gönderim süreleri, ürünün bulunabilirliğine göre değişiklik gösterebilir. Uluslararası gönderim mevcuttur ve gönderim ücretleri varış yeri, ağırlık ve taşıyıcı seçimine göre hesaplanır.
Ürünler kullanılmamış ve orijinal durumda olmak koşuluyla, teslim alındıktan sonraki 30 gün içinde iade kabul edilir. İade gönderim ücretleri müşteriye aittir. Lütfen herhangi bir ürünü iade etmeden önce iade onayı almak için bizimle iletişime geçin.
Daha fazla bilgi için lütfen Gönderim ve İade Politikamızı inceleyin.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Hızlı Gönderim
Orijinal endüstriyel otomasyon parçaları, dünya çapında hızlı gönderim için mevcuttur.
-
Kolay İade
Güvenilir satış sonrası koruma için 12 aylık garanti ile 30 gün iade desteği.
-
7/24 destek
Kararlı ve verimli operasyonların sürdürülmesine yardımcı olmak için duyarlı profesyonel destek.
-
Orijinal ve Gerçek
%100 orijinal, güvenilir endüstriyel otomasyon üreticilerinden doğrudan temin edilmiştir.
Teknik ve Satın Alma Rehberi
-
How Can You Tune GE RX3i and RX7i Ethernet for Heavy Industry?
Intermittent Ethernet timeouts on GE RX3i and RX7i controllers are among the hardest faults in heavy process plants, ...
-
Why Does FCS Redundancy Not Protect Your HIS Configuration?
This article examines the operational risks of Yokogawa CENTUM VP HIS lockups and explains why FCS controller re...
-
How Does 1756 Analog I/O Calibration Drift Affect PLC Accuracy?
This article examines calibration drift in Allen-Bradley ControlLogix 1756 analog I/O modules, presenting quanti...
-
Why Do 31% of ABB 800xA S800 IO Hot Swaps Fail in DCS Systems?
ABB 800xA S800 hot swap failures rarely stem from defective hardware. Field data from 142 card replacement jobs shows...
-
How Do You Diagnose Degraded MTL Surge Protection Devices?
This article presents field-proven diagnostic checks, aging benchmarks, and installation rules for MTL surge pro...
-
How Can You Stop Nuisance Trips on Bently Nevada TSI Systems?
Nuisance trips on Bently Nevada TSI racks cost power and oil & gas plants $18,000 to $45,000 per event and occur ...