Transforme sua casa com as mais recentes soluções multi-eletrônicas, desde iluminação inteligente até dispositivos controlados por voz — tudo projetado para tornar a vida mais fácil, segura e conectada. Otimize suas operações com o Sistema de Monitoramento Bently Nevada 3500, que oferece monitoramento em tempo real de vibração e condição das máquinas para prevenir falhas e maximizar o tempo de atividade.
SKU:ATV71HC11N4D
Schneider Variable Speed Drive 215A | ATV71HC11N4D
Manufacturer: Schneider
Product No.: ATV71HC11N4D
Product Type: Variable Speed Drive
Product Origin: FR
Payment:T/T, Western Union
Weight: 90000g
Shipping port: Xiamen
Warranty: 12 months
Compartilhar
- Entrega Rápida
- Suporte 24 horas por dia, 7 dias por semana
- Garantia de Qualidade
Descrição
Schneider Electric ATV71HC11N4D Altivar 71 Variable Speed Drive
Schneider Electric ATV71HC11N4D | Altivar 71 variable speed drive for complex, high-power machines. Delivers 110 kW (150 HP) motor power with 215 A nominal output current at 380-480V three-phase supply. Integrated EMC filter and heat sink. Reinforced version without DC choke, designed for door mounting. Supports asynchronous and synchronous motors. Weight: 90 kg (198.4 lbs).
Technical Specifications
| Manufacturer | Schneider Electric |
| Part Number | ATV71HC11N4D |
| Product Line | Altivar 71 |
| Product Type | Variable Speed Drive |
| Motor Power | 110 kW (150 HP), 3-phase 380-480V |
| Supply Voltage | 380-480V (-15%/+10%), 3-phase |
| Supply Voltage Limits | 323-528V |
| Supply Frequency | 50-60 Hz ±5% (47.5-63 Hz) |
| Line Current (480V) | 163 A |
| Line Current (380V) | 202 A |
| Apparent Power | 133 kVA @ 380V |
| Nominal Output Current | 215 A @ 2.5 kHz |
| Maximum Transient Current | 323 A for 60 s; 355 A for 2 s |
| Output Frequency | 0.1-500 Hz |
| Nominal Switching Frequency | 2.5 kHz (adjustable 2.5-8 kHz) |
| Prospective Line Isc | 35 kA |
| EMC Filter | Integrated |
| Heat Sink | Yes |
| Variant | Reinforced version, without DC choke |
| Mounting Type | Door Mount |
| Control Methods | Sensorless Vector, Vector, V/f, Synchronous |
| Braking to Standstill | DC injection |
| Analog Inputs | 2 (AI1 ±10V, AI2 0-20mA/0-10V) |
| Analog Output | 1 (AO1 0-20mA/0-10V) |
| Discrete Inputs | 7 (LI1-LI5 programmable 24VDC, LI6 configurable, PWR safety) |
| Discrete Outputs | 2 relay (R1 NO/NC, R2 NO) |
| Communication | Modbus (2-wire RS485), CANopen |
| Transmission Rates (Modbus) | 4800, 9600, 19200, 38.4 kbps |
| Transmission Rates (CANopen) | 20 kbps to 1 Mbps |
| Speed Accuracy (Closed-Loop) | ±0.01% of nominal speed |
| Torque Accuracy (Closed-Loop) | ±5% |
| Transient Overtorque | 170% for 60 s; 220% for 2 s |
| Braking Torque (with resistor) | ≤150% |
| Insulation Resistance | >1 MOhm at 500V DC for 1 minute |
| Dielectric Strength | 3535V DC (earth to power); 5092V DC (control to power) |
| Protection Class | IP54 (lower), IP41 (upper), IP30 (front/sides), IP00 |
| Noise Level | 69.5 dB (86/188/EEC) |
| Operating Temperature | -10°C to +50°C (without derating) |
| Storage Temperature | -25°C to +70°C |
| Relative Humidity | 5-95% (non-condensing) |
| Operating Altitude | ≤1000 m without derating; 1000-3000 m with 1% derating per 100 m |
| Vibration Resistance | 0.6 gn (10-200 Hz); 1.5 mm peak-to-peak (3-10 Hz) |
| Shock Resistance | 7 gn, 11 ms (EN/IEC 60068-2-27) |
| Dimensions (H x W x D) | 1022 x 360 x 377 mm (40.2 x 14.2 x 14.8 in) |
| Net Weight | 90 kg (198.4 lbs) |
| Gross Weight | 121.56 kg (268.00 lbs) |
| Standards | EN/IEC 61800-3, EN/IEC 61800-5-1, UL Type 1 |
| Certifications | CE, UL, CSA, GOST, NOM 117, C-tick |
Additional Technical Parameters
| Maximum Motor Cable Length (Shielded) | 100 m (328.08 ft) |
| Maximum Motor Cable Length (Unshielded) | 200 m (656.2 ft) |
| Analog Input Sampling Time | 2 ms ±0.5 ms |
| Discrete Input Sampling Time | 2 ms ±0.5 ms |
| STO Response Time | ≤100 ms |
| Relay Output Response Time | 7 ms ±0.5 ms |
