Pular para o conteúdo
Peças de automação, fornecimento mundial
Pular para as informações do produto
1 de 3

SKU:MTL5021

MTL5021 Hazardous Area Driver - MTL Instruments

Em estoque (25 unidades), pronto para envio
  • Manufacturer: MTL

  • Product No.: MTL5021

  • Product Type: Control Driver

  • Product Origin: USA

  • Payment:T/T, Western Union

  • Weight: 110g

  • Shipping port: Xiamen

  • Warranty: 12 months

Política de Devolução em 30 Dias · Garantia de 12 Meses
  • Entrega Rápida
  • Suporte 24 horas por dia, 7 dias por semana
  • Garantia de Qualidade

Descrição

MTL5021 Hazardous Area Control Driver

The MTL5021 from MTL Instruments provides safe control of hazardous area devices from safe area switches. This single-channel interface drives intrinsically safe low-power loads and non-energy-storing apparatus like LEDs. Its flexible input/output isolation allows control switch connection on either side of the 24V DC supply circuit.

Key Technical Specifications

  • Brand: MTL Instruments
  • Model: MTL5021
  • Product Type: Hazardous Area Control Driver
  • Channels: One channel
  • Output Current: 45mA maximum
  • Input Voltage: 20 to 35V DC
  • Status Indicator: Yellow LED for operational status

Hazardous Area Certification

  • Load Location: Zone 0, IIC, T4-T6 hazardous area
  • Division Rating: Division 1, Group A hazardous location
  • The MTL5021 maintains intrinsic safety for connected loads
  • It enables safe control of devices in explosive atmospheres

Output Performance

  • Minimum Output Voltage: 12.85V at 45mA
  • Maximum Output Voltage: 24V from 170Ω
  • Current Limit: 45mA maximum for safety
  • Output Terminals: Terminal 1 (Output –ve), Terminal 2 (Output +ve)
  • Suitable for intrinsically safe low-power loads and LED indicators

Power Requirements

  • Input Voltage: 20 to 35V DC operating range
  • Current Consumption: 90mA at 24V with 45mA output
  • Power Dissipation: 1.4W at 24V typical
  • Maximum Dissipation: 1.8W at 35V
  • Supply Terminals: Terminal 11 (Supply –ve), Terminal 12 (Supply +ve)

Terminal Configuration

  • Output: Terminal 1 (Output –ve), Terminal 2 (Output +ve)
  • Earth Leakage: Terminal 3 for detection capability
  • Power Supply: Terminal 11 (Supply –ve), Terminal 12 (Supply +ve)
  • Flexible wiring allows control switch on either supply side
  • Clear terminal identification simplifies installation

Safety Parameters

  • Safety Voltage: 25V maximum
  • Internal Resistance: 170Ω
  • Safety Current: 147mA maximum
  • Isolation Voltage: Um = 250V rms or DC
  • Comprehensive protection for hazardous area operation

Frequently Asked Questions

  • What type of loads can the MTL5021 drive?
    It drives intrinsically safe low-power loads and non-energy-storing apparatus like LEDs.
  • What is the maximum output current?
    The output is current limited to 45mA for safety compliance.
  • How flexible is the control switch wiring?
    The switch can be connected into either side of the 24V DC supply circuit.
  • Is this suitable for Zone 0 applications?
    Yes, it carries full certification for Zone 0, IIC, T4-T6 hazardous areas.
🏷️ Tags: Control Driver

Escalar (V/f)

Vetor

Alimentado por corrente alternada

  • Confirme o modelo exato, número da peça e especificações antes de fazer o pedido.
  • Garanta a compatibilidade com sua máquina ou sistemas de controle atuais.
  • Entre em contato pelo sale@etowonauto.com ou pelo +8617859788089 para assistência técnica.
  • Verifique as opções de entrega, prazos e requisitos de envio.
  • Siga as instruções do fabricante e as melhores práticas durante a instalação.

Itens em estoque geralmente são despachados no mesmo dia útil. Para produtos que não estão disponíveis no momento, os prazos de despacho podem variar conforme a disponibilidade. O envio internacional está disponível, e os custos de envio são calculados de acordo com o destino, peso e transportadora escolhida.

Devoluções são aceitas dentro de 30 dias após o recebimento, desde que os itens estejam sem uso e em condição original. Os custos de envio para devolução são de responsabilidade do cliente. Por favor, entre em contato conosco antes de devolver qualquer item para receber a autorização de devolução.

Para mais detalhes, por favor, consulte nossa Política de Envio e Devolução.

Ver informações completas

GARANTA DESEMPENHO CONFIÁVEL DAS MÁQUINAS

Transforme sua casa com as mais recentes soluções multi-eletrônicas, desde iluminação inteligente até dispositivos controlados por voz — tudo projetado para tornar a vida mais fácil, segura e conectada. Otimize suas operações com o Sistema de Monitoramento Bently Nevada 3500, que oferece monitoramento em tempo real de vibração e condição das máquinas para prevenir falhas e maximizar o tempo de atividade.