Langkau ke kandungan
Bahagian automasi, bekalan seluruh dunia
Langkau ke maklumat produk
1 daripada 3

SKU:MTL5025

MTL5025 Hazardous Area Switch Controller - MTL Instruments

Stok ada (25 unit), sedia untuk dihantar
  • Manufacturer: MTL

  • Product No.: MTL5025

  • Product Type: Control Driver

  • Product Origin: USA

  • Payment:T/T, Western Union

  • Weight: 110g

  • Shipping port: Xiamen

  • Warranty: 12 months

Polisi Pemulangan 30 Hari · Jaminan 12 Bulan
  • Fast Delivery
  • 24/7 Support
  • Quality Assurance

Penerangan

MTL5025 Hazardous Area On/Off Driver

The MTL5025 from MTL Instruments provides reliable control of hazardous area devices from safe area switches or voltage changes. This single-channel interface drives intrinsically safe low-power loads and non-energy-storing apparatus like LEDs. 

Key Technical Specifications

  • Brand: MTL Instruments
  • Model: MTL5025
  • Product Type: Hazardous Area On/Off Driver
  • Channels: One channel
  • Output Current: 45mA maximum
  • Input Voltage: 20 to 35V DC
  • Status Indicator: Yellow LED for operational status

Hazardous Area Certification

  • Load Location: Zone 0, IIC, T4-T6 hazardous area
  • Division Rating: Division 1, Group A hazardous location
  • The MTL5025 maintains intrinsic safety for connected loads
  • It enables safe control of devices in explosive atmospheres

Output Performance

  • Minimum Output Voltage: 8.6V at 45mA
  • Maximum Output Voltage: 24V from 269Ω
  • Current Limit: 45mA maximum for safety
  • Output Terminals: Terminal 1 (Output –ve), Terminal 2 (Output +ve)
  • Suitable for intrinsically safe low-power loads and LED indicators

Power Requirements

  • Input Voltage: 20 to 35V DC operating range
  • Current Consumption: 90mA at 24V with 45mA output
  • Maximum Consumption: 110mA at 20-35V DC
  • Power Dissipation: 1.6W at 24V
  • Maximum Dissipation: 2.0W at 35V
  • Supply Terminals: Terminal 11 (Supply –ve), Terminal 12 (Supply +ve)

Safety Parameters

  • Safety Voltage: 25V maximum
  • Internal Resistance: 269Ω
  • Safety Current: 93mA maximum
  • Isolation Voltage: Um = 250V rms or DC
  • Comprehensive protection for hazardous area operation

Frequently Asked Questions

  • What type of loads can the MTL5025 drive?
    It drives intrinsically safe low-power loads and non-energy-storing apparatus like LEDs.
  • What is the maximum output current?
    The output is current limited to 45mA for safety compliance.
  • What is the minimum output voltage?
    It provides a minimum of 8.6V at 45mA for connected devices.
  • What hazardous areas is this certified for?
    It carries certification for Zone 0, IIC, T4-T6 and Division 1, Group A areas.
🏷️ Tags: Control Driver

Skalar (V/f)

Vektor

Dikuasakan oleh AC

  • Sahkan model tepat, nombor bahagian, dan spesifikasi sebelum membuat pesanan.
  • Pastikan keserasian dengan mesin atau sistem kawalan anda sekarang.
  • Hubungi melalui sale@etowonauto.com atau +8617859788089 untuk bantuan teknikal.
  • Semak pilihan penghantaran, masa penghantaran, dan keperluan penghantaran.
  • Ikuti arahan pengeluar dan amalan terbaik semasa pemasangan.

Barangan yang ada dalam stok biasanya dihantar pada hari perniagaan yang sama. Untuk produk yang tidak tersedia dalam stok, masa penghantaran mungkin berbeza bergantung pada ketersediaan. Penghantaran antarabangsa disediakan, dan kos penghantaran dikira mengikut destinasi, berat, dan pilihan pengangkut.

Pengembalian diterima dalam tempoh 30 hari selepas penerimaan, dengan syarat barangan tidak digunakan dan dalam keadaan asal. Kos penghantaran untuk pengembalian adalah tanggungjawab pelanggan. Sila hubungi kami sebelum memulangkan sebarang barangan untuk mendapatkan kebenaran pengembalian.

Untuk maklumat lanjut, sila semak Polisi Penghantaran & Pengembalian.

Lihat Butiran Produk

PASTIKAN PRESTASI MESIN YANG BOLEH DIPERCAYAI

Ubah rumah anda dengan penyelesaian multi-elektronik terkini, dari pencahayaan pintar hingga peranti kawalan suara — semua direka untuk memudahkan hidup, menjadikan ia lebih selamat, dan lebih berhubung. Optimumkan operasi anda dengan Sistem Pemantauan Bently Nevada 3500, yang menawarkan pemantauan getaran dan keadaan mesin secara masa nyata untuk mencegah kerosakan dan memaksimumkan masa operasi.