| Analog Input Linearity Error | ±0.15% of maximum value |
| Analog Output Linearity Error | ±0.2% |
| Relay Mechanical Life | 100,000 cycles |
| Minimum Switching Current | 3 mA at 24V DC |
Installation Notes
Mount vertically (±10°) using door-mount configuration. Connect 380-480V three-phase supply per local electrical codes. Observe terminal tightening torques: 0.6 N·m for control terminals, 24 N·m for motor terminals, 12 N·m for PA/PB, 41 N·m for PC/PO/PA/+. Maximum motor cable length is 100 m shielded or 200 m unshielded. Maintain operating temperature within -10°C to +50°C without derating. For altitudes above 1000 m, apply 1% current derating per 100 m. The D suffix indicates no DC choke and no graphic terminal. Ensure proper grounding and use the integrated EMC filter for electromagnetic compliance.
FAQs
Q1: What is the motor power rating of this drive?
A1: 110 kW (150 HP) at 380-480V three-phase supply.
Q2: What communication protocols are built in?
A2: Modbus (2-wire RS485) and CANopen.
Q3: What does the D suffix indicate?
A3: The drive is a reinforced version without a DC choke and without a remote graphic terminal.
Especificações Adicionais
Escalar (V/f)
Vetor
Alimentado por corrente alternada
Guia de Compra
- Confirme o modelo exato, número da peça e especificações antes de fazer o pedido.
- Garanta a compatibilidade com sua máquina ou sistemas de controle atuais.
- Entre em contato pelo sale@etowonauto.com ou pelo +8617859788089 para assistência técnica.
- Verifique as opções de entrega, prazos e requisitos de envio.
- Siga as instruções do fabricante e as melhores práticas durante a instalação.
Envio e Devolução
Itens em estoque geralmente são despachados no mesmo dia útil. Para produtos que não estão disponíveis no momento, os prazos de despacho podem variar conforme a disponibilidade. O envio internacional está disponível, e os custos de envio são calculados de acordo com o destino, peso e transportadora escolhida.
Devoluções são aceitas dentro de 30 dias após o recebimento, desde que os itens estejam sem uso e em condição original. Os custos de envio para devolução são de responsabilidade do cliente. Por favor, entre em contato conosco antes de devolver qualquer item para receber a autorização de devolução.
Para mais detalhes, por favor, consulte nossa Política de Envio e Devolução.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Envio Rápido
Peças originais de automação industrial disponíveis para envio rápido em todo o mundo.
-
Devoluções Fáceis
Suporte para devolução em 30 dias com garantia de 12 meses para proteção confiável pós-venda.
-
Suporte 24 horas por dia, 7 dias por semana
Suporte profissional responsivo para ajudar a manter operações estáveis e eficientes.
-
Autêntico e Original
100% autêntico, proveniente diretamente de fabricantes confiáveis de automação industrial.
Guia Técnico e de Compra
-
How Does the Bently Nevada 3500/42M Vibration Module Drift?
This technical guide examines the Bently Nevada 3500/42M vibration module within industrial automation architect...
-
What Causes IC694MDL Fault Codes in GE RX3i PLC Systems?
This guide explains GE RX3i IC694MDL discrete I/O fault codes, key electrical parameters, ESD and torque requirements...
-
What CFC Rules Cut PCS7 Batch Abort Rates Fast?
This article presents enforceable CFC programming governance rules for Siemens PCS7 DCS batch plants, covering b...
-
What Makes the 1769-L3ER Ideal for Compact Skid Automation?
This guide explains how the Allen-Bradley 1769 CompactLogix L3ER bridges the gap between micro PLCs and large DC...
-
Why Do SIL3 Safety Interlocks Still Trip in Industrial Plants?
This article reviews Honeywell Safety Manager SIL3 SIS architecture, wiring and cabinet installation rules, PFDa...
-
How Does Poor Grounding Cause 4-20mA Signal Drift?
This guide explains how MTL signal isolators fail through distortion, drift and EMI in PLC and DCS loops, then d...