Transforme sua casa com as mais recentes soluções multi-eletrônicas, desde iluminação inteligente até dispositivos controlados por voz — tudo projetado para tornar a vida mais fácil, segura e conectada. Otimize suas operações com o Sistema de Monitoramento Bently Nevada 3500, que oferece monitoramento em tempo real de vibração e condição das máquinas para prevenir falhas e maximizar o tempo de atividade.
SKU:BMEH586040
BMEH586040 Schneider Modicon M580 Redundant Processor 64MB
Manufacturer: Schneider
Product No.: BMEH586040
Product Type: Processor Module
Product Origin: FR
Payment:T/T, Western Union
Weight: 849g
Shipping port: Xiamen
Warranty: 12 months
Compartilhar
- Entrega Rápida
- Suporte 24 horas por dia, 7 dias por semana
- Garantia de Qualidade
Descrição
Schneider Electric BMEH586040 Modicon M580 Redundant Processor
Product Overview
The Schneider Electric BMEH586040 is the flagship redundant processor module for the Modicon M580 automation platform, supporting X80 and Quantum remote I/O racks. It features 64 MB combined program and data memory plus 4096 kB dedicated HSBY data memory, managing 61 Ethernet devices with 31 remote I/O stations. Weight is 0.849 kg (1.872 lbs).
Specifications
| Parameter | Value |
|---|---|
| Brand | Schneider Electric |
| Model | BMEH586040 |
| Product Line | Modicon M580 |
| Product Type | Redundant Processor Module |
| Number of Racks | 1 |
| Application Specific I/O | Counter, SSI Encoder, Serial Link, HART, Time Stamping, Motion Control |
| Integrated Connections | 1 x Ethernet TCP/IP Service, 2 x Ethernet TCP/IP Device Network, USB Mini B, 1 x Ethernet HSBY Port |
| Remote I/O Stations | 31 (2 X80 and Quantum Drops) |
| Distributed Equipment | 64 |
| Communication Module Capacity | 6 Ethernet, 16 AS-Interface |
| Communication Service | RIO Scanner, DIO Scanner |
| Program and Data Memory | 64 MB Integrated RAM |
| HSBY Data Memory | 4096 kB Integrated RAM |
| System Memory | 10 kB Integrated RAM |
| Expandable Flash | 4 GB Data Storage |
| Application Structure | 1 Cyclic/Periodic Master, 1 Periodic Fast Task |
| Instructions per ms | 40 Kinst/ms (65% Boolean + 35% fixed), 50 Kinst/ms (100% Boolean) |
| Current Consumption | 365 mA @ 24 VDC |
| MTBF Reliability | 650,000 Hours |
| Protection Rating | IP20 |
| Operating Temperature | 0 to 60 °C |
| Storage Temperature | -40 to 85 °C |
| Relative Humidity | 5-95% at 55 °C (Non-Condensing) |
| Operating Altitude | 0-2000 m (2000-5000 m with Derating) |
| Vibration Resistance | 3 gn |
| Shock Resistance | 30 gn |
| Weight | 0.849 kg (1.872 lbs) |
| GTIN | 3606485440019 |
| Country of Origin | France (FR) |
Redundancy and Cybersecurity Features
- Dedicated Ethernet HSBY port with 4096 kB HSBY data memory
- A/B processor ID LEDs for redundant pair identification
- PRIM and STBY LEDs for primary/standby status monitoring
- REMOTE RUN LED for peer processor status
- Hsby Diag LED for hot standby link status
- Achilles Certified with DoS Prevention
- IPSec and Transport Layer Security
- SNMP Logging and Syslog Protocol Support
- Audit Trail, Embedded Firewall, Firmware Signature
- Password Protection, Port Hardening, HTTPS Communication
Certifications
- CE, UL, CSA, RCM, EAC
- Merchant Navy
- IEC 61131-2, IEC 61010-2-201
- UL 61010-2-201, CSA C22.2 No 61010-2-201
- IACS E10
- EN/IEC 61000-6-5 Interface Type 1 and 2
- EN/IEC 61850-3 Location G
- Hazardous Location Class I Division 2
Key Features
- 64 MB combined program and data memory, the highest capacity redundant processor
- 4096 kB dedicated HSBY data memory for hot standby synchronization
- Supports 31 remote I/O stations with X80 and Quantum rack compatibility
- 61 Ethernet devices and 64 distributed equipment units
- Dedicated Ethernet HSBY port for hot standby link
- Hot standby redundancy with primary/standby role indicators
- RIO and DIO scanner communication services
- 6 Ethernet and 16 AS-Interface communication module capacity
- High performance: 40 Kinst/ms mixed instructions, 50 Kinst/ms Boolean
- Achilles-certified cybersecurity with embedded firewall and IPSec
- 650,000 hours MTBF reliability rating
- Class I Division 2 hazardous location approved
- Marine certified for merchant navy applications
Installation Notes
Install the redundant processor in a Modicon M580 rack with internal power supply. Configure processor A/B IDs using the dedicated A and B LEDs for redundant pair identification. Connect the Ethernet HSBY port between primary and standby processors to establish the hot standby link with 4096 kB data synchronization. Monitor PRIM, STBY, REMOTE RUN, and Hsby Diag LEDs for redundancy status. Configure RIO and DIO scanner services for remote I/O communication with X80 and Quantum racks. Enable cybersecurity features including firewall, IPSec, and HTTPS. For altitudes above 2000 meters, apply derating factors.
