Evinizi, akıllı aydınlatmadan ses kontrollü cihazlara kadar hayatı daha kolay, güvenli ve bağlantılı hale getirmek için tasarlanmış en yeni çoklu elektronik çözümlerle dönüştürün. Arızaları önlemek ve çalışma süresini maksimize etmek için gerçek zamanlı titreşim ve makine durumu izleme sunan Bently Nevada 3500 İzleme Sistemi ile operasyonlarınızı optimize edin.
SKU:330905-00-08-05-12-00
Bently Nevada | 3300 NSv Probe | 330905-00-08-05-12-00
Manufacturer: Bently Nevada
Product No.: 330905-00-08-05-12-00
Product Type: Proximity Probe
Product Origin: USA
Payment:T/T, Western Union
Weight: 450g
Shipping port: Xiamen
Warranty: 12 months
Paylaş
- Hızlı Teslimat
- 7/24 Destek
- Kalite Güvencesi
Açıklama
Product Overview
The Bently Nevada 330905-00-08-05-12-00 is a 3300 NSv proximity probe with an M10×1 thread, 80 mm case length, and 0.5 m miniature coaxial ClickLoc cable with FluidLoc construction. It measures shaft vibration and axial position on turbines, compressors, and pumps with a 1.5 mm linear range and 7.87 V/mm scale factor. Each probe weighs approximately 0.45 kg, keeping bracket loading low. The short 80 mm case fits tight mounting spaces, while the FluidLoc cable resists moisture ingress in wet process compressor service.
Technical Configuration
Model Code Breakdown
The 330905 code defines the NSv probe family. The -00- option sets a 0 mm unthreaded length. The -08- option sets an 80 mm overall case length. The 05 option sets a 0.5 m total length. The 12 option specifies a miniature coaxial ClickLoc connector with FluidLoc cable. The -00 agency approval option means no certification required.
Core Hardware
The probe uses a polyphenylene sulfide tip and AISI 304 stainless steel case. The 75 Ω coaxial FEP cable with FluidLoc construction carries the signal to the ClickLoc connector. A Viton O-ring seals differential pressure between the probe tip and case. The probe is mechanically and electrically interchangeable with the earlier 3300 RAM probe and extension cable.
Technical Specifications
| Parameter | Specification |
| Linear Range | 1.5 mm (60 mils), 0.25 to 1.75 mm |
| Recommended Gap | 1.0 mm (40 mils) |
| Scale Factor | 7.87 V/mm (200 mV/mil) +12.5%/-20% |
| Deviation from Best Fit | Less than ±0.06 mm (±2.3 mils) |
| Frequency Response | 0 to 10 kHz, +0/-3 dB typical |
| Probe DC Resistance | 4.0 ± 0.5 ohms at 0.5 m |
| Operating Temperature | -52°C to +177°C (-62°F to +351°F) |
| Minimum Bend Radius | 25.4 mm (1.0 in) |
| Target Size | Min 8.9 mm, recommended 13 mm |
| Thread | M10×1, 15 mm max engagement |
| Probe Case Torque | 7.5 N·m recommended, 22.6 N·m max |
| Field Wiring | 0.2 to 1.5 mm², max 305 m |
| Weight | Approx. 0.45 kg |
Installation Guide
Set the gap at 1.0 mm (40 mils) using a feeler gauge or the -1 to -13 Vdc output reading. Keep the minimum bend radius at 25.4 mm to avoid cable damage. Apply 7.5 N·m torque to the M10×1 probe case, never exceeding 22.6 N·m. Use three-conductor shielded triad cable for field wiring and keep total length under 305 meters. The 80 mm case suits shallow mounting bosses where longer probes will not fit. Confirm the Viton O-ring seats correctly before pressurizing the machine.
Engineering Advantages
The 80 mm case fits tight mounting locations that reject standard-length probes, giving engineers layout flexibility. The FluidLoc cable blocks moisture wicking along the cable core, a common failure point in washdown and humid areas. The NSv probe delivers higher chemical resistance than the 3300 RAM probe, extending service life in process compressor environments. The probe and extension cable interchange directly with existing 3300 RAM installations, cutting upgrade downtime. The lightweight 0.45 kg body reduces bracket stress.
