Evinizi, akıllı aydınlatmadan ses kontrollü cihazlara kadar hayatı daha kolay, güvenli ve bağlantılı hale getirmek için tasarlanmış en yeni çoklu elektronik çözümlerle dönüştürün. Arızaları önlemek ve çalışma süresini maksimize etmek için gerçek zamanlı titreşim ve makine durumu izleme sunan Bently Nevada 3500 İzleme Sistemi ile operasyonlarınızı optimize edin.
SKU:IC693CBL304
IC693CBL304 GE Series 90-30 PCM300 Splitter Cable 1ft
Manufacturer: General Electric
Product No.: IC693CBL304
Product Type: Expansion Cable
Product Origin: USA
Payment:T/T, Western Union
Weight: 140g
Shipping port: Xiamen
Warranty: 12 months
Paylaş
- Hızlı Teslimat
- 7/24 Destek
- Kalite Güvencesi
Açıklama
Product Overview
The GE Fanuc IC693CBL304 is a specialized, highly compact 1-foot (0.3-meter) port expansion "Wye" cable engineered exclusively for the Series 90-30 Programmable Coprocessor Module (IC693PCM300). This ultra-lightweight adapter, weighing only 0.14 kg (0.31 lbs), serves as a signal splitter, separating combined RS-232 and RS-485 communications from a single physical port on the PCM host module into two distinct, isolated connections. Equipped with a space-saving right-angle male connector on the module side and dual-female connectors on the output end, it delivers seamless signal routing without adding physical strain or bulky weight to your PLC rack assembly.
Key Advantages
- Dual-Protocol Separation: Effortlessly splits combined lines to deliver dedicated RS-232 signals on one leg and RS-485 signals on the other, allowing simultaneous dual-port operation.
- Right-Angle & Compact Design: The module-end connector features a right-angle profile, and at a minimal weight of just 0.14 kg, it fits neatly into tight control panels and shallow enclosures without straining delicate ports.
- Continuous Shielding: Encased in high-quality, continuous electrical shielding to block electromagnetic interference (EMI) and preserve communication speeds in noisy industrial environments.
- 90/70 to 90/30 Compatibility: Standardizes physical connections, making the Series 90/70 PCM interface fully compatible with Series 90/30 PCM module hardware.
Technical Specifications
| Model Number | IC693CBL304 |
| Brand / Series | GE Fanuc / Series 90-30 |
| Cable Type | Port Expansion (Wye / Splitter) Cable |
| Module Compatibility | IC693PCM300 (Programmable Coprocessor Module) |
| Cable Length | 1 foot (approx. 30 cm) |
| Connector 1 (Module End) | Right-Angle Male Connector |
| Connector 2 (Device End) | Dual-Female Connectors (Port 1 and Port 2) |
| Shielding Type | Continuous high-coverage shield |
| Net Weight | 0.14 kg (0.31 lbs) |
| Max Units Per Module | One Wye cable per PCM module |
| Lifecycle Status | Discontinued / Obsolete (Available as legacy support) |
Quick Installation & Safety Tips
- Equal Potential Grounding: Ensure that the IC693CBL304 cable shielding, the host PCM module, and the PLC baseplate are all tied to the same electrical ground potential. Caution: Ground loops or mismatched voltage potentials can permanently damage connected programming terminals or internal module electronics.
- Align Right-Angle Connector Carefully: When plugging the right-angle male end into the PCM module, line up the pins smoothly before applying pressure to avoid bending the pins in the module's communication port.
- Port Identification: The dual-female end splits the signals into Port 1 and Port 2. Refer to your system program configuration to ensure the RS-232 serial link and RS-485 serial link are mapped and connected to the correct corresponding output ports.
Technical FAQs
Q1: Why does this cable split into two connections from a single physical port?
A1: The IC693PCM300 module consolidates both RS-232 and RS-485 pinouts into a single high-density connector to save space. The IC693CBL304 Wye cable acts as a hardware splitter, separating these signal lines into two independent physical ports (Port 1 and Port 2) to allow simultaneous connections.
Q2: What happens if the cable and baseplate are not grounded at the same potential?
A2: Failure to ground the system at equal ground potential will lead to stray currents flowing through the communications line. This can cause communication faults, signal corruption, or catastrophic hardware damage to the PCM module, the cable, and connected programmer devices.
Q3: Is the IC693CBL304 cable included when I buy the IC693PCM300 module?
A3: Yes, this Wye cable was originally supplied standard inside the box with the IC693PCM300 module. However, because it can wear out or get lost during field servicing, it is also available as an individual replacement accessory.
Ek Özellikler
Skaler (V/f)
Vektör
AC ile çalışan
Satın Alma Rehberi
- Sipariş vermeden önce kesin model, parça numarası ve teknik özellikleri doğrulayın.
- Mevcut makine veya kontrol sistemlerinizle uyumluluğu kontrol edin.
- Teknik destek için sale@etowonauto.com adresinden veya +8617859788089 numarasından iletişime geçin.
- Teslimat seçeneklerini, teslim sürelerini ve nakliye gereksinimlerini inceleyin.
- Kurulum sırasında üretici talimatlarını ve en iyi uygulamaları takip edin.
Gönderim ve İade
Stokta bulunan ürünler genellikle aynı iş günü içinde gönderilir. Şu anda stokta olmayan ürünler için gönderim süreleri, ürünün bulunabilirliğine göre değişiklik gösterebilir. Uluslararası gönderim mevcuttur ve gönderim ücretleri varış yeri, ağırlık ve taşıyıcı seçimine göre hesaplanır.
Ürünler kullanılmamış ve orijinal durumda olmak koşuluyla, teslim alındıktan sonraki 30 gün içinde iade kabul edilir. İade gönderim ücretleri müşteriye aittir. Lütfen herhangi bir ürünü iade etmeden önce iade onayı almak için bizimle iletişime geçin.
Daha fazla bilgi için lütfen Gönderim ve İade Politikamızı inceleyin.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Hızlı Gönderim
Orijinal endüstriyel otomasyon parçaları, dünya çapında hızlı gönderim için mevcuttur.
-
Kolay İade
Güvenilir satış sonrası koruma için 12 aylık garanti ile 30 gün iade desteği.
-
7/24 destek
Kararlı ve verimli operasyonların sürdürülmesine yardımcı olmak için duyarlı profesyonel destek.
-
Orijinal ve Gerçek
%100 orijinal, güvenilir endüstriyel otomasyon üreticilerinden doğrudan temin edilmiştir.
Teknik ve Satın Alma Rehberi
-
How Does GE Proficy HMI Design Cut Operator Response Time?
This article explains how field-proven GE Proficy HMI design principles, including tiered navigation, ISA 101 alarm c...
-
How Does ABB Cabinet FAT Cut Site Commissioning Risk?
This article explains how standardized ABB control cabinet assembly and factory acceptance testing reduce industrial ...
-
How Does Bently Nevada Balancing Stabilize Turbo Machinery?
This article explains how Bently Nevada TSI instruments enable practical field dynamic balancing for turbo machinery....
-
What Makes GE Historian Ideal for Industrial Time-Series Storage?
GE Historian delivers optimized long-term industrial time-series storage for control systems. It compresses OT data b...
-
How Do You Calibrate Honeywell Transmitters in Hazardous Areas?
This article explains how to calibrate Honeywell field instruments safely in hazardous areas, covering pre-calibratio...
-
How to Cut Bently Nevada TSI False Alarms on Compressor Skids?
This article explains how Bently Nevada TSI network layout affects compressor skid vibration monitoring reliability. ...