Ubah rumah anda dengan penyelesaian multi-elektronik terkini, dari pencahayaan pintar hingga peranti kawalan suara — semua direka untuk memudahkan hidup, menjadikan ia lebih selamat, dan lebih berhubung. Optimumkan operasi anda dengan Sistem Pemantauan Bently Nevada 3500, yang menawarkan pemantauan getaran dan keadaan mesin secara masa nyata untuk mencegah kerosakan dan memaksimumkan masa operasi.
SKU:6ES7313-5BE00-0AB0
Siemens CPU 313C 6ES7313-5BE00-0AB0 S7-300 Compact Module
Manufacturer: Siemens
Product No.: 6ES7313-5BE00-0AB0
Product Type: CPU Module
Product Origin: DE
Payment:T/T, Western Union
Weight: 660g
Shipping port: Xiamen
Warranty: 12 months
Kongsi
- Penghantaran Pantas
- Sokongan 24/7
- Jaminan Kualiti
Penerangan
SIEMENS 6ES7313-5BE00-0AB0 SIMATIC S7-300 CPU 313C Compact CPU
The SIEMENS 6ES7313-5BE00-0AB0, also cataloged as the 6ES7313-5BE00-0AB0 CPU 313C, operates as a compact central processing unit with integrated digital and analog I/O, fast counters, and MPI communication executing user logic within SIMATIC S7-300 platforms.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | 6ES7313-5BE00-0AB0 |
| Brand | Siemens |
| Product Type | CPU 313C Compact CPU |
| Series | SIMATIC S7-300 |
| Rated Supply Voltage | 24 VDC |
| Permissible Range | 20.4 V to 28.8 VDC |
| Current Consumption | 700 mA rated |
| Inrush Current | 11 A typ. |
| Power Loss | 14 W typ. |
| Work Memory | 32 kbyte integrated, not expandable |
| Load Memory | MMC expandable to 4 Mbyte |
| Bit Operation Time | 0.1 us typ., 0.2 us max |
| Word Operation Time | 0.5 us typ. |
| Fixed Point Arithmetic | 1 us typ. |
| Floating Point Arithmetic | 15 us typ. |
| Digital Inputs | 24 |
| Digital Outputs | 16 |
| Analog Inputs | 4 plus 1 Pt100 |
| Analog Outputs | 2 |
| Fast Counters | 3 at 30 kHz |
| Pulse Outputs | 3 at 2.5 kHz limit frequency |
| MPI Interface | 1 x MPI, 8 connections, 187.5 kbit/s max |
| Dimensions (W x H x D) | 120 mm x 125 mm x 130 mm |
| Weight | 660 g (approx.) |
Integrated I/O, Analog Channels, and Counter Functions
Unit weight is approximately 660 g with dimensions of 120 mm width, 125 mm height, and 130 mm depth. The CPU 313C integrates 24 digital inputs, 16 digital outputs, 4 analog inputs, 2 analog outputs, and 1 Pt100 resistance thermometer input. Three fast counters operate at 30 kHz with frequency measurement and PID controller functions. Three pulse outputs operate at a limit frequency of 2.5 kHz. Analog inputs support 0 to 10 V, 0 to 20 mA, +/-20 mA, 4 to 20 mA, Pt100, and 0 to 600 ohm ranges with 12-bit resolution and parameterizable integration times of 2.5, 16.6, or 20 ms. Analog outputs support 0 to 10 V, +/-10 V, 0 to 20 mA, +/-20 mA, and 4 to 20 mA with 12-bit resolution and 1 ms conversion time per channel. Basic error limit at 25 deg C is +/-0.7% for voltage and current, +/-3% for resistance and resistance thermometer. The hardware real-time clock is retentive and synchronizable. Up to 3 expansion units and 31 modules per rack are supported. Programming languages include LAD, FBD, STL, SCL, GRAPH, and HiGraph. Configuration requires STEP 7 V5.1 SP2 or higher.
Frequently Asked Questions
Q: What is the weight and physical size of the 6ES7313-5BE00-0AB0?
