Ubah rumah anda dengan penyelesaian multi-elektronik terkini, dari pencahayaan pintar hingga peranti kawalan suara — semua direka untuk memudahkan hidup, menjadikan ia lebih selamat, dan lebih berhubung. Optimumkan operasi anda dengan Sistem Pemantauan Bently Nevada 3500, yang menawarkan pemantauan getaran dan keadaan mesin secara masa nyata untuk mencegah kerosakan dan memaksimumkan masa operasi.
SKU:IC693DNM200
IC693DNM200 DeviceNet Master Module | 5V DC 450mA Single-Slot GE
Manufacturer: General Electric
Product No.: IC693DNM200
Product Type: DeviceNet Master Module
Product Origin: USA
Payment:T/T, Western Union
Weight: 500g
Shipping port: Xiamen
Warranty: 12 months
Kongsi
- Penghantaran Pantas
- Sokongan 24/7
- Jaminan Kualiti
Penerangan
GE Fanuc Series 90-30 IC693DNM200 Overview
The GE Fanuc IC693DNM200 is a high-performance, single-slot DeviceNet Master Module engineered for the legacy Series 90-30 and modern PACSystems RX3i Programmable Logic Controller (PLC) architectures. Manufactured formerly by GE Fanuc and now supported under Emerson Automation, this communication interface serves as a centralized industrial network hub, allowing host controllers to seamlessly exchange I/O mapping data with distributed field devices. The hardware design features a compact, single-slot form factor with a lightweight profile of 0.5 kg (approximately 1.1 lbs), optimizing physical space utilization across internal rack layouts. Functioning via an internal logic current draw of 450 milliamps at 5.0 Volts DC, this module delivers robust network bridging capabilities, acting simultaneously in dual-mode configuration as both a Master node and a Slave device to facilitate localized processing and factory-wide automation synchronization.
Core Network Features & Data Architecture
DeviceNet Capacity and Protocol Support
The IC693DNM200 is built to establish stable network structures, accommodating up to 63 independent DeviceNet slave units. It supports standard protocol transmission speeds, operating at 125K, 250K, and 500K Baud rates depending on overall bus distance and infrastructure needs. For advanced industrial communication, the module integrates extensive messaging toolsets, including explicit messaging routines, Unconnected Message Manager (UCMM) architectures, and 1 dedicated proxy connection per assigned slave terminal.
Data Transmission Limits and I/O Connections
Designed for substantial diagnostic data logging and dense field array management, the master module supports a large aggregate bandwidth. It is capable of transferring up to 255 Bytes of input data and 255 Bytes of output data per individual slave unit, with an absolute maximum data transfer throughput to the host Master reaching 3,972 Input Bytes and 3,972 Output Bytes. A total of 126 concurrent I/O connections can be sustained across the network bus, allowing up to 2 distinct I/O station links to be established for each connected field device.
Configurable Transfer Connections & Fault Logic
To optimize communication latency and network traffic based on physical machinery constraints, data synchronization can be structured into Poll, Strobe, Cyclic, or Change-of-State (COS) I/O configurations. Furthermore, the firmware incorporates a user-configurable fault behavior routine, allowing automated system engineers to establish precise, safe fallback reactions and machine hold states in the event of sudden bus communication timeouts or network line breaks.
Technical Specifications Table
| Technical Parameter | Specification Details |
|---|---|
| Brand / Manufacturer | GE Fanuc / Emerson Automation |
| Product Series | Series 90-30 PLC & PACSystems RX3i |
| Part Number | IC693DNM200 |
| Module Type | DeviceNet Network Master Module (Single-Slot) |
| Physical Ports | 1 DeviceNet Terminal; 1 RS-232 9-Pin D-Shell Female Service Port |
| Supported Network Speeds | 125K, 250K, and 500K Baud Rates |
| Maximum Slave Node Capacity | Up to 63 DeviceNet Slaves / 126 Total I/O Connections |
| Max Data Rate Per Slave Node | 255 Input Bytes / 255 Output Bytes |
| Max Total Aggregate Data | 3972 Input Bytes / 3972 Output Bytes to Master |
| Rated Channel I/O Voltage | 12 to 24 Volts DC (VDC), Positive Logic configuration |
| Continuous Channel Output Current | 0.5 Amps (A) per point; 4.0 Amps maximum per channel group |
| Inrush Current Rating | 5.4 Amps (A) sustained for a maximum duration of 10 ms |
| Backplane Current Draw | 450 milliamps (mA) typical consumption at 5V DC |
| I/O Channel Response Time | ON / OFF signal response times not exceeding 0.5 ms |
| Total Assembly Weight | 0.5 Kilograms (kg) / Approx. 1.1 Pounds net weight |
Installation, Hardware Routing, & Electrical Guidelines
Mechanical Layout and Rack Placement Safety
The IC693DNM200 single-slot communication card is designed to sit exclusively within the main system rack of a Series 90-30 or PACSystems RX3i assembly. To ensure proper addressing and electrical line integrity, the module can be placed into any standard slot on the main baseplate, with the strict exception of slots 0 and 1, which are reserved for system power supplies and CPU controllers. Please note that this communication module does not support integration into remote or expansion racks. Prior to sliding the card into the backplane, confirm the power supply is off to protect the communication chipsets from damage.