Technical FAQs
Q1: When should I choose the 80 mm case over the 130 mm version?
A1: Choose the 80 mm case when the mounting boss is short or space behind the probe is limited. Confirm the probe tip still reaches the recommended 1.0 mm gap from the target before ordering.
Q2: How do I set the probe gap?
A2: Target 1.0 mm (40 mils), which corresponds to roughly -10 Vdc. Confirm the reading falls within the -1 to -13 Vdc linear range before locking the probe.
Q3: What is the difference between standard cable and FluidLoc cable?
A3: FluidLoc construction seals the cable core against fluid migration. Choose it for wet, humid, or washdown locations where standard cable may allow moisture to travel toward the connector.
Ek Özellikler
Skaler (V/f)
Vektör
AC ile çalışan
Satın Alma Rehberi
- Sipariş vermeden önce kesin model, parça numarası ve teknik özellikleri doğrulayın.
- Mevcut makine veya kontrol sistemlerinizle uyumluluğu kontrol edin.
- Teknik destek için sale@etowonauto.com adresinden veya +8617859788089 numarasından iletişime geçin.
- Teslimat seçeneklerini, teslim sürelerini ve nakliye gereksinimlerini inceleyin.
- Kurulum sırasında üretici talimatlarını ve en iyi uygulamaları takip edin.
Gönderim ve İade
Stokta bulunan ürünler genellikle aynı iş günü içinde gönderilir. Şu anda stokta olmayan ürünler için gönderim süreleri, ürünün bulunabilirliğine göre değişiklik gösterebilir. Uluslararası gönderim mevcuttur ve gönderim ücretleri varış yeri, ağırlık ve taşıyıcı seçimine göre hesaplanır.
Ürünler kullanılmamış ve orijinal durumda olmak koşuluyla, teslim alındıktan sonraki 30 gün içinde iade kabul edilir. İade gönderim ücretleri müşteriye aittir. Lütfen herhangi bir ürünü iade etmeden önce iade onayı almak için bizimle iletişime geçin.
Daha fazla bilgi için lütfen Gönderim ve İade Politikamızı inceleyin.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Hızlı Gönderim
Orijinal endüstriyel otomasyon parçaları, dünya çapında hızlı gönderim için mevcuttur.
-
Kolay İade
Güvenilir satış sonrası koruma için 12 aylık garanti ile 30 gün iade desteği.
-
7/24 destek
Kararlı ve verimli operasyonların sürdürülmesine yardımcı olmak için duyarlı profesyonel destek.
-
Orijinal ve Gerçek
%100 orijinal, güvenilir endüstriyel otomasyon üreticilerinden doğrudan temin edilmiştir.
Teknik ve Satın Alma Rehberi
-
How Does 1756 Analog I/O Calibration Drift Affect PLC Accuracy?
This article examines calibration drift in Allen-Bradley ControlLogix 1756 analog I/O modules, presenting quanti...
-
Why Do 31% of ABB 800xA S800 IO Hot Swaps Fail in DCS Systems?
ABB 800xA S800 hot swap failures rarely stem from defective hardware. Field data from 142 card replacement jobs shows...
-
How Do You Diagnose Degraded MTL Surge Protection Devices?
This article presents field-proven diagnostic checks, aging benchmarks, and installation rules for MTL surge pro...
-
How Can You Stop Nuisance Trips on Bently Nevada TSI Systems?
Nuisance trips on Bently Nevada TSI racks cost power and oil & gas plants $18,000 to $45,000 per event and occur ...
-
When Should You Replace a Yokogawa Analog IO Card?
This article breaks down Yokogawa analog AI/AO card calibration tolerances, drift aging benchmarks, and formal replac...
-
What Performance Gains Does S7-1500 Offer Over Legacy S7 PLCs?
Legacy Siemens S7-300 and S7-400 PLCs face spare-part shortages, rising failure rates and limited network capability,...