8440-1935 Woodward easYgen-3500 Sheet Metal Chassis CPU

Na stanie (11 sztuk), gotowe do wysyłki
  • Manufacturer: Woodward

  • Product No.: 8440-1935

  • Product Type: Operator Interface

  • Product Origin: USA

  • Payment:T/T, Western Union

  • Weight: 1850g

  • Shipping port: Xiamen

  • Warranty: 12 months

30-dniowa polityka zwrotów · 12-miesięczna gwarancja
  • Szybka dostawa
  • Wsparcie całodobowe
  • Zapewnienie jakości

Opis

Product Overview

The 8440-1935 (alternatively designated as the easYgen-3500-1-P1) is an advanced genset controller from Woodward's easYgen-3000 series. Housed in a durable sheet metal chassis designed for cabinet installation, this unit features integrated generator group breaker control. Weighing approximately 4.08 lbs (1,850 g) with front panel dimensions of 282W x 216H x 96D mm, it delivers high-precision power management with 16-bit resolution and an Accuracy Class of 0.5.

Core Technical Advantages

  • High-Precision Measurement: Engineered to Accuracy Class 0.5 with 16-bit resolution and a wide setting range from 1 to 32,000 A.
  • Integrated Breaker Control: Equipped with built-in generator group breaker control for seamless synchronization and switching.
  • Isolated Discrete Inputs: Features robust isolated discrete input channels to protect internal circuitry from field electrical noise.
  • Rugged Sheet Metal Build: Sturdy 1,850 g chassis built to withstand harsh industrial generator control environments.

Technical Specifications

Parameter Specification Details
Manufacturer & Series Woodward Inc. / easYgen-3000 Series
Part Number / Model 8440-1935 (easYgen-3500-1-P1)
Accuracy Class & Resolution Accuracy Class 0.5; 16-Bit Resolution
Current Setting Range 1 to 32,000 A
Discrete Inputs Isolated Discrete Inputs
Chassis & Dimensions Sheet Metal Chassis; 282W x 216H x 96D mm
Net Weight Approx. 1,850 g (4.08 lbs)
Power Factor Circuits Supports Capacitive, Resistive (Unity 1.00), and Inductive Circuits

Industrial Solutions

  • Standby & Prime Power Generators: Manages automatic start/stop, synchronization, and breaker control for diesel and gas generator sets.
  • Multi-Gen Paralleling Systems: Coordinates load sharing and power factor regulation across complex multi-generator installations.
  • Industrial Power Management: Provides reliable monitoring and protection in industrial switchgear and utility backup panels.

Wiring & Installation

Cabinet Mounting & Chassis Grounding

Install the controller inside a protective industrial cabinet using the 282W x 216H x 96D mm cutout profile. Do not connect wires directly to the protective earth terminal on the controller body; route any necessary ground connections exclusively through the designated bottom connector.

Current Transformer Safety Precaution

Always ensure that current transformers (CTs) are properly short-circuited before disconnecting wiring from the controller. Failing to short-circuit CTs during disconnection can result in hazardous high voltages, severe personal injury, or death.

Power Factor Configuration

Configure power factor parameters based on your system load type—capacitive, purely resistive (targeting unity 1.00 where voltage and current waveforms are in step), or inductive.

Engineering Advantages

  • Advanced Power Factor Management: Accurately calculates real-to-apparent power ratios across resistive, inductive, and capacitive circuit profiles.
  • Robust Isolation: Isolated discrete inputs safeguard internal processing components from heavy electrical transients.
  • Flexible Switchgear Integration: Built-in breaker control logic streamlines synchronization architecture in generator control panels.

Technical FAQs

Q1: What is the model designation and accuracy class of the 8440-1935?
A1: It is also known as the easYgen-3500-1-P1 and features an Accuracy Class of 0.5 with 16-bit resolution.

Q2: What safety precaution is critical when disconnecting current transformers?
A2: You must short-circuit the current transformer before disconnection to prevent severe injury or death from high voltage.

Q3: What are the physical dimensions and weight of this controller?
A3: Dimensions are 282W x 216H x 96D mm, with a net weight of approximately 1,850 g (4.08 lbs).

Skalar (V/f)

Wektor

Zasilany prądem zmiennym

  • Potwierdź dokładny model, numer części oraz specyfikacje przed złożeniem zamówienia.
  • Upewnij się, że jest kompatybilny z Twoimi obecnymi maszynami lub systemami sterowania.
  • Skontaktuj się pod adresem sale@etowonauto.com lub pod numerem +8617859788089, aby uzyskać pomoc techniczną.
  • Sprawdź opcje dostawy, czas realizacji oraz wymagania dotyczące wysyłki.
  • Postępuj zgodnie z instrukcjami producenta i najlepszymi praktykami podczas instalacji.

Produkty dostępne w magazynie są zazwyczaj wysyłane tego samego dnia roboczego. W przypadku produktów chwilowo niedostępnych czas wysyłki może się różnić w zależności od dostępności. Oferujemy wysyłkę międzynarodową, a koszty przesyłki są obliczane na podstawie miejsca docelowego, wagi oraz wybranego przewoźnika.

Zwroty są akceptowane w ciągu 30 dni od otrzymania, pod warunkiem, że produkty są nieużywane i w oryginalnym stanie. Koszty zwrotu ponosi klient. Prosimy o kontakt przed zwrotem jakiegokolwiek produktu, aby uzyskać autoryzację zwrotu.

Więcej informacji znajdziesz w naszej Polityce wysyłki i zwrotów.

Pokaż kompletne dane

ZAPEWNIJ NIEZAWODNĄ PRACĘ MASZYN

Przekształć swój dom dzięki najnowszym rozwiązaniom multi-elektronicznym, od inteligentnego oświetlenia po urządzenia sterowane głosem — wszystko zaprojektowane, aby życie było łatwiejsze, bezpieczniejsze i bardziej połączone.

Optymalizuj swoje operacje dzięki systemowi monitorowania Bently Nevada 3500, oferującemu monitorowanie drgań i stanu maszyn w czasie rzeczywistym, aby zapobiegać awariom i maksymalizować czas pracy.