A: Approximately 660 g, with dimensions of 120 mm width, 125 mm height, and 130 mm depth.
Q: How many fast counters and pulse outputs does the CPU 313C support?
A: Three fast counters at 30 kHz with frequency measurement, and three pulse outputs at a 2.5 kHz limit frequency.
Q: What analog signal ranges does the CPU 313C accept?
A: Inputs support 0 to 10 V, 0 to 20 mA, +/-20 mA, 4 to 20 mA, Pt100, and 0 to 600 ohms. Outputs support 0 to 10 V, +/-10 V, 0 to 20 mA, +/-20 mA, and 4 to 20 mA.
Field Installation Guidelines
Install the CPU in slot 2 of the S7-300 rail and secure the mounting screws. Verify 24 VDC supply polarity before energizing the backplane. Insert a micro memory card before downloading the program. Confirm STEP 7 V5.1 SP2 or higher is used for configuration. Route shielded analog and counter cables to a maximum of 100 m for technological functions; unshielded cables are permitted only for standard inputs and outputs up to 600 m. Verify total output current per group does not exceed 8 A at up to 40 deg C or 4 A at up to 60 deg C. Verify potential separation groups of 16 and 8 for digital inputs and 8 for digital outputs.
Spesifikasi Tambahan
- Dikuasakan oleh DC
- Modular
Skalar (V/f)
Vektor
Dikuasakan oleh AC
Panduan Membeli
- Sahkan model tepat, nombor bahagian, dan spesifikasi sebelum membuat pesanan.
- Pastikan keserasian dengan mesin atau sistem kawalan anda sekarang.
- Hubungi melalui sale@etowonauto.com atau +8617859788089 untuk bantuan teknikal.
- Semak pilihan penghantaran, masa penghantaran, dan keperluan penghantaran.
- Ikuti arahan pengeluar dan amalan terbaik semasa pemasangan.
Penghantaran dan Pemulangan
Barangan yang ada dalam stok biasanya dihantar pada hari perniagaan yang sama. Untuk produk yang tidak tersedia dalam stok, masa penghantaran mungkin berbeza bergantung pada ketersediaan. Penghantaran antarabangsa disediakan, dan kos penghantaran dikira mengikut destinasi, berat, dan pilihan pengangkut.
Pengembalian diterima dalam tempoh 30 hari selepas penerimaan, dengan syarat barangan tidak digunakan dan dalam keadaan asal. Kos penghantaran untuk pengembalian adalah tanggungjawab pelanggan. Sila hubungi kami sebelum memulangkan sebarang barangan untuk mendapatkan kebenaran pengembalian.
Untuk maklumat lanjut, sila semak Polisi Penghantaran & Pengembalian.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Penghantaran Pantas
Alat ganti automasi industri asli tersedia untuk penghantaran segera ke seluruh dunia.
-
Pemulangan Mudah
Sokongan pemulangan selama 30 hari dengan jaminan 12 bulan untuk perlindungan selepas jualan yang boleh dipercayai.
-
Sokongan 24/7
Sokongan profesional responsif untuk membantu mengekalkan operasi yang stabil dan cekap.
-
Asli & Tulen
100% asli, diperoleh terus dari pengeluar automasi industri yang dipercayai.
Panduan Teknikal & Pembelian
-
Troubleshoot Allen-Bradley PLC and ABB DCS Commissioning Faults?
Joint commissioning of Allen-Bradley PLC and ABB DCS systems demands rigorous signal mapping, layered diagnostics, an...
-
What Causes Packet Loss in DeltaV and ABB Fieldbus Networks?
This article explains how to optimize communication between Emerson DeltaV DCS and ABB fieldbus control modules ...
-
How Does Allen-Bradley Redundant PLC Improve DCS Safety?
This article explains how Allen-Bradley redundant PLC deployment supports petrochemical DCS safety control. It covers...
-
Can Mixed-Vendor PLCs Unite Without Full Replacement?
ABB industrial Ethernet modules translate protocols across Allen-Bradley, Siemens, and ABB PLC platforms in brownfiel...
-