Channel Groupings and Output Current Limits
The module features 32 onboard output points grouped into sets of four, with each group covering 8 distinct output points. When wiring the external 12-24V DC positive logic field array, engineers must follow specific electrical thresholds to avoid overheating the traces. While each separate point can handle a continuous current load of up to 0.5 Amps, the absolute collective limit per group must not surpass 4.0 Amps. Additionally, ensure the continuous current passing through any single group common pin does not exceed 3.0 Amps.
Firmware Upgrades and Diagnostic Service Routing
The front faceplate of the IC693DNM200 houses a single DeviceNet plug-in terminal alongside an isolated 9-pin D-shell female RS-232 service port. This serial line serves as a local interface for executing diagnostic checks and applying system patches. Because the device is built with upgradeable flash memory, field technicians can download the latest firmware iterations and security patches directly via the RS-232 port, avoiding the need for physical chip swaps during routine system maintenance.
Frequently Asked Questions (FAQs)
Q1: Can I install the IC693DNM200 module into an expansion rack to save space on my main PLC baseplate?
A1: No. The IC693DNM200 must be installed directly on the main rack of a Series 90-30 or PACSystems RX3i setup. The internal architecture of the module requires direct, high-speed backplane mapping that is not supported through the bus cables of expansion or remote chassis racks.
Q2: What are the specific power limitations regarding the 32 integrated output points?
A2: Each point supports a continuous current of 0.5 Amps. However, the outputs are clustered into groups of 8 points. The total combined draw for an entire group must not exceed 4.0 Amps, and the return current routed through any individual group common pin must stay below 3.0 Amps to prevent thermal damage.
Q3: What role does the dual-mode master/slave operational feature play in field applications?
A3: Dual-mode operation allows the IC693DNM200 to act simultaneously as a Master node and a Slave device on the same network line. This enables the module to poll localized field sensors (Master mode) while concurrently feeding grouped status metrics upward to a larger supervisory factory controller (Slave mode).
Spesifikasi Tambahan
Skalar (V/f)
Vektor
Dikuasakan oleh AC
Panduan Membeli
- Sahkan model tepat, nombor bahagian, dan spesifikasi sebelum membuat pesanan.
- Pastikan keserasian dengan mesin atau sistem kawalan anda sekarang.
- Hubungi melalui sale@etowonauto.com atau +8617859788089 untuk bantuan teknikal.
- Semak pilihan penghantaran, masa penghantaran, dan keperluan penghantaran.
- Ikuti arahan pengeluar dan amalan terbaik semasa pemasangan.
Penghantaran dan Pemulangan
Barangan yang ada dalam stok biasanya dihantar pada hari perniagaan yang sama. Untuk produk yang tidak tersedia dalam stok, masa penghantaran mungkin berbeza bergantung pada ketersediaan. Penghantaran antarabangsa disediakan, dan kos penghantaran dikira mengikut destinasi, berat, dan pilihan pengangkut.
Pengembalian diterima dalam tempoh 30 hari selepas penerimaan, dengan syarat barangan tidak digunakan dan dalam keadaan asal. Kos penghantaran untuk pengembalian adalah tanggungjawab pelanggan. Sila hubungi kami sebelum memulangkan sebarang barangan untuk mendapatkan kebenaran pengembalian.
Untuk maklumat lanjut, sila semak Polisi Penghantaran & Pengembalian.

3500/61-05-CN Temperature Monitor Module | Bently Nevada
3500/22-01-02-CN TDI Module Bently Nevada
Bently Nevada 3500/42-04-00 | Seismic Monitor
-
Penghantaran Pantas
Alat ganti automasi industri asli tersedia untuk penghantaran segera ke seluruh dunia.
-
Pemulangan Mudah
Sokongan pemulangan selama 30 hari dengan jaminan 12 bulan untuk perlindungan selepas jualan yang boleh dipercayai.
-
Sokongan 24/7
Sokongan profesional responsif untuk membantu mengekalkan operasi yang stabil dan cekap.
-
Asli & Tulen
100% asli, diperoleh terus dari pengeluar automasi industri yang dipercayai.
Panduan Teknikal & Pembelian
-
Why Is Explosion-Proof DCS Critical for Chemical Plant Safety?
This technical article examines how optimized multi-vendor explosion-proof DCS architectures address critical safety ...
-
How to restore Allen‑Bradley PLCs to 99.8% performance?
This technical article presents new, factory-original industrial automation hardware solutions for power plants and p...
-
How to Integrate Cross-Brand DCS and PLC?
This guide delivers field-verified engineering methods for integrating multi-brand DCS and PLC systems. It addresses ...
-
Can Genuine OEM Components Cut Your Automation Downtime by 90%?
This technical brief examines the financial and operational impact of non-genuine automation spare parts across ...
-
How to Solve PLC and DCS Faults in Industrial Automation?
Unplanned downtime in manufacturing is frequently traced to failures in PLC, DCS, and TSI systems, costing medium-siz...
-
How Does ABB System 800xA Enable Cost-Effective DCS Modernization?
This technical article examines a hybrid multi-brand DCS retrofit strategy centered on ABB System 800xA for petrochem...