Transforme sua casa com as mais recentes soluções multi-eletrônicas, desde iluminação inteligente até dispositivos controlados por voz — tudo projetado para tornar a vida mais fácil, segura e conectada. Otimize suas operações com o Sistema de Monitoramento Bently Nevada 3500, que oferece monitoramento em tempo real de vibração e condição das máquinas para prevenir falhas e maximizar o tempo de atividade.
SKU:1756-IT6I
Allen-Bradley 1756-IT6I ControlLogix 6-Channel Isolated Thermocouple Module
Manufacturer: Allen-Bradley
Product No.: 1756-IT6I
Product Type: Analog Input Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 320g
Shipping port: Xiamen
Warranty: 12 months
Compartilhar
- Entrega Rápida
- Suporte 24 horas por dia, 7 dias por semana
- Garantia de Qualidade
Descrição
Product Overview
The Allen-Bradley 1756-IT6I is a premium, high-resolution 6-channel isolated thermocouple input module belonging to the elite ControlLogix automation family. Engineered for precise temperature tracking in harsh processing environments, this module features six individually isolated thermocouple channels alongside an independent Cold-Junction Compensation (CJC) input. Weighing approximately 0.32 kg (0.71 lbs), this compact chassis-mounted module delivers exceptional 16-bit analog-to-digital conversion directly within the ControlLogix backplane system, safeguarding your thermal loops against erratic ground potentials and high-frequency electromagnetic noise without adding substantial structural strain.
Core Technical Advantages
- Individually Isolated Channels: Features complete channel-to-channel and channel-to-backplane electrical isolation, effectively suppressing common-mode line interference and ground loops to maintain flawless measurement accuracy.
- Dual-Mode High-Resolution Sensing: Delivers a sharp 16-bit diagnostic architecture, providing ultra-fine typical resolution down to 0.7 microvolts per bit when operating within the high-resolution millivolt range.
- Versatile Data Representation: Supports multiple processing profiles including left-justified two's complement integer formatting and standard IEEE 32-bit floating-point arrays for seamless controller scaling.
Technical Specifications
| Parameter | Specification Details |
|---|---|
| Brand / Manufacturer | Allen-Bradley / Rockwell Automation (ControlLogix System) |
| Model Part Number | 1756-IT6I (Series A/B Compatible) |
| Gross Weight | 0.32 kg (0.71 lbs) |
| Analog Inputs Count | 6 isolated thermocouple inputs and 1 dedicated CJC sensor path |
| Standard Signal Range | minus 12 to plus 78 mV (typical resolution of 1.4 microvolts/bit) |
| High-Resolution Range | minus 12 to plus 30 mV (typical resolution of 0.7 microvolts/bit) |
| Backplane Bus Current | 250 mA at 5 VDC / 125 mA at 24 VDC |
| Maximum Power Dissipation | 4.3 Watts maximum under peak operational thermal load |
| Minimum Module Scan Time | 10 ms (integer mV), 25 ms (float mV), 50 ms (float temperature) |
| Removable Terminal Blocks | Compatible with 1756-TBNH and 1756-TBSH mechanical blocks |
Installation & Engineering Guide
- Chassis Slot Integration: Shut down the primary control rack power supply before installation. Slide the 0.32 kg hardware framework smoothly into any open slot of the ControlLogix chassis, ensuring the top and bottom retention guides are firmly locked onto the structural framing rails.
- CJC Terminal Assembly: Wire the external field sensor loops through a compatible 1756-TBNH or 1756-TBSH removable terminal block. Ensure that the dedicated Cold-Junction Compensation (CJC) thermistor is correctly seated and wired to optimize absolute thermal tracking.
- Scan Time Optimization: Select the matching data format profile in your Logix Designer programming environment. If executing fast-acting loop dynamics, select the integer millivolt mode to drop the native module processing latency down to a 10 ms cycle.
Technical FAQs
Q1: What structural advantage does channel-to-channel isolation provide on the 1756-IT6I?
A1: Channel-to-channel isolation guarantees that each individual thermocouple sensor operates on an independent electrical plane. If one field thermocouple accidentally shorts to a high-voltage metal casing, the resulting surge is confined to that channel, fully protecting the other five sensors and the core PLC processor backplane from cascading failures.
Q2: Why does this module require a separate CJC input path?
A2: A Cold-Junction Compensation input is necessary because terminating thermocouple wires into copper terminal blocks creates secondary thermoelectric junctions. The CJC sensor tracks ambient block temperatures in real time, allowing the internal software to mathematically cancel out terminal errors and maintain accurate sensor telemetry.
Q3: Does the lightweight profile of this module impact its structural stability under high-vibration conditions?
A3: No. At only 0.32 kg, its specialized lightweight engineering optimizes the module for dense multi-slot configurations while easily satisfying standard ControlLogix industrial specifications for shock, thermal endurance, and heavy industrial vibration mapping.
Especificações Adicionais
Escalar (V/f)
Vetor
Alimentado por corrente alternada
Guia de Compra
- Confirme o modelo exato, número da peça e especificações antes de fazer o pedido.
- Garanta a compatibilidade com sua máquina ou sistemas de controle atuais.
- Entre em contato pelo sale@etowonauto.com ou pelo +8617859788089 para assistência técnica.
- Verifique as opções de entrega, prazos e requisitos de envio.
- Siga as instruções do fabricante e as melhores práticas durante a instalação.
Envio e Devolução
Itens em estoque geralmente são despachados no mesmo dia útil. Para produtos que não estão disponíveis no momento, os prazos de despacho podem variar conforme a disponibilidade. O envio internacional está disponível, e os custos de envio são calculados de acordo com o destino, peso e transportadora escolhida.
Devoluções são aceitas dentro de 30 dias após o recebimento, desde que os itens estejam sem uso e em condição original. Os custos de envio para devolução são de responsabilidade do cliente. Por favor, entre em contato conosco antes de devolver qualquer item para receber a autorização de devolução.
Para mais detalhes, por favor, consulte nossa Política de Envio e Devolução.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Envio Rápido
Peças originais de automação industrial disponíveis para envio rápido em todo o mundo.
-
Devoluções Fáceis
Suporte para devolução em 30 dias com garantia de 12 meses para proteção confiável pós-venda.
-
Suporte 24 horas por dia, 7 dias por semana
Suporte profissional responsivo para ajudar a manter operações estáveis e eficientes.
-
Autêntico e Original
100% autêntico, proveniente diretamente de fabricantes confiáveis de automação industrial.
Guia Técnico e de Compra
-
Why Driver Version Matching Matters for FactoryTalk Setup?
This guide provides standardized workflows for integrating Emerson DeltaV, ABB AC800, and GE Fanuc 90 with FactoryTal...
-
Can You Trust Your ABB and Bently Nevada MRO Supplier?
This article presents five data-backed standards for selecting an industrial automation parts supplier for ABB, Allen...
-
Can VersaMax PLC Expansion Fix Auto I/O Bottlenecks?
This article examines GE Fanuc VersaMax PLC expansion for automotive assembly I/O constraints. A 12-station SUV plant...
-
Is Your Legacy DCS Costing You 35% More Downtime Each Year?
This technical article presents a data-driven strategy for migrating end-of-life Emerson DCS to ABB 800F systems with...
-
What Is the Real Hourly Cost of Automation Downtime?
Industrial automation downtime creates severe financial losses, with PLC and DCS hardware failures causing 62% of unp...
-
Does Bently Nevada & PLC Integration Cut Refinery Downtime?
This article details a field-validated Bently Nevada 3500 and Allen-Bradley ControlLogix integration for oil and gas ...