Evinizi, akıllı aydınlatmadan ses kontrollü cihazlara kadar hayatı daha kolay, güvenli ve bağlantılı hale getirmek için tasarlanmış en yeni çoklu elektronik çözümlerle dönüştürün. Arızaları önlemek ve çalışma süresini maksimize etmek için gerçek zamanlı titreşim ve makine durumu izleme sunan Bently Nevada 3500 İzleme Sistemi ile operasyonlarınızı optimize edin.
SKU:SPAJ142C-AA
SPAJ142C-AA ABB Overcurrent Earth-Fault Relay 0.2-1.0A 50/60Hz
Manufacturer: ABB
Product No.: SPAJ142C-AA
Product Type: Relay Module
Product Origin: Sweden
Payment:T/T, Western Union
Weight: 500g
Shipping port: Xiamen
Warranty: 12 months
Paylaş
- Hızlı Teslimat
- 7/24 Destek
- Kalite Güvencesi
Açıklama
Product Overview
The SPAJ142C-AA is a combined overcurrent and earth-fault protection relay manufactured by ABB. Operating across a wide auxiliary supply voltage of 110-240 V AC/DC (50/60 Hz), this compact protective relay features an adjustable current setting range of 0.2 to 1.0 A and adjustable time delay settings from 0.1 s to 10 s. Measuring 45 mm x 90 mm x 100 mm with a net weight of 1.10 lbs (0.5 kg), it incorporates flexible earth-fault sensitivity settings from 10 to 300 mA to ensure selective isolation of power distribution faults.
Core Technical Advantages
- Dual Protection Capabilities: Combines phase overcurrent and sensitive earth-fault detection within a single compact module.
- Universal Power Supply: Accepts a wide auxiliary operating voltage range from 110 to 240 V AC/DC for versatile panel integration.
- Adjustable Timing & Sensitivity: Offers programmable time delays (0.1 to 10 s) and earth-fault thresholds (10 to 300 mA) for precise trip coordination.
- High Reliability: Engineered for an MTBF exceeding 100,000 hours in harsh industrial environments (-20 °C to +60 °C).
Technical Specifications
| Parameter | Specification Details |
|---|---|
| Manufacturer & Brand | ABB |
| Product Model / Type | SPAJ142C-AA (Overcurrent and Earth-Fault Relay) |
| Rated Operating Voltage | 110 - 240 V AC/DC (50 / 60 Hz) |
| Current Setting Range | 0.2 - 1.0 A |
| Time Delay Settings | 0.1 s to 10 s (Adjustable) |
| Earth-Fault Sensitivity | 10 to 300 mA (Adjustable) |
| Output Contact Configuration | 1 NO / 1 NC (Changeover Contact) |
| Physical Dimensions & Weight | 45 mm x 90 mm x 100 mm; Net Mass: 1.10 lbs (0.5 kg) |
| Protection & Operating Temp | IP20 Protection Level; -20 °C to +60 °C (-4 °F to +140 °F) |
| Reliability Standard | MTBF > 100,000 Hours |
Industrial Solutions
- Substation Feeder Protection: Protects radial distribution feeders against phase overcurrents and ground leakage faults.
- Industrial Motor Protection: Monitors incoming feeder lines for large high-voltage induction motors to prevent thermal damage.
- Transformer Earth-Fault Monitoring: Serves as secondary backup protection for power transformers in distribution switchgear networks.
Wiring & Installation
Auxiliary Power & Circuit Isolation
Isolate main distribution breakers and verify de-energization of secondary CT circuits before mounting or wiring the SPAJ142C-AA relay.
Panel Mounting
Mount the 0.5 kg relay securely inside an IP20 or higher protective control cabinet, preserving space around its 45 x 90 x 100 mm frame for wiring access and heat dissipation across -20 °C to +60 °C operating temperatures.
CT & Contact Connections
Wire current transformer (CT) secondary leads to the overcurrent and earth-fault input terminals, ensuring 1 NO/1 NC changeover trip contacts are wired correctly to the circuit breaker trip coil.
Commissioning Test
Apply 110-240 V AC/DC auxiliary power, adjust pickup thresholds (0.2-1.0 A) and time delays (0.1-10 s), and execute secondary injection testing prior to placing in service.