FAQs
Q1: What is the memory capacity of the BMEH586040?
A1: 64 MB combined program and data memory, plus 4096 kB dedicated HSBY data memory for hot standby synchronization.
Q2: How many remote I/O stations does this redundant processor support?
A2: 31 remote I/O stations with 2 X80 and Quantum drop capability.
Q3: What is the instruction execution performance?
A3: 40 Kinst/ms with 65% Boolean + 35% fixed arithmetic, or 50 Kinst/ms with 100% Boolean.
Especificações Adicionais
- Cinza
- Prata
- Alimentado por corrente contínua
- Compacto
Escalar (V/f)
Vetor
Alimentado por corrente alternada
Guia de Compra
- Confirme o modelo exato, número da peça e especificações antes de fazer o pedido.
- Garanta a compatibilidade com sua máquina ou sistemas de controle atuais.
- Entre em contato pelo sale@etowonauto.com ou pelo +8617859788089 para assistência técnica.
- Verifique as opções de entrega, prazos e requisitos de envio.
- Siga as instruções do fabricante e as melhores práticas durante a instalação.
Envio e Devolução
Itens em estoque geralmente são despachados no mesmo dia útil. Para produtos que não estão disponíveis no momento, os prazos de despacho podem variar conforme a disponibilidade. O envio internacional está disponível, e os custos de envio são calculados de acordo com o destino, peso e transportadora escolhida.
Devoluções são aceitas dentro de 30 dias após o recebimento, desde que os itens estejam sem uso e em condição original. Os custos de envio para devolução são de responsabilidade do cliente. Por favor, entre em contato conosco antes de devolver qualquer item para receber a autorização de devolução.
Para mais detalhes, por favor, consulte nossa Política de Envio e Devolução.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Envio Rápido
Peças originais de automação industrial disponíveis para envio rápido em todo o mundo.
-
Devoluções Fáceis
Suporte para devolução em 30 dias com garantia de 12 meses para proteção confiável pós-venda.
-
Suporte 24 horas por dia, 7 dias por semana
Suporte profissional responsivo para ajudar a manter operações estáveis e eficientes.
-
Autêntico e Original
100% autêntico, proveniente diretamente de fabricantes confiáveis de automação industrial.
Guia Técnico e de Compra
-
What Makes GE Mark VIe the Top Turbine Control DCS?
GE Mark VIe is a high-performance turbine control DCS built for gas and steam power plants. It combines fast scan cyc...
-
What Makes Emerson DeltaV M-Series Ideal for Oil & Gas DCS Control?
Emerson's DeltaV M-Series controller delivers reliable regulatory control for oil and gas assets through MQ and MX va...
-
What Makes Siemens PCS 7 AS410 Ideal for Chemical DCS?
Siemens PCS 7 with the AS410 automation station delivers high availability for continuous chemical manufacturing. Thi...
-
What Causes Most ABB AC800M Migration Failures?
ABB AC800M controllers have run for 12 to 18 years in many plants, and spare part lead times now reach 16 weeks. This...
-
How to Migrate Honeywell TDC3000 to Experion PKS?
This guide explains how process plants can migrate aging Honeywell TDC3000 DCS systems to Experion PKS C300 through p...
-
What Makes PLC and DCS Migration Projects Succeed?
Multi-vendor control system migration demands disciplined project management, early interface testing, and structured...