Przejdź do treści
Części do automatyki, dostawa na cały świat
Pomiń, aby przejść do informacji o produkcie
1 z 3

SKU:ATV71HC11N4D

Schneider Variable Speed Drive 215A | ATV71HC11N4D

Na stanie (22 sztuk), gotowe do wysyłki
  • Manufacturer: Schneider

  • Product No.: ATV71HC11N4D

  • Product Type: Variable Speed Drive

  • Product Origin: FR

  • Payment:T/T, Western Union

  • Weight: 90000g

  • Shipping port: Xiamen

  • Warranty: 12 months

30-dniowa polityka zwrotów · 12-miesięczna gwarancja
  • Szybka dostawa
  • Wsparcie całodobowe
  • Zapewnienie jakości

Opis

Schneider Electric ATV71HC11N4D Altivar 71 Variable Speed Drive

Schneider Electric ATV71HC11N4D | Altivar 71 variable speed drive for complex, high-power machines. Delivers 110 kW (150 HP) motor power with 215 A nominal output current at 380-480V three-phase supply. Integrated EMC filter and heat sink. Reinforced version without DC choke, designed for door mounting. Supports asynchronous and synchronous motors. Weight: 90 kg (198.4 lbs).

Technical Specifications

Manufacturer Schneider Electric
Part Number ATV71HC11N4D
Product Line Altivar 71
Product Type Variable Speed Drive
Motor Power 110 kW (150 HP), 3-phase 380-480V
Supply Voltage 380-480V (-15%/+10%), 3-phase
Supply Voltage Limits 323-528V
Supply Frequency 50-60 Hz ±5% (47.5-63 Hz)
Line Current (480V) 163 A
Line Current (380V) 202 A
Apparent Power 133 kVA @ 380V
Nominal Output Current 215 A @ 2.5 kHz
Maximum Transient Current 323 A for 60 s; 355 A for 2 s
Output Frequency 0.1-500 Hz
Nominal Switching Frequency 2.5 kHz (adjustable 2.5-8 kHz)
Prospective Line Isc 35 kA
EMC Filter Integrated
Heat Sink Yes
Variant Reinforced version, without DC choke
Mounting Type Door Mount
Control Methods Sensorless Vector, Vector, V/f, Synchronous
Braking to Standstill DC injection
Analog Inputs 2 (AI1 ±10V, AI2 0-20mA/0-10V)
Analog Output 1 (AO1 0-20mA/0-10V)
Discrete Inputs 7 (LI1-LI5 programmable 24VDC, LI6 configurable, PWR safety)
Discrete Outputs 2 relay (R1 NO/NC, R2 NO)
Communication Modbus (2-wire RS485), CANopen
Transmission Rates (Modbus) 4800, 9600, 19200, 38.4 kbps
Transmission Rates (CANopen) 20 kbps to 1 Mbps
Speed Accuracy (Closed-Loop) ±0.01% of nominal speed
Torque Accuracy (Closed-Loop) ±5%
Transient Overtorque 170% for 60 s; 220% for 2 s
Braking Torque (with resistor) ≤150%
Insulation Resistance >1 MOhm at 500V DC for 1 minute
Dielectric Strength 3535V DC (earth to power); 5092V DC (control to power)
Protection Class IP54 (lower), IP41 (upper), IP30 (front/sides), IP00
Noise Level 69.5 dB (86/188/EEC)
Operating Temperature -10°C to +50°C (without derating)
Storage Temperature -25°C to +70°C
Relative Humidity 5-95% (non-condensing)
Operating Altitude ≤1000 m without derating; 1000-3000 m with 1% derating per 100 m
Vibration Resistance 0.6 gn (10-200 Hz); 1.5 mm peak-to-peak (3-10 Hz)
Shock Resistance 7 gn, 11 ms (EN/IEC 60068-2-27)
Dimensions (H x W x D) 1022 x 360 x 377 mm (40.2 x 14.2 x 14.8 in)
Net Weight 90 kg (198.4 lbs)
Gross Weight 121.56 kg (268.00 lbs)
Standards EN/IEC 61800-3, EN/IEC 61800-5-1, UL Type 1
Certifications CE, UL, CSA, GOST, NOM 117, C-tick