Engineering Advantages
- Compact Enclosure: Space-saving 45x90x100 mm footprint permits high-density panel layout in retrofit switchboards.
- Wide Operational Margin: Robust IP20 housing and extended MTBF (>100,000 hours) minimize maintenance intervention.
- Versatile Trip Interfacing: Changeover output contacts ensure direct compatibility with a wide range of trip circuit topologies.
Technical FAQs
Q1: What are the current setting range and earth-fault sensitivity for SPAJ142C-AA?
A1: Overcurrent setting ranges from 0.2 to 1.0 A, while earth-fault sensitivity is adjustable between 10 and 300 mA.
Q2: What is the auxiliary operating voltage for this ABB relay?
A2: It operates on a rated voltage of 110-240 V AC/DC at 50/60 Hz.
Q3: What are the physical dimensions and component weight?
A3: Measures 45 mm x 90 mm x 100 mm with a net weight of 1.10 lbs (0.5 kg).
Ek Özellikler
- Gri
Skaler (V/f)
Vektör
AC ile çalışan
Satın Alma Rehberi
- Sipariş vermeden önce kesin model, parça numarası ve teknik özellikleri doğrulayın.
- Mevcut makine veya kontrol sistemlerinizle uyumluluğu kontrol edin.
- Teknik destek için sale@etowonauto.com adresinden veya +8617859788089 numarasından iletişime geçin.
- Teslimat seçeneklerini, teslim sürelerini ve nakliye gereksinimlerini inceleyin.
- Kurulum sırasında üretici talimatlarını ve en iyi uygulamaları takip edin.
Gönderim ve İade
Stokta bulunan ürünler genellikle aynı iş günü içinde gönderilir. Şu anda stokta olmayan ürünler için gönderim süreleri, ürünün bulunabilirliğine göre değişiklik gösterebilir. Uluslararası gönderim mevcuttur ve gönderim ücretleri varış yeri, ağırlık ve taşıyıcı seçimine göre hesaplanır.
Ürünler kullanılmamış ve orijinal durumda olmak koşuluyla, teslim alındıktan sonraki 30 gün içinde iade kabul edilir. İade gönderim ücretleri müşteriye aittir. Lütfen herhangi bir ürünü iade etmeden önce iade onayı almak için bizimle iletişime geçin.
Daha fazla bilgi için lütfen Gönderim ve İade Politikamızı inceleyin.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Hızlı Gönderim
Orijinal endüstriyel otomasyon parçaları, dünya çapında hızlı gönderim için mevcuttur.
-
Kolay İade
Güvenilir satış sonrası koruma için 12 aylık garanti ile 30 gün iade desteği.
-
7/24 destek
Kararlı ve verimli operasyonların sürdürülmesine yardımcı olmak için duyarlı profesyonel destek.
-
Orijinal ve Gerçek
%100 orijinal, güvenilir endüstriyel otomasyon üreticilerinden doğrudan temin edilmiştir.
Teknik ve Satın Alma Rehberi
-
How Does 1756 Analog I/O Calibration Drift Affect PLC Accuracy?
This article examines calibration drift in Allen-Bradley ControlLogix 1756 analog I/O modules, presenting quanti...
-
Why Do 31% of ABB 800xA S800 IO Hot Swaps Fail in DCS Systems?
ABB 800xA S800 hot swap failures rarely stem from defective hardware. Field data from 142 card replacement jobs shows...
-
How Do You Diagnose Degraded MTL Surge Protection Devices?
This article presents field-proven diagnostic checks, aging benchmarks, and installation rules for MTL surge pro...
-
How Can You Stop Nuisance Trips on Bently Nevada TSI Systems?
Nuisance trips on Bently Nevada TSI racks cost power and oil & gas plants $18,000 to $45,000 per event and occur ...
-
When Should You Replace a Yokogawa Analog IO Card?
This article breaks down Yokogawa analog AI/AO card calibration tolerances, drift aging benchmarks, and formal replac...
-
What Performance Gains Does S7-1500 Offer Over Legacy S7 PLCs?
Legacy Siemens S7-300 and S7-400 PLCs face spare-part shortages, rising failure rates and limited network capability,...