GE IS215ACLEH1B ACLE Module Mark VI EX2100 Control

Na stanie (20 sztuk), gotowe do wysyłki
  • Manufacturer: General Electric

  • Product No.: IS215ACLEH1B

  • Product Type: Circuit Board

  • Product Origin: USA

  • Payment:T/T, Western Union

  • Weight: 570g

  • Shipping port: Xiamen

  • Warranty: 12 months

30-dniowa polityka zwrotów · 12-miesięczna gwarancja
  • Szybka dostawa
  • Wsparcie całodobowe
  • Zapewnienie jakości

Opis

Product Overview

The GE Energy IS215ACLEH1B (Functional Acronym: ACLE) is a high-performance Application Control Layer Module designed for General Electric's Mark VI Speedtronic Gas Turbine Control Systems and EX2100 / EX2100e Excitation Control Systems. Engineered for critical industrial control applications, this microprocessor-based controller manages real-time turbine control logic, subsystem coordination, complex communication protocols, and system diagnostics.

Featuring an "IS215" domestic special modular assembly prefix, the IS215ACLEH1B is built with a dual-slot metal faceplate tailored for standard GE VME rack structures and control cabinets. Operating with a 125 V DC input voltage and 24 V DC output, it incorporates a high-speed PCI controller, 128 KB L2 cache, 10BaseT RJ45 Ethernet communication, non-volatile flash memory, and an array of front-panel LED status indicators. Weighing approximately 0.57 kg (1.25 lbs), this Grade B functional revision module delivers robust online application loading and real-time control block processing across demanding energy environments.

Core Technical Advantages

  • Advanced Microprocessor & PCI Controller Architecture: Equipped with an onboard CPU, PCI controller, and 128 KB Level 2 cache to optimize data transfers and high-speed input/output processing.
  • Comprehensive Network & Bus Connectivity: Features 10BaseT RJ45 Ethernet (IRQ 5 initialization via BIOS) for seamless communication over ISBus networks, SCADA systems, and central control hubs.
  • Flexible Software & Logic Capabilities: Supports online application configuration loading, non-volatile flash memory storage, control block execution, and real-time forcing of I/O points and internal booleans.
  • VME Rack & Dual-Slot Integration: Engineered with a specialized installation faceplate that occupies two half-slots in standard EX2100 exciter board racks or Innovation Series drives.

Technical Specifications

Parameter Specification Details
Brand / Manufacturer General Electric / GE Energy
Full Catalog Part Number IS215ACLEH1B
Product Series Mark VI Series / EX2100 & EX2100e Excitation System
Functional Acronym ACLE (Application Control Layer)
Product Description Application Control Layer Module
Input / Output Voltage Input: 125 V DC | Output: 24 V DC
Operating Temperature Range -30°C to +65°C (-22°F to +149°F)
Cache Architecture Level 2, 128 KB (Controlled via PCI Controller)
Ethernet Port Type 10BaseT RJ45 Connector (Front Panel)
Mounting & Rack Form Factor VME Rack Structure / Occupies 2 Half-Slots (Faceplate)
Board Dimensions 23.495 cm (H) x 10.795 cm (W)
Functional Revision 1 B (Singular B-grade functional revision)
Country of Manufacture United States (USA)
Estimated Shipping Weight Approx. 0.57 kg (1.25 lbs)

Installation & Handling Guidelines

  • ESD Protection & Static Safety: Always handle the ACLE board using a grounded wrist strap and static-safe equipment to avoid damaging onboard microprocessors and flash memory ICs.
  • VME Rack Slot Insertion: Align the metal faceplate guide rails carefully into the two half-slots of the EX2100 exciter rack or Innovation drive cabinet before securing the faceplate retaining screws.
  • Ethernet & Cable Connection: Connect standard RJ45 Ethernet cabling directly to the front-panel 10BaseT port, ensuring correct pin alignment and cable strain relief within the cabinet.

Technical FAQs

Q1: What is the main function of the GE IS215ACLEH1B module in turbine control systems?
A1: It executes control logic, manages communication networks, enforces safety protocols, and coordinates subsystems.

Q2: How does the IS215ACLEH1B module mount within the control cabinet?
A2: It uses a metal installation faceplate designed to occupy two half-slots in standard EX2100 VME racks.

Q3: What Ethernet communication interface is featured on the front panel of the IS215ACLEH1B board?
A3: It features a 10BaseT RJ45 jack initialized by BIOS, managed via an onboard PCI controller.

  • Zielony

Skalar (V/f)

Wektor

Zasilany prądem zmiennym

  • Potwierdź dokładny model, numer części oraz specyfikacje przed złożeniem zamówienia.
  • Upewnij się, że jest kompatybilny z Twoimi obecnymi maszynami lub systemami sterowania.
  • Skontaktuj się pod adresem sale@etowonauto.com lub pod numerem +8617859788089, aby uzyskać pomoc techniczną.
  • Sprawdź opcje dostawy, czas realizacji oraz wymagania dotyczące wysyłki.
  • Postępuj zgodnie z instrukcjami producenta i najlepszymi praktykami podczas instalacji.

Produkty dostępne w magazynie są zazwyczaj wysyłane tego samego dnia roboczego. W przypadku produktów chwilowo niedostępnych czas wysyłki może się różnić w zależności od dostępności. Oferujemy wysyłkę międzynarodową, a koszty przesyłki są obliczane na podstawie miejsca docelowego, wagi oraz wybranego przewoźnika.

Zwroty są akceptowane w ciągu 30 dni od otrzymania, pod warunkiem, że produkty są nieużywane i w oryginalnym stanie. Koszty zwrotu ponosi klient. Prosimy o kontakt przed zwrotem jakiegokolwiek produktu, aby uzyskać autoryzację zwrotu.

Więcej informacji znajdziesz w naszej Polityce wysyłki i zwrotów.

Pokaż kompletne dane

ZAPEWNIJ NIEZAWODNĄ PRACĘ MASZYN

Przekształć swój dom dzięki najnowszym rozwiązaniom multi-elektronicznym, od inteligentnego oświetlenia po urządzenia sterowane głosem — wszystko zaprojektowane, aby życie było łatwiejsze, bezpieczniejsze i bardziej połączone.

Optymalizuj swoje operacje dzięki systemowi monitorowania Bently Nevada 3500, oferującemu monitorowanie drgań i stanu maszyn w czasie rzeczywistym, aby zapobiegać awariom i maksymalizować czas pracy.