Additional Technical Parameters

Maximum Motor Cable Length (Shielded) 100 m (328.08 ft)
Maximum Motor Cable Length (Unshielded) 200 m (656.2 ft)
Analog Input Sampling Time 2 ms ±0.5 ms
Discrete Input Sampling Time 2 ms ±0.5 ms
STO Response Time ≤100 ms
Relay Output Response Time 7 ms ±0.5 ms
Analog Input Linearity Error ±0.15% of maximum value
Analog Output Linearity Error ±0.2%
Relay Mechanical Life 100,000 cycles
Minimum Switching Current 3 mA at 24V DC

Installation Notes

Mount vertically (±10°) using door-mount configuration. Connect 380-480V three-phase supply per local electrical codes. Observe terminal tightening torques: 0.6 N·m for control terminals, 24 N·m for motor terminals, 12 N·m for PA/PB, 41 N·m for PC/PO/PA/+. Maximum motor cable length is 100 m shielded or 200 m unshielded. Maintain operating temperature within -10°C to +50°C without derating. For altitudes above 1000 m, apply 1% current derating per 100 m. The D suffix indicates no DC choke and no graphic terminal. Ensure proper grounding and use the integrated EMC filter for electromagnetic compliance.

FAQs

Q1: What is the motor power rating of this drive?
A1: 110 kW (150 HP) at 380-480V three-phase supply.

Q2: What communication protocols are built in?
A2: Modbus (2-wire RS485) and CANopen.

Q3: What does the D suffix indicate?
A3: The drive is a reinforced version without a DC choke and without a remote graphic terminal.

🏷️ Tags: Variable Speed Drive

Skalar (V/f)

Wektor

Zasilany prądem zmiennym

  • Potwierdź dokładny model, numer części oraz specyfikacje przed złożeniem zamówienia.
  • Upewnij się, że jest kompatybilny z Twoimi obecnymi maszynami lub systemami sterowania.
  • Skontaktuj się pod adresem sale@etowonauto.com lub pod numerem +8617859788089, aby uzyskać pomoc techniczną.
  • Sprawdź opcje dostawy, czas realizacji oraz wymagania dotyczące wysyłki.
  • Postępuj zgodnie z instrukcjami producenta i najlepszymi praktykami podczas instalacji.

Produkty dostępne w magazynie są zazwyczaj wysyłane tego samego dnia roboczego. W przypadku produktów chwilowo niedostępnych czas wysyłki może się różnić w zależności od dostępności. Oferujemy wysyłkę międzynarodową, a koszty przesyłki są obliczane na podstawie miejsca docelowego, wagi oraz wybranego przewoźnika.

Zwroty są akceptowane w ciągu 30 dni od otrzymania, pod warunkiem, że produkty są nieużywane i w oryginalnym stanie. Koszty zwrotu ponosi klient. Prosimy o kontakt przed zwrotem jakiegokolwiek produktu, aby uzyskać autoryzację zwrotu.

Więcej informacji znajdziesz w naszej Polityce wysyłki i zwrotów.

Pokaż kompletne dane

ZAPEWNIJ NIEZAWODNĄ PRACĘ MASZYN

Przekształć swój dom dzięki najnowszym rozwiązaniom multi-elektronicznym, od inteligentnego oświetlenia po urządzenia sterowane głosem — wszystko zaprojektowane, aby życie było łatwiejsze, bezpieczniejsze i bardziej połączone.

Optymalizuj swoje operacje dzięki systemowi monitorowania Bently Nevada 3500, oferującemu monitorowanie drgań i stanu maszyn w czasie rzeczywistym, aby zapobiegać awariom i maksymalizować czas pracy.